Diagnosing posterior tibial tendon tear with dynamic ultrasound following tibial intramedullary nailing

J Clin Orthop Trauma. 2019 Jul-Aug;10(4):666-668. doi: 10.1016/j.jcot.2018.08.015. Epub 2018 Aug 10.

Abstract

Complications following tibial intramedullary nailing include anterior knee pain, malunion, nonunion, and symptomatic/prominent interlocking screws. We report a case of a posterior tibial tendon tear caused by placement of a distal interlocking screw which was detected via dynamic ultrasound. This is a rare and possibly underreported complication which could be the cause of persistent medial sided ankle pain following locked tibial nail placement.

Keywords: Nail; PTT; Tendon; Tibia.

Publication types

  • Case Reports