[Factors influencing electrocardiogram results in workers exposed to noise in steel-making and steel-rolling workshops of an iron and steel plant]

Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2016 Feb 20;34(2):111-4. doi: 10.3760/cma.j.issn.1001-9391.2016.02.008.
[Article in Chinese]

Abstract

Objective: To investigate the factors influencing the electrocardiogram results in the workers exposed to noise in steel-making and steel rolling workshops of an iron and steel plant.

Methods: From September to December, 2013, cluster sampling was used to select 3 150 workers exposed to noise in the steel-making and steel-rolling workshops of an iron and steel plant, and a questionnaire survey and physical examinations were performed. The number of valid workers was 2 915, consisting of 1 606 workers in the steel-rolling workshop and 1 309 in the steel-making workshop. The electrocardiogram results of the workers in steel-making and steel-rolling workshops were analyzed.

Results: The overall abnormal rate of electrocardiogram was 26.35%, and the workers in the steel-making workshop had a significantly higher abnormal rate of electrocardiogram than those in the steel-rolling workshop(32.24% vs 21.54%, P<0.05). Male workers had a significantly higher abnormal rate of electrocardiogram than female workers(27.59% vs 18.61%, P<0.05). The workers with a drinking habit had a significantly higher abnormal rate of electrocardiogram than those who did not drink(28.17% vs 23.75%, P<0.05). The workers exposed to high temperature had a significantly higher abnormal rate of electrocardiogram than those who were not exposed to high temperature(29.43% vs 20.14%, P<0.05). The abnormal rates of electrocardiogram in the workers with cumulative noise exposure levels of <90, 90~94, 95~99, 100~104, and 105~113 dB(A)·year were 21.21%, 21.76%, 26.50%, 27.27%, and 32.16%, respectively, with significant differences between any two groups(P<0.05). The multivariate logistic regression analysis showed that a cumulative noise exposure of 105-113 dB(A)·year(OR=1.36, 95% CI: 1.03~1.80), a drinking habit(OR=1.20, 95% CI: 1.01~1.43), and high temperature(OR=1.60, 95% CI: 1.32~1.92) were the risk factors for abnormal electrocardiogram results.

Conclusion: High cumulative noise exposure, alcohol consumption, and high temperature may affect the abnormal rate of electrocardiogram in the workers exposed to noise in steel-making and steel-rolling workshops.

MeSH terms

  • Alcohol Drinking
  • Electrocardiography
  • Female
  • Humans
  • Iron
  • Male
  • Noise, Occupational*
  • Occupational Exposure*
  • Risk Factors
  • Steel*
  • Surveys and Questionnaires
  • Workplace

Substances

  • Steel
  • Iron