This work proposes an approach for Cu2+ sensing in water which combines the selectivity of the Gly-Gly-His (GGH) peptide probe with the sensitivity of the electrolyte-gated organic field-effect transistor (EGOFET). The oligopeptide probe was immobilized onto the gate electrode of the transistor by electrooxidation of the primary amine of the glycine moiety. Cu2+ complexation by the grafted GGH was at first electrochemically evidenced, using cyclic and square wave voltammetries, then it was demonstrated that GGH-functionalized EGOFETs can transduce Cu2+ complexation through a significant threshold voltage shift and therefore a change in drain current. The limit of detection is ca. 10-12 M and the sensitivity in the linear range (10-12 - 10-8 M) is 1 mA dec-1 (drain current variations).
Keywords: Cu(2+) detection; Electrolyte-Gated Organic Field Effect Transistor; Peptide sensor.
Copyright © 2018 Elsevier B.V. All rights reserved.