Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1976 1
1984 1
1997 2
2000 2
2003 1
2005 1
2007 1
2008 3
2009 1
2010 1
2011 2
2012 1
2016 1
2017 1
2018 1
2019 1
2021 2
2022 2
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

20 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Constricted radius"
Page 1
High dose-rate brachytherapy for the treatment of lower extremity in-stent restenosis.
Ho KJ, Devlin PM, Madenci AL, Semel ME, Gravereaux EC, Nguyen LL, Belkin M, Menard MT. Ho KJ, et al. J Vasc Surg. 2017 Mar;65(3):734-743. doi: 10.1016/j.jvs.2016.10.002. Epub 2016 Dec 13. J Vasc Surg. 2017. PMID: 27986482 Free article.
METHODS: This is a retrospective, single-center review of patients treated with PTA and EVBT for ISR in the iliac and femoropopliteal segments between 2004 and 2012. A dose of 20 Gy was given at a depth of 0.5 mm beyond the radius of the largest PTA balloon using iridium 1 …
METHODS: This is a retrospective, single-center review of patients treated with PTA and EVBT for ISR in the iliac and femoropopliteal segmen …
Association of residual stenosis after balloon angioplasty with vessel wall geometries in intracranial atherosclerosis.
Hou Z, Zhang Z, Yan L, You J, Wan M, Song J, Pan Y, Hui F, Miao Z, Lou X, Wang Y, Jing J, Ma N. Hou Z, et al. J Neurointerv Surg. 2022 Aug;14(8):762-766. doi: 10.1136/neurintsurg-2021-017997. Epub 2021 Sep 1. J Neurointerv Surg. 2022. PMID: 34470789
Vessel wall geometries of the target artery, including normalized wall index (NWI: wall area/vessel area 100%), normalized wall thickness index (NWTI: mean wall thickness/vessel radius 100%), and remodeling index (RI) were evaluated. Low residual stenosis was defined as po …
Vessel wall geometries of the target artery, including normalized wall index (NWI: wall area/vessel area 100%), normalized wall thickness in …
The relationship between structure and function: why does reshaping the left ventricle surgically not always result in functional improvement?
Lunkenheimer PP, Redmann K, Cryer CW, Wübbeling F, Konertz W, Batista RJ, Ho SY, Anderson RH. Lunkenheimer PP, et al. Comput Biol Med. 2003 May;33(3):185-96. doi: 10.1016/s0010-4825(02)00085-9. Comput Biol Med. 2003. PMID: 12726797 Review.
Surgical strategies recently introduced to improve ventricular function have been based on the concepts of reduction of ventricular diameter, synchronization of myocardial activity, passive support of diastolic ventricular shape, and active support of systolic ventricular cons
Surgical strategies recently introduced to improve ventricular function have been based on the concepts of reduction of ventricular diameter …
Modelling structural determinants of ventilation heterogeneity: A perturbative approach.
Whitfield CA, Horsley A, Jensen OE. Whitfield CA, et al. PLoS One. 2018 Nov 29;13(11):e0208049. doi: 10.1371/journal.pone.0208049. eCollection 2018. PLoS One. 2018. PMID: 30496317 Free PMC article.
By applying airway constrictions inter-regionally, we have predicted the response of MBW indices to obstructions and found that they detect a narrow range of severe constrictions that reduce airway radius to 10%-30% of healthy values. ...Further, we have used …
By applying airway constrictions inter-regionally, we have predicted the response of MBW indices to obstructions and found that they …
Pupil light reflex in Parkinson's disease: evaluation with pupillometry.
Giza E, Fotiou D, Bostantjopoulou S, Katsarou Z, Karlovasitou A. Giza E, et al. Int J Neurosci. 2011 Jan;121(1):37-43. doi: 10.3109/00207454.2010.526730. Epub 2010 Nov 1. Int J Neurosci. 2011. PMID: 21034369 Clinical Trial.
We evaluated pupil light reflex (PLR) in patients with Parkinson's disease (PD) and normal controls by means of pupillometry and explored its possible relation to clinical characteristics in parkinsonian patients. PLR was evaluated using pupillometry in 66 patients with PD …
We evaluated pupil light reflex (PLR) in patients with Parkinson's disease (PD) and normal controls by means of pupillometry and explored it …
Abnormal Pulmonary Artery Bending Correlates With Increased Right Ventricular Afterload Following the Arterial Switch Operation.
Loke YH, Capuano F, Mandell J, Cross RR, Cronin I, Mass P, Balaras E, Olivieri LJ. Loke YH, et al. World J Pediatr Congenit Heart Surg. 2019 Sep;10(5):572-581. doi: 10.1177/2150135119861358. World J Pediatr Congenit Heart Surg. 2019. PMID: 31496415
METHODS: Conventional measurements and novel measurements of the pulmonary arteries were performed using CMR data from 42 ASO patients and 13 age-matched controls. Novel measurements included bending angle, normalized radius of curvature (R(c)), and normalized weighted …
METHODS: Conventional measurements and novel measurements of the pulmonary arteries were performed using CMR data from 42 ASO patients and 1 …
Evaluation of pupil mobility in patients with myasthenia gravis.
Tsiptsios D, Fotiou DF, Haidich AB, Brozou GC, Nakou M, Giantselidis C, Karlovasitou A, Fotiou F. Tsiptsios D, et al. Electromyogr Clin Neurophysiol. 2008 Jun-Jul;48(5):209-18. Electromyogr Clin Neurophysiol. 2008. PMID: 18754530 Clinical Trial.

A significant decrease in Amplitude (p < 0.001), Maximum Constriction Velocity (p < 0.001) and especially Maximum Constriction Acceleration with a perfect discrimination ability (AUC= 1, p < 0.001). was observed in the Myasthenic compared to the non-Myasthe

A significant decrease in Amplitude (p < 0.001), Maximum Constriction Velocity (p < 0.001) and especially Maximum Constricti

Carotid artery anatomy and geometry as risk factors for carotid atherosclerotic disease.
Phan TG, Beare RJ, Jolley D, Das G, Ren M, Wong K, Chong W, Sinnott MD, Hilton JE, Srikanth V. Phan TG, et al. Stroke. 2012 Jun;43(6):1596-601. doi: 10.1161/STROKEAHA.111.645499. Epub 2012 Apr 17. Stroke. 2012. PMID: 22511010 Clinical Trial.
The following were independently associated with ICA stenosis: ICA radius at the bifurcation (OR, 0.20; 95% CI, 0.14-0.29), ICA angle (OR, 1.05 per degree increment; 95% CI, 1.04-1.07), age (OR, 1.05 per year increment; 95% CI, 1.03-1.07), male sex (OR, 1.72; 95% CI, 1.08- …
The following were independently associated with ICA stenosis: ICA radius at the bifurcation (OR, 0.20; 95% CI, 0.14-0.29), ICA angle …
The use of pupillometry in the assessment of cardiac autonomic function in elite different type trained athletes.
Kaltsatou A, Kouidi E, Fotiou D, Deligiannis P. Kaltsatou A, et al. Eur J Appl Physiol. 2011 Sep;111(9):2079-87. doi: 10.1007/s00421-011-1836-0. Epub 2011 Jan 23. Eur J Appl Physiol. 2011. PMID: 21259023 Clinical Trial.
All subjects underwent three pupillometric measurements: at rest, peak exercise testing and recovery phase. The pupillometric indices studied were: baseline pupil radius (R1), minimum pupil radius (R2), maximum constriction velocity (VC(max)), maximum cons
All subjects underwent three pupillometric measurements: at rest, peak exercise testing and recovery phase. The pupillometric indices studie …
Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics.
Timmins LH, Meyer CA, Moreno MR, Moore JE. Timmins LH, et al. J Endovasc Ther. 2008 Dec;15(6):643-54. doi: 10.1583/08-2443.1. J Endovasc Ther. 2008. PMID: 19090628 Free PMC article.
METHODS: Computational modeling techniques were employed to investigate the final radius of the lumen and artery wall stresses after stent implantation. ...Atherosclerotic plaques half as stiff (0.5x), of equal stiffness (1.0x), or twice as stiff (2.0x) as the artery wall …
METHODS: Computational modeling techniques were employed to investigate the final radius of the lumen and artery wall stresses after …
20 results