Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1998 1
1999 1
2000 1
2001 3
2004 1
2005 2
2006 2
2012 1
2016 1
2018 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

14 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Abnormal static perimetry test"
Page 1
Automated static perimetry: the influence of myopia and its method of correction.
Aung T, Foster PJ, Seah SK, Chan SP, Lim WK, Wu HM, Lim AT, Lee LL, Chew SJ. Aung T, et al. Ophthalmology. 2001 Feb;108(2):290-5. doi: 10.1016/s0161-6420(00)00497-8. Ophthalmology. 2001. PMID: 11158801
OBJECTIVE: To determine how the magnitude of myopia and its method of correction influence visual field testing. DESIGN: Prospective observational case series, including comparison of spectacles and contact lenses. ...CONCLUSIONS: Threshold sensitivity is red …
OBJECTIVE: To determine how the magnitude of myopia and its method of correction influence visual field testing. DESIGN
Perimetric and retinal nerve fiber layer findings in patients with Parkinson's disease.
Tsironi EE, Dastiridou A, Katsanos A, Dardiotis E, Veliki S, Patramani G, Zacharaki F, Ralli S, Hadjigeorgiou GM. Tsironi EE, et al. BMC Ophthalmol. 2012 Oct 2;12:54. doi: 10.1186/1471-2415-12-54. BMC Ophthalmol. 2012. PMID: 23031247 Free PMC article.
The aim of this study is to compare visual field (VF) findings and circumpapillary retinal nerve fiber layer (RNFL) thickness in a series of PD patients and normal controls, in order to assess possible retinal anatomical changes and/or functional damage associated w …
The aim of this study is to compare visual field (VF) findings and circumpapillary retinal nerve fiber layer (RNFL) thickness …
Efficacy Outcome Measures for Clinical Trials of USH2A Caused by the Common c.2299delG Mutation.
Calzetti G, Levy RA, Cideciyan AV, Garafalo AV, Roman AJ, Sumaroka A, Charng J, Heon E, Jacobson SG. Calzetti G, et al. Am J Ophthalmol. 2018 Sep;193:114-129. doi: 10.1016/j.ajo.2018.06.017. Epub 2018 Jun 25. Am J Ophthalmol. 2018. PMID: 29953849
METHODS: Eighteen patients, homozygotes or compound heterozygotes with the c.2299delG mutation in USH2A, were studied with regard to visual acuity, kinetic perimetry, dark- and light-adapted static perimetry, optical coherence tomography (OCT), and aut …
METHODS: Eighteen patients, homozygotes or compound heterozygotes with the c.2299delG mutation in USH2A, were studied with regard to visu
Feasibility and outcome of automated static perimetry in children using continuous light increment perimetry (CLIP) and fast threshold strategy.
Wabbels BK, Wilscher S. Wabbels BK, et al. Acta Ophthalmol Scand. 2005 Dec;83(6):664-9. doi: 10.1111/j.1600-0420.2005.00526.x. Acta Ophthalmol Scand. 2005. PMID: 16396642 Free article.
For that reason new testing strategies for automated perimetry have mainly been evaluated on adults. We tested the feasibility and outcome of automated static perimetry in children in a standard clinical setting. ...Fast threshold strategy (FT) and con …
For that reason new testing strategies for automated perimetry have mainly been evaluated on adults. We tested the feasibility and ou …
Comparison of central and peripheral visual field properties in the optic neuritis treatment trial.
Keltner JL, Johnson CA, Spurr JO, Beck RW. Keltner JL, et al. Am J Ophthalmol. 1999 Nov;128(5):543-53. doi: 10.1016/s0002-9394(99)00304-9. Am J Ophthalmol. 1999. PMID: 10577521 Clinical Trial.
PURPOSE: To compare the results of peripheral kinetic visual field testing and central static perimetry for patients enrolled in the Optic Neuritis Treatment Trial to determine (1) whether loss and recovery of visual field sensitiv …
PURPOSE: To compare the results of peripheral kinetic visual field testing and central static perimetry for pati …
Diagnostic methods in ocular argyrosis: case report.
Sarnat-Kucharczyk M, Pojda-Wilczek D, Mrukwa-Kominek E. Sarnat-Kucharczyk M, et al. Doc Ophthalmol. 2016 Oct;133(2):129-138. doi: 10.1007/s10633-016-9552-z. Epub 2016 Jul 8. Doc Ophthalmol. 2016. PMID: 27392933 Free PMC article.
METHODS: A complete eye examination, corneal confocal microscopy, kinetic and static visual field test, posterior segment optical coherent tomography, pattern visual evoked potentials (PVEP), flash visual evoked potentials, multifocal ele …
METHODS: A complete eye examination, corneal confocal microscopy, kinetic and static visual field test, posterio …
Nephropathic cystinosis: posterior segment manifestations and effects of cysteamine therapy.
Tsilou ET, Rubin BI, Reed G, Caruso RC, Iwata F, Balog J, Gahl WA, Kaiser-Kupfer MI. Tsilou ET, et al. Ophthalmology. 2006 Jun;113(6):1002-9. doi: 10.1016/j.ophtha.2005.12.026. Epub 2006 Apr 17. Ophthalmology. 2006. PMID: 16603246
METHODS: All patients underwent an ophthalmic evaluation. Patients older than 11 years also underwent Humphrey static perimetry, and electrophysiological testing was performed when possible. MAIN OUTCOME MEASURES: Visual acuity, retina findings, visual
METHODS: All patients underwent an ophthalmic evaluation. Patients older than 11 years also underwent Humphrey static perimetry
The reliability of frequency-doubling perimetry in young children.
Blumenthal EZ, Haddad A, Horani A, Anteby I. Blumenthal EZ, et al. Ophthalmology. 2004 Mar;111(3):435-9. doi: 10.1016/j.ophtha.2003.06.018. Ophthalmology. 2004. PMID: 15019315
OBJECTIVE: To evaluate whether healthy young children are able to perform automated static perimetry reliably using the frequency-doubling technology (FDT) perimeter. ...TESTING: Subjects underwent, in 1 randomly chosen eye, 2 consecutive visual fie
OBJECTIVE: To evaluate whether healthy young children are able to perform automated static perimetry reliably using the freque …
Optic disk ovality as an index of tilt and its relationship to myopia and perimetry.
Tay E, Seah SK, Chan SP, Lim AT, Chew SJ, Foster PJ, Aung T. Tay E, et al. Am J Ophthalmol. 2005 Feb;139(2):247-52. doi: 10.1016/j.ajo.2004.08.076. Am J Ophthalmol. 2005. PMID: 15733984
PURPOSE: To examine the association of optic disk ovality with myopic refractive error, axial length, and the visual field. DESIGN: Prospective observational case series. METHODS: The study included 150 randomly recruited male subjects with myopia. ... …
PURPOSE: To examine the association of optic disk ovality with myopic refractive error, axial length, and the visual field. …
Visual electrophysiological effect of a GABA transaminase blocker.
Harding GF, Robertson KA, Edson AS, Barnes P, Wild J. Harding GF, et al. Doc Ophthalmol. 1998-1999;97(2):179-88. doi: 10.1023/a:1002045223358. Doc Ophthalmol. 1998. PMID: 10765970 Clinical Trial.
The anticonvulsant effect is achieved by irreversible inhibition of the enzyme GABA-transaminase which catalyses the inactivation of GABA. Vigabatrin has been associated with visual field loss and electrophysiological abnormalities. The purpose of the study w …
The anticonvulsant effect is achieved by irreversible inhibition of the enzyme GABA-transaminase which catalyses the inactivation of GABA. V …
14 results