Usefulness of an auditory aid to improve chest compression rate accuracy during cardiopulmonary resuscitation

J Vet Emerg Crit Care (San Antonio). 2023 Nov-Dec;33(6):639-647. doi: 10.1111/vec.13351. Epub 2023 Nov 9.

Abstract

Objective: To assess compression rate accuracy among veterinarians and registered veterinary nurses (RVNs) without and with an audible aid.

Design: Prospective study with use of a canine CPR manikin.

Setting: Small animal teaching hospital.

Subjects: Thirty-six participants (20 veterinarians and 16 RVNs).

Interventions: Each participant completed the first 2-minute cycle of chest compressions without an auditory aid on a canine CPR manikin. Each participant was then randomized to 1 of 3 auditory aid groups (Group B: Bee Gees "Stayin' Alive"; Group Q: Queen "Another One Bites the Dust"; or Group M: traditional metronome) and then completed a second 2-minute cycle of chest compressions with the instruction to synchronize their compression rate with the beat of the auditory aid. An accurate chest compression rate was defined as obtaining a rate between 100 and 120 compressions per minute (cpm).

Measurements and main results: Median number of compressions administered by participants during Cycle 1 for the first minute was 111 (range 88-140) and for the second minute was 107 (range 80-151), with 25 of 36 (69%) participants obtaining an accurate chest compression rate. Median number of compressions administered during Cycle 2 for the first minute was 110 (range 76-125) and for the second minute was 110 (range 72-125), with 34 of 36 participants (94%) obtaining an accurate chest compression rate. Participants were more likely to obtain an accurate chest compression rate when an auditory aid was present compared to without (McNemar's test; P = 0.013). Subgroup analysis suggested the auditory aid was beneficial in Groups Q and M but not Group B (Kruskal-Wallis with Dunn's post hoc testing; P = 0.014, P = 0.0455, and P = 0.5637, respectively).

Conclusions: An auditory aid was associated with improved chest compression rate accuracy. However, as the auditory aid was not beneficial for Group B participants, our findings suggest that some auditory aids are more helpful than others.

Keywords: CPR; high-fidelity simulator; metronome; training.

Publication types

  • Randomized Controlled Trial, Veterinary

MeSH terms

  • Animals
  • Cardiopulmonary Resuscitation* / education
  • Cardiopulmonary Resuscitation* / veterinary
  • Dogs
  • Manikins
  • Pressure
  • Prospective Studies