Determination of 11 Kinds of Hair Dyes in Hair-Dyeing Products by Liquid Chromatography-Tandem Mass Spectrometry

J Chromatogr Sci. 2023 Aug 26:bmad071. doi: 10.1093/chromsci/bmad071. Online ahead of print.

Abstract

Eleven kinds of hair dyes were determined in hair-dyeing products by liquid chromatography-tandem mass spectrometry (MS). The samples were extracted with ultrasound in methanol for 20 min. After centrifugation, the supernatant was diluted with 10% methanol/90% water (v/v). Then, the solution was analyzed by Shim-pack Scepter C18-120 column (100 mm × 2.1 mm, 1.9 μm) plus electrospray ionization-MS/MS. Matrix-matched standard solutions were used to analyze the samples. The limits of detection were from 0.15 to 10 mg/kg, the limits of quantification were from 0.5 to 40 mg/kg and the recovery was from 79.4 to 109.2%. The protocol was selective and accurate and was satisfyingly applied to analyze hair dyes in different kinds of commercial products. 1-Hydroxyethyl-4,5-diaminopyrazole sulfate, hydroxyethyl-p-phenylenediamine sulfate, 2-methyl-5-hydroxyethylaminophenol, 5-amino-6-chloro-o-cresol, 3-nitro-p-hydroxyethylaminophenol and 2-amino-6-chloro-4-nitrophenol were detected in 10 samples with the concentrations between limits of detection and quantification to 9.27 × 104 mg/kg.