Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1992 1
2002 1
2007 1
2008 1
2012 1
2017 1
2018 2
2019 1
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

9 results

Results by year

Filters applied: . Clear all
Page 1
Isolated double-orifice mitral valve in octogenarian.
Graham FJ, Jenkins SMM. Graham FJ, et al. Eur Heart J Cardiovasc Imaging. 2018 Aug 1;19(8):957. doi: 10.1093/ehjci/jey066. Eur Heart J Cardiovasc Imaging. 2018. PMID: 29688294 No abstract available.
Percutaneous and off-pump treatments for functional mitral regurgitation.
Fukamachi K. Fukamachi K. J Artif Organs. 2008;11(1):12-8. doi: 10.1007/s10047-007-0399-7. Epub 2008 Apr 15. J Artif Organs. 2008. PMID: 18414987 Review.
Several devices, such as the PTMA, CARILLON, Monarch, and PS3 systems, are in clinical trials. Percutaneous edge-to-edge repair devices mimic the surgical Alfieri edge-to-edge repair technique, creating a double-orifice mitral valve; of these, M …
Several devices, such as the PTMA, CARILLON, Monarch, and PS3 systems, are in clinical trials. Percutaneous edge-to-edge repair devic …
Mitral valve reserve in double-orifice technique: an exercise echocardiographic study.
Agricola E, Maisano F, Oppizzi M, De Bonis M, Torracca L, La Canna G, Alfieri O. Agricola E, et al. J Heart Valve Dis. 2002 Sep;11(5):637-43. J Heart Valve Dis. 2002. PMID: 12358399 Clinical Trial.
An exercise echocardiographic study was carried out to investigate valve function and hemodynamics in patients who had undergone double-orifice mitral valve repair. METHODS: Thirty patients (mean age 49.1 +/- 12.7 years) with previous double- …
An exercise echocardiographic study was carried out to investigate valve function and hemodynamics in patients who had undergone double
A novel user-friendly transcatheter edge-to-edge mitral valve repair device in a porcine model.
Pan W, Pan C, Jilaihawi H, Wei L, Tang Y, Zhou D, Ge J. Pan W, et al. Catheter Cardiovasc Interv. 2019 Jun 1;93(7):1354-1360. doi: 10.1002/ccd.27976. Epub 2018 Nov 15. Catheter Cardiovasc Interv. 2019. PMID: 30443976
The gross observation showed that the clamp device was securely attached and created a double-orifice mitral valve in all pigs except the failed one. In the eight pigs living to the endpoint, the clamp device was noted to be completely endothelialized. …
The gross observation showed that the clamp device was securely attached and created a double-orifice mitral valve
Very long-term results (up to 17 years) with the double-orifice mitral valve repair combined with ring annuloplasty for degenerative mitral regurgitation.
De Bonis M, Lapenna E, Lorusso R, Buzzatti N, Gelsomino S, Taramasso M, Vizzardi E, Alfieri O. De Bonis M, et al. J Thorac Cardiovasc Surg. 2012 Nov;144(5):1019-24. doi: 10.1016/j.jtcvs.2012.07.034. Epub 2012 Aug 25. J Thorac Cardiovasc Surg. 2012. PMID: 22929220 Free article.
OBJECTIVE: The very long-term results of the double-orifice mitral valve repair are unknown. The aim of this study was to assess the late clinical and echocardiographic outcomes of this technique in patients with degenerative mitral regurgitatio …
OBJECTIVE: The very long-term results of the double-orifice mitral valve repair are unknown. The aim of this stu …
Novel arm-width-expandable transcatheter edge-to-edge repair system: Preclinical experiment and first-in-human study.
Long Y, Li W, Chen S, Li M, Hou S, Pan C, Zhou D, Pan W, Ge J. Long Y, et al. Catheter Cardiovasc Interv. 2023 Aug;102(2):301-309. doi: 10.1002/ccd.30758. Epub 2023 Jul 20. Catheter Cardiovasc Interv. 2023. PMID: 37471710
RESULTS: The device success rate was 100% (14/14) in the animal experiments, and all clips were deployed at the A2P2 segments, forming a double-orifice mitral valve. Gross observations on day 180 showed a wide and continuous tissue bridge between the l …
RESULTS: The device success rate was 100% (14/14) in the animal experiments, and all clips were deployed at the A2P2 segments, forming a …
A successful cesarean delivery without fetal or maternal morbidity in an Eisenmenger patient with cor triatriatum sinistrum, double-orifice mitral valve, large ventricular septal defect, and single ventricle who was under long-term bosentan treatment.
Tokgöz HC, Kaymaz C, Poci N, Akbal ÖY, Öztürk S. Tokgöz HC, et al. Turk Kardiyol Dern Ars. 2017 Mar;45(2):184-188. doi: 10.5543/tkda.2016.17747. Turk Kardiyol Dern Ars. 2017. PMID: 28424444 Free article.
Presently described is successful cesarean delivery in a pregnancy superimposed on long-term bosentan treatment in an Eisenmenger syndrome patient with cor triatriatum sinistrum, double-orifice mitral valve, and large ventricular septal defect resultin …
Presently described is successful cesarean delivery in a pregnancy superimposed on long-term bosentan treatment in an Eisenmenger syndrome p …
Echocardiographic guidance and assessment of percutaneous repair for mitral regurgitation with the Evalve MitraClip: lessons learned from EVEREST I.
Silvestry FE, Rodriguez LL, Herrmann HC, Rohatgi S, Weiss SJ, Stewart WJ, Homma S, Goyal N, Pulerwitz T, Zunamon A, Hamilton A, Merlino J, Martin R, Krabill K, Block PC, Whitlow P, Tuzcu EM, Kapadia S, Gray WA, Reisman M, Wasserman H, Schwartz A, Foster E, Feldman T, Wiegers SE. Silvestry FE, et al. J Am Soc Echocardiogr. 2007 Oct;20(10):1131-40. doi: 10.1016/j.echo.2007.02.003. Epub 2007 Jun 13. J Am Soc Echocardiogr. 2007. PMID: 17570634 Clinical Trial.
METHODS: In EVEREST I, the US multicenter phase I safety and feasibility trial, 47 patients with 3 or 4+ mitral regurgitation (MR) were enrolled. ...RESULTS: TEE guidance facilitated the creation of a double-orifice mitral valve in all 47 patien …
METHODS: In EVEREST I, the US multicenter phase I safety and feasibility trial, 47 patients with 3 or 4+ mitral regurgitation (MR) we …
Unusual sequelae after percutaneous mitral valvuloplasty: a Doppler echocardiographic study.
O'Shea JP, Abascal VM, Wilkins GT, Marshall JE, Brandi S, Acquatella H, Block PC, Palacios IF, Weyman AE. O'Shea JP, et al. J Am Coll Cardiol. 1992 Jan;19(1):186-91. doi: 10.1016/0735-1097(92)90071-t. J Am Coll Cardiol. 1992. PMID: 1729331 Free article.
These included rupture of a posterior mitral valve leaflet, producing a flail distal leaflet portion with severe mitral regurgitation detected on Doppler color flow mapping (n = 1); asymptomatic rupture of the chordae tendineae attached to the anterior mitral valve leaflet with s …
These included rupture of a posterior mitral valve leaflet, producing a flail distal leaflet portion with severe mitral regurgitation detect …