Impact of Inner Layer Renorrhaphy Suture on Renal Artery Pseudoaneurysm Formation Following Robotic-assisted Partial Nephrectomy

Urology. 2023 Dec:182:125-132. doi: 10.1016/j.urology.2023.06.040. Epub 2023 Sep 4.

Abstract

Objective: To report the impact of resection base inner layer renorrhaphy suture type on renal artery pseudoaneurysm (RAP) rate following robotic-assisted partial nephrectomy (RAPN).

Methods: Five hundred and sixty-three consecutive RAPNs performed by a single surgeon were retrospectively reviewed. Patients were classified into 3 categories: (1) No base suture, (2) monofilament barbed suture (2-0 V-Loc 180 absorbable suture, Medtronic, Minneapolis, MN), (3) polyglactin 910 (2-0 Vicryl coated suture, Ethicon Inc, Cincinnati, OH). In a secondary analysis, we evaluated suturing (Vicryl and V-Loc) vs no base suture. All patients had outer cortical renorrhaphy performed with 0-Vicryl suture utilizing the standard sliding clip technique.

Results: One hundred ten patients (19.5%) had V-Loc suturing, 255 patients (45.3%) had Vicryl suturing, and 198 patients (35.2%) had no base suture. Patients had a median age of 62.8years (interquartile range: 53.5-69.7) and median RENAL score was 8 (6-9). Median mass size from preoperative imaging was 3.0 cm (2.5-4.0) for V-Loc, 3.3 cm (2.5-4.2) for Vicryl, and 2.0 cm (1.8-3.0) for no base suture (P < .001). Overall, 21 patients (3.7%) developed a symptomatic postoperative RAP. The rate of RAP was 3.6% (4/110) for V-Loc, 3.9% (10/255) for 2-0 Vicryl, and 3.5% (7/198) for no base suture (P = 1.00). Similarly, the rate of RAP was 3.5% (7/198) for no base suture and 3.8% (14/365) for base suture (P = 1.00).

Conclusion: Utilization of base suture and type of base suture used during RAPN was not predictive of postoperative RAP development.

MeSH terms

  • Aneurysm, False* / etiology
  • Aneurysm, False* / surgery
  • Humans
  • Middle Aged
  • Nephrectomy / adverse effects
  • Nephrectomy / methods
  • Polyglactin 910
  • Renal Artery / surgery
  • Retrospective Studies
  • Robotic Surgical Procedures* / adverse effects
  • Robotic Surgical Procedures* / methods
  • Suture Techniques / adverse effects
  • Sutures / adverse effects

Substances

  • Polyglactin 910