Limitation of standard ECG criteria to localize an outflow tract PVC

J Electrocardiol. 2021 Sep-Oct:68:124-129. doi: 10.1016/j.jelectrocard.2021.08.012. Epub 2021 Aug 14.

Abstract

Multiple ECG algorithms exist to localize outflow tract PVCs. They can be invaluable in pre-procedure planning and patient counseling. We describe a case where the published algorithm for PVC localization did not predict the site of origin and successful ablation site. This case highlights the strengths and limitations of established ECG PVC localization algorithms.

Keywords: Electrocardiogram (ECG); Outflow tract PVC; Radiofrequency ablation.

Publication types

  • Review

MeSH terms

  • Algorithms
  • Catheter Ablation*
  • Electrocardiography
  • Humans
  • Ventricular Premature Complexes* / diagnosis
  • Ventricular Premature Complexes* / surgery