Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1983 1
1988 1
1989 1
1990 1
1992 1
1996 1
2008 1
2011 3
2019 1
2020 1
2022 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

12 results

Results by year

Filters applied: . Clear all
Page 1
Stentless aortic valve replacement: an update.
Kobayashi J. Kobayashi J. Vasc Health Risk Manag. 2011;7:345-51. doi: 10.2147/VHRM.S11253. Epub 2011 Jun 2. Vasc Health Risk Manag. 2011. PMID: 21731886 Free PMC article. Review.
Freedom from reoperation at 12 years in Toronto stentless porcine valves ranged from 69% to 75%, which is much lower than for Carpentier-Edwards Perimount valves. Cusp tear with consequent aortic regurgitation was the most common cause of structural valve deteriorat …
Freedom from reoperation at 12 years in Toronto stentless porcine valves ranged from 69% to 75%, which is much lower than for Carpentier-Edw …
Early First-Generation Trifecta Valve Failure: A Case Series and a Review of the Literature.
Kaneyuki D, Nakajima H, Asakura T, Yoshitake A, Tokunaga C, Tochii M, Hayashi J, Takazawa A, Izumida H, Iguchi A. Kaneyuki D, et al. Ann Thorac Surg. 2020 Jan;109(1):86-92. doi: 10.1016/j.athoracsur.2019.05.073. Epub 2019 Jul 20. Ann Thorac Surg. 2020. PMID: 31336064 Review.
The common pathologic findings were circumferential pannus formation with noncoronary cusp tear and leaflet calcification. The rates of preoperative end-renal stage disease and postoperative prosthesis-patient mismatch were higher in patients with Trifecta valve fai …
The common pathologic findings were circumferential pannus formation with noncoronary cusp tear and leaflet calcification. The …
Impact of postoperative patient-prosthesis mismatch as a risk factor for early structural valve deterioration after aortic valve replacement with Trifecta bioprosthesis.
Wakami T, Koizumi S, Koyama T. Wakami T, et al. J Cardiothorac Surg. 2022 Jul 8;17(1):174. doi: 10.1186/s13019-022-01918-3. J Cardiothorac Surg. 2022. PMID: 35804395 Free PMC article.
Noncoronary cusp tears were observed in all patients who had undergone redo surgery. CONCLUSIONS: The most common cause of SVD was noncoronary cusp tear. Patients with PPM are at high risk of developing SVD....
Noncoronary cusp tears were observed in all patients who had undergone redo surgery. CONCLUSIONS: The most common cause of SVD was noncorona …
A lesional classification to standardize surgical management of aortic insufficiency towards valve repair.
Lansac E, Di Centa I, Raoux F, Al Attar N, Acar C, Joudinaud T, Raffoul R. Lansac E, et al. Eur J Cardiothorac Surg. 2008 May;33(5):872-8; discussion 878-80. doi: 10.1016/j.ejcts.2007.12.033. Epub 2008 Feb 6. Eur J Cardiothorac Surg. 2008. PMID: 18258445
The type II associates dilation of sino-tubular junction and annular base to a valvular lesion: IIa cusp prolapse (95 aneurysms, 200 isolated AI); IIb cusp retraction (132 rheumatic AI), IIc cusp tear (endocarditis, traumatic). CONCLUSION: A lesional classification …
The type II associates dilation of sino-tubular junction and annular base to a valvular lesion: IIa cusp prolapse (95 aneurysms, 200 isolate …
Ionescu-Shiley valve failure. I: Experience with 125 standard-profile explants.
Walley VM, Keon CA, Khalili M, Moher D, Campagna M, Keon WJ. Walley VM, et al. Ann Thorac Surg. 1992 Jul;54(1):111-6. doi: 10.1016/0003-4975(92)91153-z. Ann Thorac Surg. 1992. PMID: 1610221
Observations of these explants confirm previous suggestions about the clinical and pathologic patterns of the Ionescu-Shiley valve's failure, but are extended in this study to allow more confident statistical analyses. Cusp tear with insufficiency remains the most i …
Observations of these explants confirm previous suggestions about the clinical and pathologic patterns of the Ionescu-Shiley valve's failure …
The CryoLife-O'Brien stentless replacement aortic valve: patterns of valve failure.
Chambers JB, Parkin D, Rajani R, Shabbo F. Chambers JB, et al. J Heart Valve Dis. 2011 Jul;20(4):433-8. J Heart Valve Dis. 2011. PMID: 21863657
Six cases of structural deterioration were identified; five of these cases were due to a cusp tear (usually of the right coronary cusp), and one case was due to valve calcification. ...
Six cases of structural deterioration were identified; five of these cases were due to a cusp tear (usually of the right coron …
Long-term echocardiographic follow-up of patients with a tricuspid bioprosthesis.
Okada Y, Nasu M, Nishiuchi S, Shomura T. Okada Y, et al. ASAIO Trans. 1990 Jul-Sep;36(3):M535-7. ASAIO Trans. 1990. PMID: 2252744
Color Doppler showed regurgitation in 7 of the 20 patients who were completely followed up, but they were all asymptomatic and required no special intervention. Cusp tear or calcification requiring reoperation was not observed in this study, including 8 patients you …
Color Doppler showed regurgitation in 7 of the 20 patients who were completely followed up, but they were all asymptomatic and required no s …
The Mitroflow pericardial valve. First five years of follow-up evaluation.
Loisance D, Zouari M, Leandri J, Hillion ML, Cachera JP. Loisance D, et al. ASAIO Trans. 1989 Jul-Sep;35(3):304-7. doi: 10.1097/00002480-198907000-00041. ASAIO Trans. 1989. PMID: 2597470
At 5 years, freedom of structural deterioration is 95.2% +/- 2.1. Single cusp tear at a stent post is the most frequent lesion (86%) as calcifications are observed in three only (major in two, microscopical in one). ...
At 5 years, freedom of structural deterioration is 95.2% +/- 2.1. Single cusp tear at a stent post is the most frequent lesion …
Long-term results after aortic valve replacement with the Mitroflow pericardial valve.
Reber D, Birnbaum DE, Tollenaere P, Eschenbruch E. Reber D, et al. J Cardiovasc Surg (Torino). 1996 Dec;37(6 Suppl 1):23-7. J Cardiovasc Surg (Torino). 1996. PMID: 10064343
Postoperative valve-related morbidity included prosthetic endocarditis (1 patient) one year postoperatively; degenerative prosthetic failure (1 patient) 27 months postop; cusp tear (1 patient) with minimal hemodynamic changes after four years. ...
Postoperative valve-related morbidity included prosthetic endocarditis (1 patient) one year postoperatively; degenerative prosthetic failure …
Failure of Hancock xenograft valve: importance of valve position (4- to 9-year follow-up).
Bolooki H, Mallon S, Kaiser GA, Thurer RJ, Kieval J. Bolooki H, et al. Ann Thorac Surg. 1983 Sep;36(3):246-52. doi: 10.1016/s0003-4975(10)60124-5. Ann Thorac Surg. 1983. PMID: 6615061
These valves showed extensive calcification, leaflet perforation, or cusp tear. Structural failure was unrelated to valve size, year of implantation, or valve shelf-life. ...
These valves showed extensive calcification, leaflet perforation, or cusp tear. Structural failure was unrelated to valve size …
12 results