Characterization of haustral activity in the human colon

Am J Physiol Gastrointest Liver Physiol. 2021 Jun 1;320(6):G1067-G1080. doi: 10.1152/ajpgi.00063.2021. Epub 2021 Apr 28.

Abstract

Contraction patterns of the human colon are rarely discussed from the perspective of its haustra. Colonic motility was analyzed in 21 healthy subjects using 84-sensor manometry catheters with 1-cm sensor spacing. Capsule endoscopy and manometry showed evidence of narrow rhythmic circular muscle contractions. X-ray images of haustra and sensor locations allowed us to identify manometry motor activity as intrahaustral activity. Two common motor patterns were observed that we infer to be associated with individual haustra: rhythmic pressure activity confined to a single sensor, and activity confined to a section of the colon of 3-6 cm length. Intrahaustral activity was observed by 3-4 sensors. Approximately 50% of the haustra were intermittently active for ∼30% of the time; 2,402 periods of haustral activity were analyzed. Intrahaustral activity showed rhythmic pressure waves, propagating in mixed direction, 5-30 mmHg in amplitude at a frequency of ∼3 cpm (range 2-6) or ∼12 cpm (range 7-15), or exhibiting a checkerboard segmentation pattern. Boundaries of the haustra showed rhythmic pressure activity with or without elevated baseline pressure. Active haustra often showed no boundary activity probably allowing transit to neighboring haustra. Haustral boundaries were seen at the same sensor for the 6- to 8-h study duration, indicating that they did not propagate, thereby likely contributing to continence. The present study elucidates the motility characteristics of haustral boundaries and the nature of intrahaustral motor patterns and paves the way for investigating their possible role in pathophysiology of defecation disorders.NEW & NOTEWORTHY Here, we present the first full characterization and quantification of motor patterns that we infer to be confined to single haustra, both intrahaustral activity and haustral boundary activity, in the human colon using high-resolution manometry. Haustral activity is intermittent but consistently present in about half of the haustra. Intrahaustral activity presents as a cyclic motor pattern of mixed propagation direction dominated by simultaneous pressure waves that can resolve into checkerboard segmentation, allowing for mixing, absorption, and stool formation.

Keywords: colon; colonic motility; haustra; high-resolution colonic manometry; interstitial cells of Cajal.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Colon / physiology*
  • Female
  • Gastrointestinal Motility / physiology*
  • Healthy Volunteers
  • Humans
  • Interstitial Cells of Cajal / physiology*
  • Male
  • Manometry
  • Middle Aged
  • Muscle Contraction / physiology
  • Young Adult