Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1996 1
1997 1
2001 2
2003 1
2004 2
2005 1
2006 1
2007 1
2010 1
2011 1
2016 1
2018 2
2019 2
2020 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

16 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Intra-Atrial Conduction Delay by ECG Finding"
Page 1
Inter/Intra-Atrial Dissociation in Patients With Maze Procedure and Its Clinical Implications: Pseudo-Block and Pseudo-Ventricular Tachycardia.
Do U, Nam GB, Kim M, Cho MS, Kim J, Choi KJ, Kim YH. Do U, et al. J Am Heart Assoc. 2020 Dec;9(23):e018241. doi: 10.1161/JAHA.120.018241. Epub 2020 Nov 20. J Am Heart Assoc. 2020. PMID: 33215559 Free PMC article.
Background Severe conduction delay and inter/intra-atrial dissociation may occur in patients who undergo an extensive catheter ablation or a maze procedure for atrial tachyarrhythmia. We report a series of patients with inter/intra-atrial
Background Severe conduction delay and inter/intra-atrial dissociation may occur in patients who undergo an exte …
Electrophysiological Effects of Selective Atrial Coronary Artery Occlusion in Humans.
Álvarez-García J, Vives-Borrás M, Gomis P, Ordoñez-Llanos J, Ferrero-Gregori A, Serra-Peñaranda A, Cinca J. Álvarez-García J, et al. Circulation. 2016 Jun 7;133(23):2235-42. doi: 10.1161/CIRCULATIONAHA.116.021700. Epub 2016 May 5. Circulation. 2016. PMID: 27151531 Free article.
In comparison with the non-ABO, patients with ABO showed: (1) higher incidence of periprocedural myocardial infarction (20% versus 53%, P=0.01); (2) more frequent intra-atrial conduction delay (19% versus 46%, P=0.03); (3) more marked PR segment deviat …
In comparison with the non-ABO, patients with ABO showed: (1) higher incidence of periprocedural myocardial infarction (20% versus 53%, P=0. …
Doppler tissue evaluation of intra-atrial and interatrial electromechanical delay and comparison with P-wave dispersion in patients with mitral stenosis.
Ozer N, Yavuz B, Can I, Atalar E, Aksöyek S, Ovünç K, Ozmen F, Kes S. Ozer N, et al. J Am Soc Echocardiogr. 2005 Sep;18(9):945-8. doi: 10.1016/j.echo.2005.01.015. J Am Soc Echocardiogr. 2005. PMID: 16153519 Clinical Trial.
OBJECTIVE: The aim of our study was to: (1) measure atrial electromechanical delay in patients with mitral stenosis (MS) and in a control group; (2) find the echocardiographic parameters that affect atrial electromechanical delay; and (3) examine the correlation bet …
OBJECTIVE: The aim of our study was to: (1) measure atrial electromechanical delay in patients with mitral stenosis (MS) and in a con …
The Duration of the Amplified Sinus-P-Wave Identifies Presence of Left Atrial Low Voltage Substrate and Predicts Outcome After Pulmonary Vein Isolation in Patients With Persistent Atrial Fibrillation.
Jadidi A, Müller-Edenborn B, Chen J, Keyl C, Weber R, Allgeier J, Moreno-Weidmann Z, Trenk D, Neumann FJ, Lehrmann H, Arentz T. Jadidi A, et al. JACC Clin Electrophysiol. 2018 Apr;4(4):531-543. doi: 10.1016/j.jacep.2017.12.001. Epub 2018 Feb 3. JACC Clin Electrophysiol. 2018. PMID: 30067494 Free article.
OBJECTIVES: Left atrial (LA) low-voltage substrate (LVS) potentially slows intra-atrial conduction, which might identify patients at risk for arrhythmia recurrence following pulmonary vein isolation (PVI). ...CONCLUSIONS: Advanced arrhythmogenic LVS is associ …
OBJECTIVES: Left atrial (LA) low-voltage substrate (LVS) potentially slows intra-atrial conduction, which might identif …
Long term evaluation of electromechanical delay in patients with atrial septal defect after transcatheter closure.
Öz A, Aruğaslan E, Çınar T, Keskin M, Hayıroğlu MI, Avşar Ş, Karataş MB, Aydın BA, Demir K, Güngör B, Bolca O. Öz A, et al. Int J Cardiovasc Imaging. 2019 Jan;35(1):33-39. doi: 10.1007/s10554-018-1426-x. Epub 2018 Jul 30. Int J Cardiovasc Imaging. 2019. PMID: 30062536
Some studies have been showed that electromechanical delay, which may pose an increased tendency to atrial fibrillation, may prolong in patients with various clinical conditions. ...Therefore, in the present study, we prospectively evaluated the mid-term and long-te …
Some studies have been showed that electromechanical delay, which may pose an increased tendency to atrial fibrillation, may prolong …
Effects of chronic omega-3 polyunsaturated fatty acid supplementation on human atrial electrophysiology.
Kumar S, Sutherland F, Rosso R, Teh AW, Lee G, Heck PM, Feldman A, Medi C, Watt S, Garg ML, Sparks PB. Kumar S, et al. Heart Rhythm. 2011 Apr;8(4):562-8. doi: 10.1016/j.hrthm.2010.12.017. Epub 2010 Dec 13. Heart Rhythm. 2011. PMID: 21147262 Clinical Trial.
The following were compared at time of EP study: serum omega-3 levels; right atrial and coronary sinus effective refractory periods (ERPs); interatrial, intra-atrial, left atrial, and coronary sinus conduction at baseline and the maximal conduction
The following were compared at time of EP study: serum omega-3 levels; right atrial and coronary sinus effective refractory periods (ERPs); …
Predicting post-coronary bypass surgery atrial arrhythmias from the preoperative electrocardiogram.
Passman R, Beshai J, Pavri B, Kimmel S. Passman R, et al. Am Heart J. 2001 Nov;142(5):806-10. doi: 10.1067/mhj.2001.118736. Am Heart J. 2001. PMID: 11685166
The purpose of this study was to develop a prediction rule for post-CABG AF on the basis of patient age and the preoperative electrocardiogram (ECG). METHODS: The charts of 152 consecutive patients undergoing isolated CABG at one institution were reviewed and the preoperat …
The purpose of this study was to develop a prediction rule for post-CABG AF on the basis of patient age and the preoperative electrocardiogr …
Effects of MgSO4 and glucose, insulin and potassium (GIK) on atrial conduction during the first 12 hours after DC-conversion of chronic atrial fibrillation.
Ingemansson MP, Carlson J, Platonov P, Olsson SB. Ingemansson MP, et al. Scand Cardiovasc J. 2001 Oct;35(5):340-6. doi: 10.1080/140174301317116325. Scand Cardiovasc J. 2001. PMID: 11771826 Clinical Trial.
CONCLUSION: Bolus infusion of MgSO4 2 h after DC-conversion of CAF produced an intra-atrial conduction delay that could be reversed by adding a GIK infusion, in spite of a concomitant increase in serum Mg concentration. No recovery of the intra- …
CONCLUSION: Bolus infusion of MgSO4 2 h after DC-conversion of CAF produced an intra-atrial conduction delay tha …
A novel method of multisite atrial pacing, incorporating Bachmann's bundle area and coronary sinus ostium, for electrical atrial resynchronization in patients with recurrent atrial fibrillation.
Lewicka-Nowak E, Kutarski A, Dabrowska-Kugacka A, Rucinski P, Zagozdzon P, Raczak G. Lewicka-Nowak E, et al. Europace. 2007 Sep;9(9):805-11. doi: 10.1093/europace/eum152. Epub 2007 Aug 1. Europace. 2007. PMID: 17670780
AIMS: The aim of the study was to assess efficacy and safety of a novel method of multisite atrial pacing, incorporating Bachmann's bundle (BB) and coronary sinus (CS) ostium pacing, which was implemented for the first time in atrial fibrillation (AF) patients with intra- …
AIMS: The aim of the study was to assess efficacy and safety of a novel method of multisite atrial pacing, incorporating Bachmann's bundle ( …
Extremely short setting of optimal sensed atrioventricular interval in patients after Fontan procedure with implanted dual-chamber pacemaker.
Miyazaki A, Yoshimura SI, Matsutani H, Miyake M, Negishi J, Yamanaka K, Yamada O, Doi H, Ohuchi H. Miyazaki A, et al. Cardiol Young. 2019 Nov;29(11):1375-1379. doi: 10.1017/S1047951119002257. Epub 2019 Sep 11. Cardiol Young. 2019. PMID: 31507257
The time differences between sensed atrioventricular interval and actual P wave and ventricular pacing interval occurred because of the site of the epicardial atrial pacing leads and the intra-atrial conduction delay. CONCLUSION: We need to consider th …
The time differences between sensed atrioventricular interval and actual P wave and ventricular pacing interval occurred because of the site …
16 results