Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1977 1
1995 1
1996 1
1997 2
1998 2
2000 1
2001 2
2002 4
2003 2
2004 6
2005 2
2006 7
2007 5
2008 7
2009 6
2010 6
2011 5
2012 8
2013 8
2014 8
2015 4
2016 7
2017 6
2018 1
2019 1
2020 3
2021 2
2022 7
2023 5
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

102 results

Results by year

Filters applied: . Clear all
Page 1
Outcome comparison of different approaches to aortic root aneurysm.
Gocoł R, Bis J, Malinowski M, Morkisz Ł, Jodłowski M, Darocha T, Ciosek J, Wojakowski W, Deja MA. Gocoł R, et al. Kardiol Pol. 2022;80(4):436-444. doi: 10.33963/KP.a2022.0045. Epub 2022 Feb 13. Kardiol Pol. 2022. PMID: 35152397 Free article.
The median (IQR) aortic valve peak gradient was 9 (6-12) mm Hg, 12 (10-18) mm Hg and 16 (14-22) mm Hg, respectively (P <0.001). Complications were predicted by mechanical Bentall (hazard ratio, 6.70 [2.54-17.63]; P <0.001). ...
The median (IQR) aortic valve peak gradient was 9 (6-12) mm Hg, 12 (10-18) mm Hg and 16 (14-22) mm Hg, respectively (P <0.001). Complicat …
Twenty-five years of root remodelling for root aneurysm and tricuspid aortic valve.
Ehrlich T, Abeln KB, Burgard C, Froede L, Schulze-Berge J, Morgenthaler L, Giebels C, Schäfers HJ. Ehrlich T, et al. Eur J Cardiothorac Surg. 2023 Jun 1;63(6):ezad137. doi: 10.1093/ejcts/ezad137. Eur J Cardiothorac Surg. 2023. PMID: 37040067
Hospital mortality was 2.3%, and survival was 81.7% (SD: 1.2) and 55.7% (SD: 5.8) at 10 and 20 years; age and measurement of effective height were independent predictors for death. Freedom from Aortic insufficiency (AI) II was 90.5 (SD: 1.9) at 10 years and 76.7 (SD: 4.5) …
Hospital mortality was 2.3%, and survival was 81.7% (SD: 1.2) and 55.7% (SD: 5.8) at 10 and 20 years; age and measurement of effective heigh …
Aortic root aneurysm: principles of repair and long-term follow-up.
David TE, Maganti M, Armstrong S. David TE, et al. J Thorac Cardiovasc Surg. 2010 Dec;140(6 Suppl):S14-9; discussion S45-51. doi: 10.1016/j.jtcvs.2010.07.041. J Thorac Cardiovasc Surg. 2010. PMID: 21092781 Free article.
Survival at 12 years was 82.9 3.7% and similar between types of operations. Age and aortic dissection were independent predictors of mortality. Seven patients have had reoperations on the aortic valve: 6 for aortic insufficiency and 1 for endocarditis. ...Freedoms from mod …
Survival at 12 years was 82.9 3.7% and similar between types of operations. Age and aortic dissection were independent predictors of …
David Procedure: A 21-year Experience With 300 Patients.
Manganiello S, Soquet J, Mugnier A, Rousse N, Juthier F, Banfi C, Loobuyck V, Coisne A, Richardson M, Marechaux S, Moussa MD, Robin E, Pinçon C, Prat A, Vincentelli A. Manganiello S, et al. Ann Thorac Surg. 2023 Jun;115(6):1403-1410. doi: 10.1016/j.athoracsur.2022.04.058. Epub 2022 May 26. Ann Thorac Surg. 2023. PMID: 35643333
The aim of this study was to describe our long-term experience with this technique and the predictive factors of late failure. METHODS: Between January 1998 and August 2019, 300 consecutive patients underwent a David procedure. ...Preoperative AI 2 (hazard ratio, 1.782; 95 …
The aim of this study was to describe our long-term experience with this technique and the predictive factors of late failure. METHOD …
Outcome of Pulmonary Autograft After the Ross Procedure.
Nakayama Y, Shinkawa T, Matsumura G, Hoki R, Kobayashi K, Yoshida H, Yamagishi M, Niinami H. Nakayama Y, et al. World J Pediatr Congenit Heart Surg. 2021 Jul;12(4):508-515. doi: 10.1177/21501351211007802. World J Pediatr Congenit Heart Surg. 2021. PMID: 34278861
Aortic valve reimplantation in patients with connective tissue syndromes: A 15-year follow-up.
Forteza Gil A, Martinez-Lopez D, Centeno J, Rivas Oyarzabal J, García Suarez J, de Villarreal Soto JE, Rosado ECR, Vera Puente B, Villar García S, Ospina Mosquera VM, Mingo S, Moñivas V, Serrano-Fiz S, Martínez López D. Forteza Gil A, et al. Eur J Cardiothorac Surg. 2022 Aug 3;62(3):ezac149. doi: 10.1093/ejcts/ezac149. Eur J Cardiothorac Surg. 2022. PMID: 35388902
Fifteen-Year Outcomes Following Valve-Sparing Aortic Root Replacement in Elderly Patients.
Liu Y, Benzha MY, Hubert M, Perin B, Lauria G, Dan P, Phamisith E, Scadi S, Dong N, Villemot JP, Maureira JP. Liu Y, et al. Heart Lung Circ. 2022 Jan;31(1):144-152. doi: 10.1016/j.hlc.2021.07.013. Epub 2021 Aug 28. Heart Lung Circ. 2022. PMID: 34465542
During follow-up, 6.7% of patients were in NYHA class III and 6.4% of patients developed moderate-to-severe aortic regurgitation. Cox regression analysis failed to identify predictors for primary outcomes. CONCLUSION: Valve-sparing aortic root replacement can safely be per …
During follow-up, 6.7% of patients were in NYHA class III and 6.4% of patients developed moderate-to-severe aortic regurgitation. Cox regres …
Aortic Root Biomechanics After Sleeve and David Sparing Techniques: A Finite Element Analysis.
Tasca G, Selmi M, Votta E, Redaelli P, Sturla F, Redaelli A, Gamba A. Tasca G, et al. Ann Thorac Surg. 2017 May;103(5):1451-1459. doi: 10.1016/j.athoracsur.2016.08.003. Epub 2016 Oct 15. Ann Thorac Surg. 2017. PMID: 27756469
RESULTS: Both sparing techniques restored physiologic-like kinematics of aortic valve (AV) leaflets but induced different leaflets stresses. The time course averaged over the leaflets' bellies was 35% higher in the David model than in the Sleeve model. ...
RESULTS: Both sparing techniques restored physiologic-like kinematics of aortic valve (AV) leaflets but induced different leaflets stresses. …
102 results