Detecting Muscle Invasion of Bladder Cancer Using a Proposed Magnetic Resonance Imaging Strategy

J Magn Reson Imaging. 2021 Oct;54(4):1212-1221. doi: 10.1002/jmri.27676. Epub 2021 May 17.

Abstract

Background: Accurate evaluation of the invasion depth of tumors with a Vesical Imaging-Reporting and Data System (VI-RADS) score of 3 is difficult.

Purpose: To evaluate the diagnostic performance of a new magnetic resonance imaging (MRI) strategy based on the integration of the VI-RADS and tumor contact length (TCL) for the diagnosis of muscle-invasive bladder cancer (MIBC).

Study type: Single center, retrospective.

Subjects: A group of 179 patients with a mean age of 67 years (range, 24.0-96.0) underwent multiparametric MRI (mpMRI) before surgery, including 147 (82.1%) males and 32 (17.9%) females. Twenty-four (13.4%), 90 (50.3%), 43 (24.0%), 15 (8.4%), and 7 (3.9%) cases were Ta, T1, T2, T3, and T4, respectively.

Field strength/sequence: A 1.5 T and 3.0 T, T2-weighted turbo spin-echo (TSE), single-shot echo-planar (SS-EPI), diffusion-weighted imaging (DWI), and T1-weighted volumetric interpolated breath-hold examination (T1-VIBE).

Assessment: Three radiologists independently graded the VI-RADS score and measured the TCL on index lesion images. A proposed MRI strategy called VI-RADS_TCL was introduced by modifying the VI-RADS score, which was downgraded to VI-RADS 3F (equal to a VI-RADS score of 2) if VI-RADS = 3 and TCL < 3 cm.

Statistical tests: Intraclass correlation coefficients (ICCs), Mann-Whitney U test, chi-square tests, receiver operating characteristic (ROC) curves, and 2 × 2 contingency tables were applied.

Results: Inter-reader agreement values were 0.941 (95% CI, 0.924-0.955) and 0.934 (95% CI, 0.916-0.948) for the TCL and VI-RADS score. The TCL was significantly increased in the MIBC group (6.40-6.85 cm) compared with the NMIBC group (1.98-2.45 cm) (P < 0.05). The specificity and positive predictive values (PPV) of VI-RADS_TCL were 82.46%-87.72% and 90.91%-91.59%, which were significantly greater than VI-RADS score (P < 0.05). Additionally, 52.17%-55.88% NMIBC lesions with VI-RADS 3 were downgraded to 3F by using VI-RADS_TCL.

Data conclusion: The proposed MRI strategy could reduce the false-positive rate of lesions with a VI-RADS score of 3 while retaining sensitivity.

Evidence level: 4 TECHNICAL EFFICACY: 2.

Keywords: Vesical Imaging-Reporting and Data System; muscle-invasive bladder cancer; nonmuscle-invasive bladder cancer; tumor contact length.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Humans
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Multiparametric Magnetic Resonance Imaging*
  • Muscles
  • Retrospective Studies
  • Urinary Bladder Neoplasms* / diagnostic imaging
  • Young Adult