[The application of rhinoscope in microsurgical treatment of intracranial aneurysms intraoperative clinical research]

Zhongguo Yi Liao Qi Xie Za Zhi. 2014 Jul;38(4):312-4.
[Article in Chinese]

Abstract

This paper analysed the rhinoscope's clinical value in microsurgical treatment of intracranial aneurysms. Application of the rhinoscope in 87 patients, only 2 patients had ruptured during operation. However, 11 cases had ruptured in 94 cases without using rhinoscope, P < 0.05, they had a significant difference. By DSA follow-up review, 82 cases of used rhinoscope only 2 cases had remained the aneurysm neck, but 9 cases had the aneurysm neck in 77 cases which had not used the rhinoscope in the microsurgical treatment, P < 0.05, they also had significant difference. The application of rhinoscope in microsurgical treatment of intracranial aneurysms intraoperative, can reduce the risk of the intraoperative aneurysm rupture. It can achieve better clinical effect.

Publication types

  • English Abstract
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Endoscopy*
  • Female
  • Humans
  • Intracranial Aneurysm / surgery*
  • Male
  • Microsurgery
  • Middle Aged
  • Nose / surgery
  • Treatment Outcome