Background: The aim of this study was to evaluate the modified Carba NP test to differentiate KPC (Klebsiella pneumoniae carbapenemase)- and MBL (metallo-β-lactamase)-producing Klebsiella species.
Methods: A total of 508 non-duplicate clinical isolates of Klebsiella spp. were processed by modified Carba NP and combined disc tests which were further confirmed by conventional polymerase chain reaction (PCR), a gold standard method for statistical analysis.
Results: Modified Carba NP test demonstrated 91.7% sensitivity, 100% specificity, 100% positive predictive value (PPV) and 99.8% negative predictive value (NPV) for KPC and 96.7%, 100%, 100%, and 99.5% for MBL detection, respectively.
Conclusion: The performance of modified Carba NP test was significantly better than combined disc test, fulfilling the requirement of simple and rapid test for clinical applications.
Keywords: KPC; MBL; Klebsiella species; carbapenemase; modified Carba NP.
© 2018 Wiley Periodicals, Inc.