Kissing Balloon "Valvuloplasty" of Obstructed Mechanical Aortic Valve: When You Are Running Out of Options

JACC Case Rep. 2022 Jul 6;4(13):799-801. doi: 10.1016/j.jaccas.2022.04.003.

Abstract

We report an unusual case where "stuck" bileaflet aortic prosthetic valve occluders were partly released by performing emergency balloon dilatation with 2 noncompliant balloons by a percutaneous femoral approach. (Level of Difficulty: Advanced.).

Keywords: AVR, aortic valve replacement; EF, ejection fraction; LV, left ventricular; MVR, mitral valve replacement; mechanical valves; obstructed occluders; pannus; t-PA, tissue-type plasminogen activator.