Comparison of cool tip versus 8-mm tip catheter in achieving electrical isolation of pulmonary veins for long-term control of atrial fibrillation: a prospective randomized pilot study

J Cardiovasc Electrophysiol. 2006 Oct;17(10):1074-9. doi: 10.1111/j.1540-8167.2006.00558.x. Epub 2006 Jul 18.

Abstract

Objective: To compare safety and efficacy of 8-mm versus cooled tip catheter in achieving electrical isolation (EI) of pulmonary veins (PV) for long-term control of atrial fibrillation (AF).

Background: There is paucity of studies comparing safety/efficacy of 8-mm and cooled tip catheters in patients undergoing AF ablation.

Methods and results: This was a randomized and patient-blinded study. Subjects were followed by clinic visits (at 6 weeks and 6 months) and transtelephonic monitoring (3-week duration) done around each visit. Primary endpoints were: (1) long-term AF control (complete freedom and/or >90% reduction in AF burden on or off antiarrhythmic drugs at 6 months after a single ablation), and (2) occurrence of serious adverse events (cardiac tamponade, stroke, LA-esophageal fistula, and/or death). Eighty-two patients (age 56 +/- 9 years, 60 males, paroxysmal AF = 59) were randomized (42 patients to 8-mm tip and 40 patients to cooled tip). EI of PVs was achieved in shorter time by the 8-mm tip as compared with cooled tip catheter (40 +/- 23 minutes vs 50 +/- 30 minutes; P < 0.05) but long-term AF control was not different between the two (32 patients [78%] vs 28 patients [70%], respectively; P = NS). One serious adverse event occurred in each group (LA-esophageal fistula and stroke, respectively) and no significant PV stenosis was observed in either.

Conclusion: EI of PVs using either 8-mm or cooled tip catheter results in long-term AF control in the majority after a single ablation procedure, with comparable efficacy and safety.

Publication types

  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Atrial Fibrillation / diagnosis*
  • Atrial Fibrillation / surgery*
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation
  • Cardiac Catheterization / methods
  • Catheter Ablation / instrumentation*
  • Catheter Ablation / methods
  • Cryotherapy / adverse effects
  • Cryotherapy / instrumentation*
  • Cryotherapy / methods
  • Equipment Design
  • Equipment Failure Analysis
  • Female
  • Humans
  • Longitudinal Studies
  • Male
  • Middle Aged
  • Pilot Projects
  • Pulmonary Veins / surgery*
  • Single-Blind Method
  • Treatment Outcome