Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1993 1
1997 1
2004 1
2005 1
2010 1
2011 1
2012 2
2014 1
2015 4
2016 3
2017 1
2018 2
2019 1
2020 1
2022 1
2023 3
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

21 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Extracorporeal Circuit Clot"
Page 1
Early Blood Clot Detection Using Forward Scattering Light Measurements Is Not Superior to Delta Pressure Measurements.
Fischbach A, Lamberti M, Simons JA, Wrede E, Theißen A, Winnersbach P, Rossaint R, Stollenwerk A, Bleilevens C. Fischbach A, et al. Biosensors (Basel). 2023 Dec 4;13(12):1012. doi: 10.3390/bios13121012. Biosensors (Basel). 2023. PMID: 38131772 Free PMC article.
A miniaturized in vitro test circuit, including a custom-made test chamber, was used. Heparinized human whole blood was circulated through the test circuit until clot formation occurred. ...Despite several modifications in the LED positions on the test chambe …
A miniaturized in vitro test circuit, including a custom-made test chamber, was used. Heparinized human whole blood was circulated th …
Soluble fibrin is a useful marker for predicting extracorporeal membrane oxygenation circuit exchange because of circuit clots.
Hoshino K, Muranishi K, Kawano Y, Hatomoto H, Yamasaki S, Nakamura Y, Ishikura H. Hoshino K, et al. J Artif Organs. 2018 Jun;21(2):196-200. doi: 10.1007/s10047-018-1021-x. Epub 2018 Jan 30. J Artif Organs. 2018. PMID: 29383543
A circuit clot is one of the most frequent complications during extracorporeal membrane oxygenation (ECMO) support. ...ECMO support lasted 106 days. The 6 days on which the ECMO circuits were exchanged were considered as circuit clot (+) …
A circuit clot is one of the most frequent complications during extracorporeal membrane oxygenation (ECMO) support. ... …
Assessment of hemostatic changes after initiation of continuous venovenous hemodialysis.
Wand S, Schneider S, Meybohm P, Zacharowski K, Weber CF. Wand S, et al. Clin Lab. 2015;61(3-4):379-87. doi: 10.7754/clin.lab.2014.140931. Clin Lab. 2015. PMID: 25975006
No predictors for premature clotting of the circuit were identified. CONCLUSIONS: The results of the present study indicate that CRRT may lead to impaired primary hemostasis as shown by a decrease in ex vivo arachidonic acid-induced platelet aggregation. Moreover, viscoela …
No predictors for premature clotting of the circuit were identified. CONCLUSIONS: The results of the present study indicate that CRRT …
Detection of Thrombosis in the Extracorporeal Membrane Oxygenation Circuit by Infrasound: Proof of Concept.
Fuchs G, Berg N, Eriksson A, Prahl Wittberg L. Fuchs G, et al. Artif Organs. 2017 Jun;41(6):573-579. doi: 10.1111/aor.12782. Epub 2016 Sep 22. Artif Organs. 2017. PMID: 27654663 Free PMC article.
As of today, there exist no reliable, objective methods for early detection of thrombi in the extracorporeal membrane oxygenators (ECMO) system. Within the ECMO system, thrombi are not always fixed to a certain component or location in the circuit. Thus, clot
As of today, there exist no reliable, objective methods for early detection of thrombi in the extracorporeal membrane oxygenators (EC …
Detecting Oxygenator Thrombosis in ECMO: A Review of Current Techniques and an Exploration of Future Directions.
Leerson J, Tulloh A, Lopez FT, Gregory S, Buscher H, Rosengarten G. Leerson J, et al. Semin Thromb Hemost. 2024 Mar;50(2):253-270. doi: 10.1055/s-0043-1772843. Epub 2023 Aug 28. Semin Thromb Hemost. 2024. PMID: 37640048 Review.
Blood clot formation in the circuit is one of the most common complications in ECMO, having potentially harmful and even fatal consequences. ...We investigate the feasibility of solutions proposed in the surrounding literature and explore two areas that hold promise …
Blood clot formation in the circuit is one of the most common complications in ECMO, having potentially harmful and even fatal …
Alterations in Pre/Post Oxygenator Flows Due to Fibrin Deposition in the CardioHelp System-A Case Report.
Wahl T, Stokes A, Varner C, Zeybek B, Bardia A. Wahl T, et al. J Extra Corpor Technol. 2022 Sep;54(3):239-241. doi: 10.1182/ject-239-241. J Extra Corpor Technol. 2022. PMID: 36742210 Free PMC article.
On Day 8 of ECMO support, it was noticed that flows steadily decreased despite unchanged RPMs. Unlike typical blood flow to circuit pressure relationships, the circuit pressures did not correlate with the observed decreased flow. ...Due to reduced flow, the deltaP w …
On Day 8 of ECMO support, it was noticed that flows steadily decreased despite unchanged RPMs. Unlike typical blood flow to circuit p …
Low molecular weight heparin and haemodialysis: neutralization by protaminchloride.
Andrassy K. Andrassy K. Blood Coagul Fibrinolysis. 1993 Dec;4 Suppl 1:S39-43. Blood Coagul Fibrinolysis. 1993. PMID: 8180328 Review.
Unfractionated heparin (UFH) is the most widely used agent in preventing clot formation in the extracorporeal circuit. The dose of heparin varies and is dependent on biocompatibility of membranes, the construction of the dialyser and the roller pump segment b …
Unfractionated heparin (UFH) is the most widely used agent in preventing clot formation in the extracorporeal circuit. …
The Effect of Citrate on Clot Formation, Dialyzer Reuse, and Anemia in Hemodialysis Patients.
Trakarnvanich T, Thirathanakul S, Sriphueng N, Thumrongthongjaroon P, Kurathong S, Ngamvichchukorn T, Trakarnvanich T. Trakarnvanich T, et al. Blood Purif. 2019;47(4):361-368. doi: 10.1159/000495025. Epub 2018 Dec 13. Blood Purif. 2019. PMID: 30544124
BACKGROUND: Citrate anticoagulation is increasingly favored for preventing extracorporeal circuit clotting during renal replacement therapy. This study tested the effect of citrate compared with acetate on heparin avoidance and other parameters. ...
BACKGROUND: Citrate anticoagulation is increasingly favored for preventing extracorporeal circuit clotting during renal replac …
What are the adverse effects associated with the combined use of intravenous lipid emulsion and extracorporeal membrane oxygenation in the poisoned patient?
Lee HM, Archer JR, Dargan PI, Wood DM. Lee HM, et al. Clin Toxicol (Phila). 2015 Mar;53(3):145-50. doi: 10.3109/15563650.2015.1004582. Epub 2015 Jan 29. Clin Toxicol (Phila). 2015. PMID: 25634667 Review.
An in vitro study involving the continuous infusion of 20% ILE at 3 mL/h for 24 h demonstrated layering (separation of intact fat emulsion from blood) and agglutination (clumping resulting in little or no flow of fat emulsion through the circuit) in all circuits wit …
An in vitro study involving the continuous infusion of 20% ILE at 3 mL/h for 24 h demonstrated layering (separation of intact fat emulsion f …
Monitoring of viral load by RT-PCR caused decision making to continue ECMO therapy for a patient with COVID-19.
Sakamaki I, Morinaga Y, Tani H, Takegoshi Y, Fukui Y, Kawasuji H, Ueno A, Miyajima Y, Wakasugi M, Kawagishi T, Kuwano H, Hatano T, Shibuya T, Okudera H, Yamamoto Y. Sakamaki I, et al. J Infect Chemother. 2020 Dec;26(12):1324-1327. doi: 10.1016/j.jiac.2020.08.014. Epub 2020 Aug 20. J Infect Chemother. 2020. PMID: 32900659 Free PMC article.
Two days after the introduction of ECMO, C-reactive protein (CRP) increased, chest X-p showed no improvement in pneumonia, and PaO2/FiO2 decreased again. As D-dimer rose and found a blood clot in the ECMO circuit, we had to decide whether to replace the circuit
Two days after the introduction of ECMO, C-reactive protein (CRP) increased, chest X-p showed no improvement in pneumonia, and PaO2/FiO2 dec …
21 results