Molecular detection of human Plasmodium species using a multiplex real time PCR

Sci Rep. 2023 Jul 14;13(1):11388. doi: 10.1038/s41598-023-38621-9.

Abstract

Molecular detection methods have revealed higher sensitivity and specificity than conventional microscopy or rapid diagnostic tests for malaria diagnosis. In this study, we implemented, evaluated and validated according to the ISO 15,189 requirements, a multiplex real-time PCR assay to detect and identify the five human malaria parasites. DNA samples were extracted from whole blood or dried blood spots drawn from patients. Based on the External Quality Assessment (whole blood), this method shows 100% sensitivity and specificity. This PCR detected P. vivax up to 0.25 p/µl, P. falciparum and P. knowlesi up to 0.5 p/µl, P. ovale up to 1 p/µl and P. malariae up to 5 p/µl of blood. From blood spots (extraction from four punches), it detected P. vivax at 5 p/µl, P. falciparum, P. ovale and P. knowlesi at 20 p/µl and P. malariae at 125 p/µl. In conclusion, this quantitative PCR shows excellent performance, is easy to use and DNA saver. It is especially useful to actively screen large population groups and identify the five human malaria parasites in a context of low malaria transmission.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Humans
  • Malaria* / parasitology
  • Malaria, Falciparum*
  • Malaria, Vivax* / parasitology
  • Plasmodium falciparum / genetics
  • Plasmodium vivax / genetics
  • Plasmodium* / genetics
  • Real-Time Polymerase Chain Reaction / methods
  • Sensitivity and Specificity