Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1970 1
1975 2
1976 5
1977 1
1978 5
1979 1
1980 6
1981 5
1982 5
1983 5
1984 6
1985 2
1986 5
1987 7
1988 2
1989 11
1990 16
1991 12
1992 9
1993 9
1994 11
1995 14
1996 25
1997 11
1998 28
1999 24
2000 34
2001 35
2002 35
2003 51
2004 41
2005 70
2006 72
2007 82
2008 101
2009 130
2010 132
2011 129
2012 138
2013 179
2014 188
2015 217
2016 218
2017 223
2018 262
2019 294
2020 425
2021 501
2022 539
2023 559
2024 302

Text availability

Article attribute

Article type

Publication date

Search Results

4,544 results

Results by year

Filters applied: . Clear all
Page 1
Interimplant femoral fractures.
Bonnomet F, Favreau H, Bonnevialle P, Adam P, Ehlinger M. Bonnomet F, et al. Orthop Traumatol Surg Res. 2022 Feb;108(1S):103117. doi: 10.1016/j.otsr.2021.103117. Epub 2021 Oct 16. Orthop Traumatol Surg Res. 2022. PMID: 34666198 Free article. Review.
Interprosthetic femoral fractures: management challenges.
Rozell JC, Delagrammaticas DE, Schwarzkopf R. Rozell JC, et al. Orthop Res Rev. 2019 Sep 16;11:119-128. doi: 10.2147/ORR.S209647. eCollection 2019. Orthop Res Rev. 2019. PMID: 31572021 Free PMC article. Review.
Research Update on Stress Riser Fractures.
Yoo J, Ma X, Lee J, Hwang J. Yoo J, et al. Indian J Orthop. 2020 Nov 25;55(3):560-570. doi: 10.1007/s43465-020-00291-4. eCollection 2021 Jun. Indian J Orthop. 2020. PMID: 33995860 Free PMC article. Review.
Periprosthetic fractures about total knee arthroplasty.
Lombardo DJ, Siljander MP, Sobh A, Moore DD, Karadsheh MS. Lombardo DJ, et al. Musculoskelet Surg. 2020 Aug;104(2):135-143. doi: 10.1007/s12306-019-00628-9. Epub 2019 Oct 23. Musculoskelet Surg. 2020. PMID: 31643045 Review.
Periprosthetic fracture after total knee arthroplasty presents a difficult complication for many orthopaedic surgeons. ...
Periprosthetic fracture after total knee arthroplasty presents a difficult complication for many orthopaedic surgeons. ...
Periprosthetic fractures: bespoke solutions.
Yasen AT, Haddad FS. Yasen AT, et al. Bone Joint J. 2014 Nov;96-B(11 Supple A):48-55. doi: 10.1302/0301-620X.96B11.34300. Bone Joint J. 2014. PMID: 25381408 Free article. Review.
Problems in plating periprosthetic femur fractures.
Schmidt AH. Schmidt AH. Injury. 2018 Jun;49 Suppl 1:S49-S50. doi: 10.1016/S0020-1383(18)30303-6. Injury. 2018. PMID: 29929693 Review.
However, fractures may occur adjacent to a previous internal fixation device used to treat a prior fracture in the same patient, or between implants (the interprosthetic fracture). All of these injuries tend to occur in frail patients with severe osteopenia, and the …
However, fractures may occur adjacent to a previous internal fixation device used to treat a prior fracture in the same patient, or between …
The management of complex periprosthetic fractures.
Melnic CM, Paprosky WG. Melnic CM, et al. Arthroplast Today. 2016 Oct 18;2(4):139-140. doi: 10.1016/j.artd.2016.09.011. eCollection 2016 Dec. Arthroplast Today. 2016. PMID: 28326417 Free PMC article. No abstract available.
Stress Concentration Analysis of the Corroded Steel Plate Strengthened with Carbon Fiber Reinforced Polymer (CFRP) Plates.
Li A, Wang H, Li H, Kong D, Xu S. Li A, et al. Polymers (Basel). 2022 Sep 14;14(18):3845. doi: 10.3390/polym14183845. Polymers (Basel). 2022. PMID: 36145986 Free PMC article.
The purpose of this study is to investigate the stress concentration of a corroded steel plate strengthened with carbon fiber reinforced polymer (CFRP) plates. ...The value of K(t) for the corroded steel plate with a corrosion duration of 6~18 months and a weight lo …
The purpose of this study is to investigate the stress concentration of a corroded steel plate strengthened with carbon fiber …
Periprosthetic fractures following total knee arthroplasty.
Yoo JD, Kim NK. Yoo JD, et al. Knee Surg Relat Res. 2015 Mar;27(1):1-9. doi: 10.5792/ksrr.2015.27.1.1. Epub 2015 Mar 2. Knee Surg Relat Res. 2015. PMID: 25750888 Free PMC article. Review.
Periprosthetic fractures around the knee should be prevented by appropriate technique during total knee arthroplasty. Nevertheless, if a periprosthetic fracture occurs, an appropriate treatment method should be selected considering the stability of the prosthesis, d …
Periprosthetic fractures around the knee should be prevented by appropriate technique during total knee arthroplasty. Nevertheless, if a …
4,544 results