Search Page
Save citations to file
Email citations
Send citations to clipboard
Add to Collections
Add to My Bibliography
Create a file for external citation management software
Your saved search
Your RSS Feed
Filters
Results by year
Table representation of search results timeline featuring number of search results per year.
Year | Number of Results |
---|---|
2015 | 1 |
2016 | 1 |
2018 | 2 |
2019 | 1 |
2024 | 0 |
Search Results
3 results
Results by year
Filters applied: . Clear all
Page 1
Evaluation of bioprosthetic heart valve failure using a matrix-fibril shear stress transfer approach.
J Mater Sci Mater Med. 2016 Feb;27(2):42. doi: 10.1007/s10856-015-5657-2. Epub 2015 Dec 29.
J Mater Sci Mater Med. 2016.
PMID: 26715134
It is shown that the required critical fibril length to provide effective reinforcement to the natural AV and the BHV tissue is l c = 25.36 m and l c = 66.81 m, respectively. Furthermore, the magnitude of the required shear force acting on fibril interface to break …
It is shown that the required critical fibril length to provide effective reinforcement to the natural AV and the BHV tissue is l c = 25.36 …
Organic acid concentration thresholds for ageing of carbonate minerals: Implications for CO2 trapping/storage.
Ali M, Al-Anssari S, Arif M, Barifcani A, Sarmadivaleh M, Stalker L, Lebedev M, Iglauer S.
Ali M, et al.
J Colloid Interface Sci. 2019 Jan 15;534:88-94. doi: 10.1016/j.jcis.2018.08.106. Epub 2018 Aug 30.
J Colloid Interface Sci. 2019.
PMID: 30216836
FINDINGS: These thresholds (defined for structural trapping as a water contact angle teta > 90; and for capillary trapping when primary drainage is unaffected, i.e. teta > 50) were very low for structural trapping (10(-3)-10(-7) M organic acid concentration C(organic …
FINDINGS: These thresholds (defined for structural trapping as a water contact angle teta > 90; and for capillary trapping when primary d …
Item in Clipboard
Impact of nanoparticles on the CO2-brine interfacial tension at high pressure and temperature.
Al-Anssari S, Barifcani A, Keshavarz A, Iglauer S.
Al-Anssari S, et al.
J Colloid Interface Sci. 2018 Dec 15;532:136-142. doi: 10.1016/j.jcis.2018.07.115. Epub 2018 Jul 27.
J Colloid Interface Sci. 2018.
PMID: 30077827
Hence, CO(2)/brine gamma has low, but, reasonable values (higher than 20 mN/m) at carbon storage conditions even with the presence of hydrophilic NPs, therefore, CO(2) storage can be considered in oil reservoirs after flooding with hydrophilic nanofluid. ...
Hence, CO(2)/brine gamma has low, but, reasonable values (higher than 20 mN/m) at carbon storage conditions even with the presence of …
Item in Clipboard
Cite
Cite