Paramagnetic perfluorocarbon-filled albumin-(Gd-DTPA) microbubbles for the induction of focused-ultrasound-induced blood-brain barrier opening and concurrent MR and ultrasound imaging

Phys Med Biol. 2012 May 7;57(9):2787-802. doi: 10.1088/0031-9155/57/9/2787. Epub 2012 Apr 18.

Abstract

This paper presents new albumin-shelled Gd-DTPA microbubbles (MBs) that can concurrently serve as a dual-modality contrast agent for ultrasound (US) imaging and magnetic resonance (MR) imaging to assist blood-brain barrier (BBB) opening and detect intracerebral hemorrhage (ICH) during focused ultrasound brain drug delivery. Perfluorocarbon-filled albumin-(Gd-DTPA) MBs were prepared with a mean diameter of 2320 nm and concentration of 2.903×10(9) MBs ml(-1) using albumin-(Gd-DTPA) and by sonication with perfluorocarbon (C(3)F(8)) gas. The albumin-(Gd-DTPA) MBs were then centrifuged and the procedure was repeated until the free Gd(3+) ions were eliminated (which were detected by the xylenol orange sodium salt solution). The albumin-(Gd-DTPA) MBs were also characterized and evaluated both in vitro and in vivo by US and MR imaging. Focused US was used with the albumin-(Gd-DTPA) MBs to induce disruption of the BBB in 18 rats. BBB disruption was confirmed with contrast-enhanced T(1)-weighted turbo-spin-echo sequence MR imaging. Heavy T(2)*-weighted 3D fast low-angle shot sequence MR imaging was used to detect ICH. In vitro US imaging experiments showed that albumin-(Gd-DTPA) MBs can significantly enhance the US contrast in T(1)-, T(2)- and T(2)*-weighted MR images. The r(1) and r(2) relaxivities for Gd-DTPA were 7.69 and 21.35 s(-1)mM(-1), respectively, indicating that the MBs represent a positive contrast agent in T(1)-weighted images. In vivo MR imaging experiments on 18 rats showed that focused US combined with albumin-(Gd-DTPA) MBs can be used to both induce disruption of the BBB and detect ICH. To compare the signal intensity change between pure BBB opening and BBB opening accompanying ICH, albumin-(Gd-DTPA) MB imaging can provide a ratio of 5.14 with significant difference (p = 0.026), whereas Gd-DTPA imaging only provides a ratio of 2.13 and without significant difference (p = 0.108). The results indicate that albumin-(Gd-DTPA) MBs have potential as a US/MR dual-modality contrast agent for BBB opening and differentiating focused-US-induced BBB opening from ICH, and can monitor the focused ultrasound brain drug delivery process.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Albumins / chemistry*
  • Animals
  • Blood-Brain Barrier / diagnostic imaging
  • Blood-Brain Barrier / metabolism*
  • Contrast Media
  • Drug Delivery Systems
  • Feasibility Studies
  • Fluorocarbons / chemistry*
  • Gadolinium DTPA* / chemistry
  • Humans
  • Magnetic Phenomena
  • Magnetic Resonance Imaging / methods*
  • Male
  • Microspheres*
  • Permeability
  • Rats
  • Rats, Sprague-Dawley
  • Ultrasonography / methods*

Substances

  • Albumins
  • Contrast Media
  • Fluorocarbons
  • Gadolinium DTPA