Diagnostic accuracy of virtual 18F-FDG PET/CT bronchoscopy for the detection of lymph node metastases in non-small cell lung cancer patients

J Nucl Med. 2011 Oct;52(10):1520-5. doi: 10.2967/jnumed.111.092593. Epub 2011 Sep 9.

Abstract

The aim of this study was to determine the diagnostic accuracy of (18)F-FDG PET/CT bronchoscopy for the detection of regional lymph node metastases in non-small cell lung cancer (NSCLC) patients; potential differences in the maximum standardized uptake value (SUVmax), mean SUV (SUVmean), short-axis diameter, and distance to the airways when comparing true-positive (TP), false-positive (FP), true-negative (TN), and false-negative (FN) lymph nodes; the smallest bronchus diameter accessible by virtual bronchoscopy; and the duration from the start of the virtual (18)F-FDG PET/CT bronchoscopy viewing tool until the images were displayed.

Methods: Sixty-one consecutive NSCLC patients (mean age ± SD, 58 ± 10 y) underwent whole-body (18)F-FDG PET/CT. From these data, virtual (18)F-FDG PET/CT bronchoscopies were reconstructed. The duration from the start of the tool until the display of virtual bronchoscopy images was determined. The diagnostic accuracy of (18)F-FDG PET/CT bronchoscopy for the detection of regional lymph node metastases was evaluated on a lesion basis. Axial (18)F-FDG PET/CT scans served as the standard of reference. The SUVmax, SUVmean, short-axis diameter, and distance to the airways of regional lymph nodes were measured. Lymph nodes were classified as TP, FP, TN, and FN. The smallest bronchus diameter accessible by (18)F-FDG PET/CT bronchoscopy was measured.

Results: The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of virtual (18)F-FDG PET/CT bronchoscopy for the detection of lymph node metastases were 76%, 87%, 85%, 79%, and 81%, respectively. The differences between the SUVmax, SUVmean, short-axis diameter, and distance to the airways of TP and FP as well as TN and FN lymph nodes were statistically significant (P < 0.05). The mean smallest diameter of accessible bronchi by (18)F-FDG PET/CT bronchoscopy was 3 mm. The mean time duration from the start of the virtual (18)F-FDG PET/CT bronchoscopy tool until the display of the images was 22 ± 7 s.

Conclusion: Virtual fly-through 3-dimensional (18)F-FDG PET/CT bronchoscopy yields a high diagnostic accuracy for the detection of regional lymph node metastases and has access to bronchi even in the periphery of the lung. High SUVmax, high SUVmean, large small-axis diameter, and short distance to the airways aid detection of lymph node metastases with (18)F-FDG PET/CT bronchoscopy.

Publication types

  • Evaluation Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Bronchoscopy / methods*
  • Bronchoscopy / statistics & numerical data
  • Carcinoma, Non-Small-Cell Lung / diagnostic imaging*
  • Carcinoma, Non-Small-Cell Lung / secondary*
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Lung Neoplasms / diagnostic imaging*
  • Lymphatic Metastasis / diagnostic imaging*
  • Male
  • Middle Aged
  • Positron-Emission Tomography / methods*
  • Positron-Emission Tomography / statistics & numerical data
  • Predictive Value of Tests
  • Radiopharmaceuticals
  • Retrospective Studies
  • Tomography, X-Ray Computed / methods*
  • Tomography, X-Ray Computed / statistics & numerical data
  • User-Computer Interface*

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18