Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1946 4
1947 10
1948 2
1949 7
1950 8
1951 13
1952 9
1953 11
1954 9
1955 13
1956 11
1957 17
1958 19
1959 20
1960 15
1961 21
1962 15
1963 23
1964 24
1965 22
1966 40
1967 54
1968 50
1969 61
1970 77
1971 95
1972 119
1973 126
1974 159
1975 1457
1976 1706
1977 1498
1978 1573
1979 1860
1980 2091
1981 2231
1982 2550
1983 3164
1984 3658
1985 3963
1986 4226
1987 4592
1988 4930
1989 5933
1990 6497
1991 7062
1992 7653
1993 8422
1994 9074
1995 10002
1996 10994
1997 11998
1998 12689
1999 13443
2000 14480
2001 15224
2002 16074
2003 17728
2004 19124
2005 21777
2006 23820
2007 26312
2008 28142
2009 30570
2010 33724
2011 37869
2012 41359
2013 44782
2014 47153
2015 49343
2016 50488
2017 51873
2018 53945
2019 56880
2020 64515
2021 71140
2022 69879
2023 62783
2024 27083

Text availability

Article attribute

Article type

Publication date

Search Results

976,566 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Lesion with Diameter of 4 mm or More"
Page 1
Quantification of coronary artery calcium using ultrafast computed tomography.
Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M Jr, Detrano R. Agatston AS, et al. J Am Coll Cardiol. 1990 Mar 15;15(4):827-32. doi: 10.1016/0735-1097(90)90282-t. J Am Coll Cardiol. 1990. PMID: 2407762 Free article.
Sensitivity, specificity and predictive values for clinical coronary artery disease were calculated for several total calcium scores in each decade. ...The negative predictive value of a 0 score was 98%, 94% and 100% for age groups 40 to 49, 50 to 59 a …
Sensitivity, specificity and predictive values for clinical coronary artery disease were calculated for several total calcium scor
Focused Cardiac Ultrasonography.
Spencer KT, Flachskampf FA. Spencer KT, et al. JACC Cardiovasc Imaging. 2019 Jul;12(7 Pt 1):1243-1253. doi: 10.1016/j.jcmg.2018.12.036. JACC Cardiovasc Imaging. 2019. PMID: 31272607 Free article. Review.
Implementation of the mouse frailty index.
Kane AE, Ayaz O, Ghimire A, Feridooni HA, Howlett SE. Kane AE, et al. Can J Physiol Pharmacol. 2017 Oct;95(10):1149-1155. doi: 10.1139/cjpp-2017-0025. Epub 2017 May 2. Can J Physiol Pharmacol. 2017. PMID: 28463656 Review.
This review summarises the current literature, presents some original data, and suggests areas for future research on the current applications of the mouse FI, inter-rater reliability of the FI, the effect of observer characteristics and environmental factors on mouse FI …
This review summarises the current literature, presents some original data, and suggests areas for future research on the current applicatio …
Joint counts in inflammatory arthritis.
Scott IC, Scott DL. Scott IC, et al. Clin Exp Rheumatol. 2014 Sep-Oct;32(5 Suppl 85):S-7-12. Epub 2014 Oct 30. Clin Exp Rheumatol. 2014. PMID: 25365082 Review.
RESULTS: The current widely used joint count assesses 28 peripheral joints. In RA these are usually incorporated in a composite score of disease activity, termed the disease activity score on a 28-joint count (DAS28). Assessing 28 joints has a strong 'floor-effect' …
RESULTS: The current widely used joint count assesses 28 peripheral joints. In RA these are usually incorporated in a composite score
Systematic Review and Meta-analysis of Diagnostic Accuracy of Percutaneous Renal Tumour Biopsy.
Marconi L, Dabestani S, Lam TB, Hofmann F, Stewart F, Norrie J, Bex A, Bensalah K, Canfield SE, Hora M, Kuczyk MA, Merseburger AS, Mulders PFA, Powles T, Staehler M, Ljungberg B, Volpe A. Marconi L, et al. Eur Urol. 2016 Apr;69(4):660-673. doi: 10.1016/j.eururo.2015.07.072. Epub 2015 Aug 29. Eur Urol. 2016. PMID: 26323946 Review.
A good (kappa = 0.683) and a fair (kappa = 0.34) agreement were observed between histologic subtype and Fuhrman grade on RTB and surgical specimen, respectively. ...
A good (kappa = 0.683) and a fair (kappa = 0.34) agreement were observed between histologic subtype and Fuhrman grade on RTB and surg …
Systematic review of the agreement of tonometers with Goldmann applanation tonometry.
Cook JA, Botello AP, Elders A, Fathi Ali A, Azuara-Blanco A, Fraser C, McCormack K, Margaret Burr J; Surveillance of Ocular Hypertension Study Group. Cook JA, et al. Ophthalmology. 2012 Aug;119(8):1552-7. doi: 10.1016/j.ophtha.2012.02.030. Epub 2012 May 10. Ophthalmology. 2012. PMID: 22578443 Review.
The agreement (95% limits) seemed to vary across tonometers: 0.2 mmHg (-3.8 to 4.3 mmHg) for the NCT to 2.7 mmHg (-4.1 to 9.6 mmHg) for the Ocuton S. The estimated proportion within 2 mmHg of the GAT ranged from 33% (Ocuton S) to 66% and 59% (NCT and HAT, respective …
The agreement (95% limits) seemed to vary across tonometers: 0.2 mmHg (-3.8 to 4.3 mmHg) for the NCT to 2.7 mmHg (-4.1 to 9.6 …
Effect of Experience and Training on the Concordance and Precision of Strain Measurements.
Negishi T, Negishi K, Thavendiranathan P, Cho GY, Popescu BA, Vinereanu D, Kurosawa K, Penicka M, Marwick TH; SUCCOUR Investigators. Negishi T, et al. JACC Cardiovasc Imaging. 2017 May;10(5):518-522. doi: 10.1016/j.jcmg.2016.06.012. Epub 2016 Oct 12. JACC Cardiovasc Imaging. 2017. PMID: 27743951 Free article.
The role of experience in the precision and validity of GLS measurement is unknown, as is the efficacy of training. METHODS: Fifty-eight readers, divided into 4 groups on the basis of their experience with GLS, calculated GLS from speckle strain analysis of 9 cases with va …
The role of experience in the precision and validity of GLS measurement is unknown, as is the efficacy of training. METHODS: Fifty-eight rea …
Noninvasive Assessment of Liver Diseases using 2D Shear Wave Elastography.
Lupșor-Platon M, Badea R, Gersak M, Maniu A, Rusu I, Suciu A, Vicas C, Stefănescu H, Urs R, Al Hajjar N. Lupșor-Platon M, et al. J Gastrointestin Liver Dis. 2016 Dec;25(4):525-532. doi: 10.15403/jgld.2014.1121.254.lup. J Gastrointestin Liver Dis. 2016. PMID: 27981309 Free article. Review.
Observer variability in RECIST-based tumour burden measurements: a meta-analysis.
Yoon SH, Kim KW, Goo JM, Kim DW, Hahn S. Yoon SH, et al. Eur J Cancer. 2016 Jan;53:5-15. doi: 10.1016/j.ejca.2015.10.014. Epub 2015 Dec 10. Eur J Cancer. 2016. PMID: 26687017 Review.
Pooled 95% LOAs of RMD in measuring unidimensional longest diameters of single lesions ranged from -22.1% (95% confidence interval [CI], -30.3% to -14.0%) to 25.4% (95% CI, 17.2% to 33.5%) between observers and -17.8% (95% CI, -23.6% to -11.9%) to 16.1 …
Pooled 95% LOAs of RMD in measuring unidimensional longest diameters of single lesions ranged from -22.1% (95% confidence inte …
Predicting lesion size during focused ultrasound thalamotomy: a review of 63 lesions over 3 clinical trials.
Bond AE, Elias WJ. Bond AE, et al. Neurosurg Focus. 2018 Feb;44(2):E5. doi: 10.3171/2017.11.FOCUS17623. Neurosurg Focus. 2018. PMID: 29385925 Review.
There was more predictability of lesion size from day 1 to day 30, with a mean reduction in lesion diameter of 11% (SD 24%). ...CONCLUSIONS At the margins, 51C temperature threshold diameters correlated best to lesion diameters mea …
There was more predictability of lesion size from day 1 to day 30, with a mean reduction in lesion diameter of 1 …
976,566 results
You have reached the last available page of results. Please see the User Guide for more information.