Four-year clinical results of transcatheter self-expanding Medtronic CoreValve implantation in high-risk patients with severe aortic stenosis

Age Ageing. 2016 May;45(3):427-30. doi: 10.1093/ageing/afw038. Epub 2016 Mar 24.

Abstract

Background: transcatheter aortic valve implantation (TAVI) has emerged as an alternative to surgical aortic valve replacement for patients with severe aortic stenosis considered inoperable or at high operative risk, but the long-term outcome remains unknown.

Hypothesis: we assessed the 4-year clinical and echocardiographic outcomes of patients undergoing TAVI with the self-expanding Medtronic CoreValve prosthesis.

Methods: sixty-three patients (mean age 80 ± 6 years) with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (Logistic EuroSCORE 28.8 ± 10.9%) were included in this study.

Results: all-cause cumulative mortality at 1, 2, 3 and 4 years was 14.3, 25.4, 28.6 and 36.5%, respectively. The cumulative incidence of documented major stroke at 4 years was 6.3%. In survivors, there was a significant improvement in functional status at 4 years. Paravalvular leak (trivial/mild to moderate) was observed in the majority of patients post-TAVI with no case of progression to severe regurgitation at 4-year follow-up. In multivariate analysis, independent predictor for increased all-cause mortality was left ventricular ejection fraction <40% (HR: 5.347, 95% CI: 1.126-25.381, P = 0.035).

Conclusion: our study demonstrated favourable long-term (4 years) outcomes after successful TAVI using the third-generation Medtronic CoreValve device.

Keywords: TAVI; aortastenosis; older people; outcome.

Publication types

  • Evaluation Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Analysis of Variance
  • Aortic Valve Stenosis / diagnostic imaging*
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / therapy*
  • Bioprosthesis*
  • Cohort Studies
  • Echocardiography / methods
  • Female
  • Follow-Up Studies
  • Frail Elderly
  • Geriatric Assessment
  • Heart Valve Prosthesis*
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Proportional Hazards Models
  • Prosthesis Design
  • Risk Assessment
  • Statistics, Nonparametric
  • Survival Rate
  • Time Factors
  • Transcatheter Aortic Valve Replacement / methods*
  • Transcatheter Aortic Valve Replacement / mortality
  • Treatment Outcome