Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2006 1
2007 1
2010 2
2013 1
2015 5
2016 2
2017 2
2018 2
2019 7
2020 8
2021 4
2022 2
2023 3
2024 2

Text availability

Article attribute

Article type

Publication date

Search Results

32 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Infective Phlebitis"
Page 1
The Practice and Complications of Midline Catheters: A Systematic Review.
Tripathi S, Kumar S, Kaushik S. Tripathi S, et al. Crit Care Med. 2021 Feb 1;49(2):e140-e150. doi: 10.1097/CCM.0000000000004764. Crit Care Med. 2021. PMID: 33372744
The average dwell time was 16.3 days (n = 4,412). The adjusted mean infection rate was 0.28/1,000 catheter days, with 64% of studies not reporting any infection with midline catheter. ...Active surveillance of infections due to midline catheters is recommende …
The average dwell time was 16.3 days (n = 4,412). The adjusted mean infection rate was 0.28/1,000 catheter days, with 64% of studies …
Peripheral intravenous catheter infection and failure: A systematic review and meta-analysis.
Marsh N, Larsen EN, Ullman AJ, Mihala G, Cooke M, Chopra V, Ray-Barruel G, Rickard CM. Marsh N, et al. Int J Nurs Stud. 2024 Mar;151:104673. doi: 10.1016/j.ijnurstu.2023.104673. Epub 2023 Dec 9. Int J Nurs Stud. 2024. PMID: 38142634 Free article. Review.
We performed a systematic review to determine the prevalence of peripheral intravenous catheter infection and all-cause failure. METHODS: The Cochrane Library, PubMed, CINAHL, and EMBASE were searched for observational studies and randomised controlled trials that reported …
We performed a systematic review to determine the prevalence of peripheral intravenous catheter infection and all-cause failure. METH …
Clinically-indicated replacement versus routine replacement of peripheral venous catheters.
Webster J, Osborne S, Rickard CM, Marsh N. Webster J, et al. Cochrane Database Syst Rev. 2019 Jan 23;1(1):CD007798. doi: 10.1002/14651858.CD007798.pub5. Cochrane Database Syst Rev. 2019. PMID: 30671926 Free PMC article.
BACKGROUND: US Centers for Disease Control guidelines recommend replacement of peripheral intravenous catheters (PIVC) no more frequently than every 72 to 96 hours. Routine replacement is thought to reduce the risk of phlebitis and bloodstream infection. Catheter in …
BACKGROUND: US Centers for Disease Control guidelines recommend replacement of peripheral intravenous catheters (PIVC) no more frequently th …
Effectiveness of insertion and maintenance bundles in preventing peripheral intravenous catheter-related complications and bloodstream infection in hospital patients: A systematic review.
Ray-Barruel G, Xu H, Marsh N, Cooke M, Rickard CM. Ray-Barruel G, et al. Infect Dis Health. 2019 Aug;24(3):152-168. doi: 10.1016/j.idh.2019.03.001. Epub 2019 Apr 18. Infect Dis Health. 2019. PMID: 31005606 Free article.
Search terms: peripheral intravenous catheter/cannula, insertion, maintenance, bundle, infection, infiltration, extravasation, dislodgement, thrombosis, occlusion, and phlebitis. ...Despite testing different bundles, 12 studies reported reductions in phlebitis
Search terms: peripheral intravenous catheter/cannula, insertion, maintenance, bundle, infection, infiltration, extravasation, dislod …
A comparison of silicone and polyurethane PICC lines and postinsertion complication rates: a systematic review.
Seckold T, Walker S, Dwyer T. Seckold T, et al. J Vasc Access. 2015 May-Jun;16(3):167-77. doi: 10.5301/jva.5000330. Epub 2015 Jan 23. J Vasc Access. 2015. PMID: 25634150 Review.
Joanna Briggs Institute tools were used to extract data from the final 19 articles with information collated relating to catheter type, patient type, overall complication rate, rates of infection, occlusion, dislodgment, phlebitis, thrombus and rupture. ...Oncology …
Joanna Briggs Institute tools were used to extract data from the final 19 articles with information collated relating to catheter type, pati …
Relationship between indwelling site and peripheral venous catheter-related complications in adult hospitalized patients: A systematic review and meta-analysis.
Fan XW, Xu L, Wei WS, Chen YM, Yang YQ. Fan XW, et al. J Clin Nurs. 2023 Apr;32(7-8):1014-1024. doi: 10.1111/jocn.16241. Epub 2022 Feb 28. J Clin Nurs. 2023. PMID: 35229381 Review.
However, the differences between the PVC indwelling sites were not significant (total complications: P = 0.43; phlebitis: P = 0.35; infiltration/extravasation: P = 0.51). Both incidence of total complications and infiltration/extravasation analyses showed high heterogeneit …
However, the differences between the PVC indwelling sites were not significant (total complications: P = 0.43; phlebitis: P = 0.35; i …
Effectiveness, safety and comfort of StatLock securement for peripherally-inserted central catheters: A systematic review and meta-analysis.
Luo X, Guo Y, Yu H, Li S, Yin X. Luo X, et al. Nurs Health Sci. 2017 Dec;19(4):403-413. doi: 10.1111/nhs.12361. Epub 2017 Jul 21. Nurs Health Sci. 2017. PMID: 28730735 Review.
Moreover, patients in the StatLock group had lower incidence of skin ulceration, phlebitis, catheter-related bloodstream infection, and cellulitis, and felt more comfortable compared with those in the control group. ...
Moreover, patients in the StatLock group had lower incidence of skin ulceration, phlebitis, catheter-related bloodstream infection
Treatment for superficial infusion thrombophlebitis of the upper extremity.
Di Nisio M, Peinemann F, Porreca E, Rutjes AW. Di Nisio M, et al. Cochrane Database Syst Rev. 2015 Nov 20;2015(11):CD011015. doi: 10.1002/14651858.CD011015.pub2. Cochrane Database Syst Rev. 2015. PMID: 26588711 Free PMC article. Review.
Only one study of 15 participants assessed thrombus extension and symptomatic venous thromboembolism with either oral non-steroidal anti-inflammatory drugs or low-molecular-weight heparin, and it reported no cases of either. No study reported on the development of suppurative …
Only one study of 15 participants assessed thrombus extension and symptomatic venous thromboembolism with either oral non-steroidal anti-inf …
Devices and dressings to secure peripheral venous catheters: A Cochrane systematic review and meta-analysis.
Marsh N, Webster J, Mihala G, Rickard CM. Marsh N, et al. Int J Nurs Stud. 2017 Feb;67:12-19. doi: 10.1016/j.ijnurstu.2016.11.007. Epub 2016 Nov 16. Int J Nurs Stud. 2017. PMID: 27889585 Review.
However, the relative effects of transparent dressings and gauze on phlebitis (RR 0.89; 95% CI 0.47-1.68) and infiltration (RR 0.80; 95% CI 0.48-1.33) are unclear. A single study identified less frequent dislodgement or accidental catheter removal with bordered transparent …
However, the relative effects of transparent dressings and gauze on phlebitis (RR 0.89; 95% CI 0.47-1.68) and infiltration (RR 0.80; …
Clinically-indicated replacement versus routine replacement of peripheral venous catheters.
Webster J, Osborne S, Rickard CM, New K. Webster J, et al. Cochrane Database Syst Rev. 2015 Aug 14;(8):CD007798. doi: 10.1002/14651858.CD007798.pub4. Cochrane Database Syst Rev. 2015. Update in: Cochrane Database Syst Rev. 2019 Jan 23;1:CD007798. doi: 10.1002/14651858.CD007798.pub5. PMID: 26272489 Updated. Review.
BACKGROUND: US Centers for Disease Control guidelines recommend replacement of peripheral intravenous (IV) catheters no more frequently than every 72 to 96 hours. Routine replacement is thought to reduce the risk of phlebitis and bloodstream infection. Catheter inse …
BACKGROUND: US Centers for Disease Control guidelines recommend replacement of peripheral intravenous (IV) catheters no more frequently than …
32 results