Detrimental Immediate- and Medium-Term Clinical Effects of Right Ventricular Pacing in Patients With Myocardial Fibrosis

Circ Cardiovasc Imaging. 2021 May;14(5):e012256. doi: 10.1161/CIRCIMAGING.120.012256. Epub 2021 May 18.

Abstract

Background: Long-term right ventricular (RV) pacing leads to heart failure or a decline in left ventricular (LV) function in up to a fifth of patients. We aimed to establish whether patients with focal fibrosis detected on late gadolinium enhancement cardiovascular magnetic resonance (CMR) have deterioration in LV function after RV pacing.

Methods: We recruited 84 patients with LV ejection fraction ≥40% into 2 observational CMR studies. Patients (n=34) with a dual-chamber device and preserved atrioventricular conduction underwent CMR in 2 asynchronous pacing modes (atrial asynchronous and dual-chamber asynchronous) to compare intrinsic atrioventricular conduction with forced RV pacing. Patients (n=50) with high-grade atrioventricular block underwent CMR before and 6 months after pacemaker implantation to investigate the medium-term effects of RV pacing.

Results: The key findings were (1) initiation of RV pacing in patients with fibrosis, compared with those without, was associated with greater immediate changes in both LV end-systolic volume index (5.3±3.5 versus 2.1±2.4 mL/m2; P<0.01) and LV ejection fraction (-5.7±3.4% versus -3.2±2.6%; P=0.02); (2) medium-term RV pacing in patients with fibrosis, compared with those without, was associated with greater changes in LV end-systolic volume index (8.0±10.4 versus -0.6±7.3 mL/m2; P=0.008) and LV ejection fraction (-12.3±7.9% versus -6.7±6.2%; P=0.012); (3) patients with fibrosis did not experience an improvement in quality of life, biomarkers, or functional class after pacemaker implantation; (4) after 6 months of RV pacing, 10 of 50 (20%) patients developed LV ejection fraction <35% and were eligible for upgrade to cardiac resynchronization according to current guidelines. All 10 patients had fibrosis on their preimplant baseline scan and were identified by >1.1 g of fibrosis with 90% sensitivity and 70% specificity.

Conclusions: Fibrosis detected on CMR is associated with immediate- and medium-term deterioration in LV function following RV pacing and could be used to identify those at risk of heart failure before pacemaker implantation.

Keywords: atrioventricular block; biomarkers; fibrosis; heart failure; heart ventricles.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Cardiac Pacing, Artificial / methods*
  • Cardiomyopathies / diagnosis
  • Cardiomyopathies / physiopathology
  • Cardiomyopathies / therapy*
  • Electrocardiography
  • Fibrosis / diagnosis
  • Fibrosis / drug therapy
  • Fibrosis / physiopathology
  • Follow-Up Studies
  • Humans
  • Magnetic Resonance Imaging, Cine / methods
  • Male
  • Middle Aged
  • Myocardium / pathology*
  • Retrospective Studies
  • Time Factors
  • Treatment Outcome
  • Ventricular Function, Right / physiology*