[Implementation of NeoKissEs in Spain: A validated surveillance system for nosocomial sepsis in very low birth weight infants]

An Pediatr (Engl Ed). 2019 Jul;91(1):3-12. doi: 10.1016/j.anpedi.2018.06.020. Epub 2018 Sep 24.
[Article in Spanish]

Abstract

Background: Bloodstream infections (BSIs) are the most frequent nosocomial infections in neonatal intensive care units (NICUs), especially in very low birth weight (VLBW) infants (birth weight ≤ 1500g). An epidemiologic surveillance system may contribute to the prevention of infection by continuous monitoring of its frequency and associated risk factors. The aim of this article was to describe the implementation of the NeoKissEs surveillance system for BSIs in VLBW newborns in a group of Spanish NICUs.

Methods: We assessed the clinical cohort consisting of all VLBW newborns aged less than 28 days admitted to the participating units. In the pilot phase, 2NICUs translated and adapted materials from the original German NEO-KISS system. During implementation, 210 health care professionals attended one of 8 educational workshops. A web-based system was created that allows entering data regarding patients and BSI episodes, data monitoring, benchmarking and providing feedback to the units. At each NICU, one neonatologist was responsible for the implementation of the system and reporting the difficulties perceived throughout the process.

Results: Out of the 50 units that agreed to participate, 45 successfully started using the surveillance platform during the implementation phase, recording 1108 episodes of catheter-associated BSI (CABSI) in 3638 newborns, and finding an overall rate of CABSI of 18.4 (95% CI, 17.8-19.1) per 1000 catheter days.

Conclusions: The NeoKissEs surveillance system constitutes a helpful source of information for the purpose of benchmarking the performance of neonatal units, assessing factors associated with BSI in VLBW infants and measuring the impact of future preventive interventions in NICUs.

Keywords: Bacteriemia; Bloodstream infection; Catheter-associated infection; Cuidados intensivos; Infección asociada a catéter; Intensive care; Muy bajo peso; Neonate; Neonato; Nosocomial; Sepsis; Surveillance; Very low birth weight; Vigilancia.

MeSH terms

  • Cross Infection / epidemiology*
  • Epidemiological Monitoring
  • Female
  • Humans
  • Infant, Newborn
  • Infant, Very Low Birth Weight
  • Intensive Care Units, Neonatal / statistics & numerical data*
  • Male
  • Pilot Projects
  • Population Surveillance / methods*
  • Risk Factors
  • Sepsis / epidemiology*
  • Spain / epidemiology