Transcatheter mitral valve-in-valve implantation in patients with degenerated bioprostheses

JACC Cardiovasc Interv. 2012 Mar;5(3):341-9. doi: 10.1016/j.jcin.2011.12.008.

Abstract

Objectives: This study reports the results of a series of transapical mitral valve-in-valve implantations and aims to offer guidance on technical aspects of the procedure.

Background: Mitral valve reoperations due to failing bioprostheses are associated with high morbidity and mortality. Transcatheter techniques may evolve as complementary approaches to surgery in these high-risk patients.

Methods: Six patients (age 75 ± 15 years) received transapical implantation of a balloon-expandable pericardial heart valve into a degenerated bioprosthesis (range 27 to 31 mm) in mitral position at our institution. All patients were considered high risk for surgical valve replacement (logistic EuroSCORE: 33 ± 15%) after evaluation by an interdisciplinary heart team. Procedural and clinical outcomes were analyzed.

Results: Implantation was successful in all patients with reduction of mean transvalvular gradients from 11.3 ± 5.2 mm Hg to 5.5 ± 3.6 mm Hg (p = 0.016) and median regurgitation from grade 3.0 (interquartile range [IQR]: 2.7 to 3.1) to 0 (IQR: 0 to 1.0, p = 0.033) with trace paravalvular regurgitation remaining in 2 patients. Apical bleeding occurred in 2 patients requiring rethoracotomy in 1 and resuscitation in a second patient, the latter of whom died on postoperative day 6. In the remaining patients, median New York Heart Association functional class improved from 3.0 (IQR: 3.0 to 3.5) to 2.0 (IQR: 1.5 to 2.0, p = 0.048) over a median follow-up of 70 (IQR: 25.5 to 358) days.

Conclusions: With acceptable results in a high-risk population, transapical mitral valve-in-valve implantation can be considered as a complementary approach to reoperative mitral valve surgery in select patients.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Bioprosthesis*
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation*
  • Cardiac Catheterization / mortality
  • Catheterization
  • Female
  • Germany
  • Heart Valve Diseases / surgery*
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Humans
  • Logistic Models
  • Middle Aged
  • Mitral Valve / diagnostic imaging
  • Mitral Valve / surgery*
  • Prosthesis Design
  • Prosthesis Failure*
  • Radiography
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Treatment Outcome
  • Ultrasonography