Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2022 1
2023 3
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

4 results

Results by year

Filters applied: . Clear all
Page 1
Did you mean e moazami n (14 results)?
Accelerated Quantitative 3D UTE-Cones Imaging Using Compressed Sensing.
Athertya JS, Ma Y, Masoud Afsahi A, Lombardi AF, Moazamian D, Jerban S, Sedaghat S, Jang H. Athertya JS, et al. Sensors (Basel). 2022 Oct 1;22(19):7459. doi: 10.3390/s22197459. Sensors (Basel). 2022. PMID: 36236557 Free PMC article.
Percentage errors between fully sampled and undersampled CS-reconstructed images were below 5% for up to 50% undersampling (i.e., 2 acceleration). High linear correlation was observed (>0.95) for all qUTE parameters estimated in all subjects. ...
Percentage errors between fully sampled and undersampled CS-reconstructed images were below 5% for up to 50% undersampling (i.e., 2 a …
Detection of iron oxide nanoparticle (IONP)-labeled stem cells using quantitative ultrashort echo time imaging: a feasibility study.
Athertya JS, Akers J, Sedaghat S, Wei Z, Moazamian D, Dwek S, Thu M, Jang H. Athertya JS, et al. Quant Imaging Med Surg. 2023 Feb 1;13(2):585-597. doi: 10.21037/qims-22-654. Epub 2023 Jan 9. Quant Imaging Med Surg. 2023. PMID: 36819276 Free PMC article.
The phantom was imaged with quantitative UTE (qUTE) MR techniques [i.e., UTE-T(1) mapping, UTE-T(2)* mapping, and UTE-based quantitative susceptibility mapping (UTE-QSM)] as well as with a clinical T(2) mapping sequence on a 3T clinical MR system. ...
The phantom was imaged with quantitative UTE (qUTE) MR techniques [i.e., UTE-T(1) mapping, UTE-T(2)* mapping, and UTE-based quantitat …
Whole knee joint mapping using a phase modulated UTE adiabatic T (PM-UTE-AdiabT ) sequence.
Ma Y, Carl M, Tang Q, Moazamian D, Athertya JS, Jang H, Bukata SV, Chung CB, Chang EY, Du J. Ma Y, et al. Magn Reson Med. 2024 Mar;91(3):896-910. doi: 10.1002/mrm.29871. Epub 2023 Sep 27. Magn Reson Med. 2024. PMID: 37755319 Free PMC article.
METHODS: This new sequence includes six major features: (1) a magnetization reset module, (2) a train of adiabatic full passage pulses for spin locking, (3) a phase modulation scheme (i.e., RF cycling pair), (4) a fat saturation module, (5) a variable flip angle scheme, an …
METHODS: This new sequence includes six major features: (1) a magnetization reset module, (2) a train of adiabatic full passage pulses for s …
Quantitative myelin water imaging using short TR adiabatic inversion recovery prepared echo-planar imaging (STAIR-EPI) sequence.
Shaterian Mohammadi H, Moazamian D, Athertya JS, Shin SH, Lo J, Suprana A, Malhi BS, Ma Y. Shaterian Mohammadi H, et al. Front Radiol. 2023 Sep 28;3:1263491. doi: 10.3389/fradi.2023.1263491. eCollection 2023. Front Radiol. 2023. PMID: 37840897 Free PMC article.
METHODS: Myelin water (MW) in the brain has shorter T(1) and T(2) relaxation times than intracellular and extracellular water. In the proposed STAIR-EPI sequence, a short TR (e.g., 300 ms) together with an optimized inversion time enable robust long T(1) water suppression …
METHODS: Myelin water (MW) in the brain has shorter T(1) and T(2) relaxation times than intracellular and extracellular water. In the propos …