Predictors of peri-implant bone remodeling outcomes after the osteotome sinus floor elevation: a retrospective study

BMC Oral Health. 2022 Dec 20;22(1):622. doi: 10.1186/s12903-022-02592-6.

Abstract

Background: This study aimed to evaluate the radiographic outcomes of implants after osteotome sinus floor elevation (OSFE), and further identify the separate predictors for these radiographic outcomes.

Methods: In this retrospective cohort study, a total of 187 implants were inserted into 138 patients using the OSFE technique. Seventy-four patients in the grafted group, and 64 patients in the non-grafted group completed this study. The vertical bone gain (VBG) and marginal bone loss (MBL) at 3 years following surgery were assessed as outcome variables. Based on extensive literature results, variables considered potential predictors of outcome variables included sex, age, tooth position, implant length, implant diameter, with or without grafting materials, residual bone height, sinus width, bone density, and sinus membrane thickness. Subsequently, the binary logistic regression analysis was applied with VBG and MBL as dependent variables, respectively. The receiver operating characteristic curve (ROC) with its area under the curve (AUC) was performed to further determine the predictive value of these predictors.

Results: One hundred and six implants in grafted group and 81 implants in the non-grafted group were analyzed. The average VBG was 2.12 ± 1.94 mm for the grafted group and 0.44 ± 1.01 mm for the non-grafted group at 3 years (P < 0.05). The mean MBL was 1.54 ± 1.42 mm for the grafted group and 1.13 ± 1.69 mm for the non-grafted group at 3 years (P > 0.05). After the adjustment for confounders, logistic regression analysis demonstrated that implant length, grafting, residual bone height, and sinus membrane thickness were predictors of VBG. The odds ratio for VBG was 3.90, 4.04, 4.13 and 2.62, respectively. Furthermore, grafting exhibited the largest AUC at 0.80. While tooth position and implant length were predictors of MBL, the odds ratio for MBL was 3.27 and 7.85, respectively. Meanwhile, implant length exhibited the largest AUC at 0.72.

Conclusions: OSFE with or without simultaneous grafting materials both showed predictable clinical outcomes. Additionally, the present study is the first quantitative and significant verification that VBG has a significant association with sinus membrane thickness, as well as residual bone height, implant length and grafting. Whereas tooth position and implant length are markedly associated with MBL.

Keywords: Implant length; Marginal bone loss; Osteotome sinus floor elevation; Residual bone height; Sinus membrane thickness; Vertical bone gain.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Bone Remodeling
  • Dental Implantation, Endosseous / methods
  • Dental Implants*
  • Humans
  • Maxilla / surgery
  • Maxillary Sinus / surgery
  • Retrospective Studies
  • Sinus Floor Augmentation* / methods
  • Treatment Outcome

Substances

  • Dental Implants