Heparin-bonded, expanded polytetrafluoroethylene-lined stent graft in the treatment of femoropopliteal artery disease: 1-year results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) trial

J Vasc Interv Radiol. 2013 Feb;24(2):165-73; quiz 174. doi: 10.1016/j.jvir.2012.10.004. Epub 2013 Jan 28.

Abstract

Purpose: To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency.

Materials and methods: In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio< 2.5.

Results: At 12 months, Rutherford category and ankle-brachial index (ABI) were significantly improved (mean category improvement, 2.4; ABI increased from 0.6±0.2 to 0.9±0.19; P<.0001). Primary and secondary patency rates were 73% and 92%. The primary patency for devices oversized<20% at the proximal landing zone was 88%, whereas the primary patency for devices oversized by>20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%.

Conclusions: The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes.

Publication types

  • Clinical Trial
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Anticoagulants / administration & dosage
  • Coated Materials, Biocompatible / chemical synthesis
  • Drug-Eluting Stents*
  • Equipment Design
  • Equipment Failure Analysis
  • Female
  • Femoral Artery / drug effects
  • Femoral Artery / surgery
  • Heparin / administration & dosage*
  • Humans
  • Male
  • Peripheral Arterial Disease / diagnosis
  • Peripheral Arterial Disease / therapy*
  • Polytetrafluoroethylene / chemistry*
  • Popliteal Artery / drug effects
  • Popliteal Artery / surgery
  • Treatment Outcome
  • United States

Substances

  • Anticoagulants
  • Coated Materials, Biocompatible
  • Polytetrafluoroethylene
  • Heparin