Search Results

4 results

Results by year

Filters applied: . Clear all
Page 1
Collagen cross-linking effect on progressive keratoconus in patients younger than 18 years of age: A clinical trial.
Peyman A, Kamali A, Khushabi M, Nasrollahi K, Kargar N, Taghaodi M, Razmjoo H, Fazel F, Salesi A. Peyman A, et al. Adv Biomed Res. 2015 Nov 23;4:245. doi: 10.4103/2277-9175.170240. eCollection 2015. Adv Biomed Res. 2015. PMID: 26693470 Free PMC article.
Maximum keratometry before and after the operation was 53.82 0.72 and 53.33 0.72, respectively (P = 0.018). Differences for simulated K values, the thinnest cornea pachymetry, keratoconus index (KI), index of highest asymmetry (IHA), and index of highest decentration (IHD) …
Maximum keratometry before and after the operation was 53.82 0.72 and 53.33 0.72, respectively (P = 0.018). Differences for simulated K
Corneal haze and visual outcome after collagen crosslinking for keratoconus: A comparison between total epithelium off and partial epithelial removal methods.
Razmjoo H, Rahimi B, Kharraji M, Koosha N, Peyman A. Razmjoo H, et al. Adv Biomed Res. 2014 Nov 29;3:221. doi: 10.4103/2277-9175.145677. eCollection 2014. Adv Biomed Res. 2014. PMID: 25538907 Free PMC article.
However, comparison of pre- and postoperative parameters within each group revealed that total removal of the cornea has resulted in significant improvement of K-max (P value: 0.01) and Q-value (P value: 0.009); while eyes in partial removal group had better improvement of …
However, comparison of pre- and postoperative parameters within each group revealed that total removal of the cornea has resulted in signifi …
Evaluation of chemical and microbiological quality in 21 brands of Iranian bottled drinking waters in 2012: a comparison study on label and real contents.
Moazeni M, Atefi M, Ebrahimi A, Razmjoo P, Vahid Dastjerdi M. Moazeni M, et al. J Environ Public Health. 2013;2013:469590. doi: 10.1155/2013/469590. Epub 2013 Apr 15. J Environ Public Health. 2013. PMID: 23690802 Free PMC article.
The purpose of this study was to evaluate and compare chemical and microbiological quality of the 21 Iranian bottled drinking waters reported on manufacturer's labeling and standards in 2012. Samples were analyzed for chemical properties K(+), F(-), SO4 (2-), Cl(-), Mg(2+) …
The purpose of this study was to evaluate and compare chemical and microbiological quality of the 21 Iranian bottled drinking waters reporte …
A regression model for correcting intraocular lens power after refractive surgery independent of preoperative data.
Razmjoo H, Peyman A, Kashfi A, Peyman M, Dehghani A. Razmjoo H, et al. Eur J Ophthalmol. 2006 Jul-Aug;16(4):525-9. doi: 10.1177/112067210601600404. Eur J Ophthalmol. 2006. PMID: 16952089
RESULTS: A regression model with these predictors was found: axial length in millimeters (L), radius of the anterior corneal surface best fitted sphere in millimeters divided by radius of the posterior corneal surface best fitted sphere in millimeters (AntBFS/PostBFS), corneal ce …
RESULTS: A regression model with these predictors was found: axial length in millimeters (L), radius of the anterior corneal surface best fi …