Do Contrast-Fill Patterns Immediately After Coil Embolization of Small Saccular Aneurysms Impact Long-Term Results?

Clin Neuroradiol. 2017 Jun;27(2):205-211. doi: 10.1007/s00062-015-0485-9. Epub 2015 Nov 25.

Abstract

Purpose: It is generally accepted that filling of a saccular aneurysm with contrast immediately after coil embolization predisposes to later recanalization. However, not all such scenarios evolve similarly over time. We investigated outcomes of small (≤ 7 mm) aneurysms with contrast-filled sacs immediately after coil embolization, evaluating the impact of pattern and degree of filling on subsequent recanalization.

Methods: Between January, 2008 and December, 2010, 186 small (≤ 7 mm) saccular aneurysms that retained contrast after coil embolization accrued for this study. Lesions were categorized by pattern (eccentric vs. concentric) and degree of filling on working projections. Clinical and morphologic factors were also analyzed to assess impact on subsequent recanalization. Morphologic outcomes at 6 months or more were assessed.

Results: In 93.5 % (174/186) of aneurysms with visible contrast retention, complete occlusion was evident on follow-up imaging studies at 6 months. Multiple logistic regression analysis indicated that eccentric (vs. concentric) contrast filling carried greater risk of subsequent recanalization (p = 0.020). Stent placement and progressive occlusion were also linked, falling short of statistical significance (p = 0.089). Of 166 progressively occluded aneurysms followed for more than 12 months (mean, 30.8 ± 7.3 months), 158 (95.2 %) exhibited stable occlusion.

Conclusion: Small (≤ 7 mm) aneurysms that retain contrast immediately after coil embolization are more likely to become completely occluded over time through progressive thrombosis. However, an eccentric fill pattern may predispose to recanalization.

Keywords: Aneurysm; Coil; Embolization; Incomplete occlusion; Recanalization.

MeSH terms

  • Cerebral Angiography / methods*
  • Cerebral Arteries / diagnostic imaging*
  • Contrast Media
  • Embolization, Therapeutic / instrumentation
  • Embolization, Therapeutic / methods*
  • Female
  • Humans
  • Intracranial Aneurysm / diagnostic imaging*
  • Intracranial Aneurysm / therapy*
  • Longitudinal Studies
  • Male
  • Mechanical Thrombolysis / instrumentation
  • Mechanical Thrombolysis / methods*
  • Middle Aged
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Treatment Outcome

Substances

  • Contrast Media