Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1985 1
2008 1
2009 1
2013 1
2018 3
2019 2
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

8 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Malposition of Heart and Cardiac Apex"
Page 1
Prenatal diagnosis of fetal unilateral lung agenesis complicated with cardiac malposition.
Zhang Y, Fan M, Ren WD, Xie LM, Ding CW, Sun W, Wang Y, Guo YJ, Cai AL. Zhang Y, et al. BMC Pregnancy Childbirth. 2013 Mar 26;13:79. doi: 10.1186/1471-2393-13-79. BMC Pregnancy Childbirth. 2013. PMID: 23530545 Free PMC article.
The present study describes a systematic approach for the diagnosis of fetal unilateral lung agenesis and cardiac malpositions in routine prenatal screening. METHODS: A total of 18 cases of fetal unilateral lung agenesis complicated with cardiac malpositio
The present study describes a systematic approach for the diagnosis of fetal unilateral lung agenesis and cardiac malpositions
Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices.
Sorensen EN, Kon ZN, Feller ED, Pham SM, Griffith BP. Sorensen EN, et al. Ann Thorac Surg. 2018 May;105(5):1377-1383. doi: 10.1016/j.athoracsur.2017.12.004. Epub 2018 Jan 3. Ann Thorac Surg. 2018. PMID: 29305851
METHODS: Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal computed tomography imaging planes. ...CONCLUSIONS: We found distinct device-dependent differences in inflow cannula positioning and thrombosis, …
METHODS: Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal comp …
Anatomically corrected malposition of the great arteries: diagnostic difficulties and surgical repair of associated lesions.
Colli AM, de Leval M, Somerville J. Colli AM, et al. Am J Cardiol. 1985 May 1;55(11):1367-72. doi: 10.1016/0002-9149(85)90506-5. Am J Cardiol. 1985. PMID: 3993572
Four patients, aged 5 to 14 years, had repair of abnormalities associated with anatomically "corrected malposition," a condition associated with mitral/aortic discontinuity with atrioventricular and ventriculoarterial concordance, and with the aorta lying anterior and to t …
Four patients, aged 5 to 14 years, had repair of abnormalities associated with anatomically "corrected malposition," a condition asso …
Surgical Techniques for Implanting the EVAHEART 2 Double Cuff Tipless Inflow Cannula.
Motomura T, Kelly B. Motomura T, et al. ASAIO J. 2019 Nov/Dec;65(8):e86-e89. doi: 10.1097/MAT.0000000000000914. ASAIO J. 2019. PMID: 30394886
We introduced a polymer-based patient model that mimics a dilated cardiomyopathy apex for inflow cannula implantation training. Here, we used the model to simulate appropriate and inappropriate techniques for inflow suturing. ...This misalignment can predispose to platelet …
We introduced a polymer-based patient model that mimics a dilated cardiomyopathy apex for inflow cannula implantation training. Here, …
Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD.
May-Newman K, Montes R, Campos J, Marquez-Maya N, Vu V, Zebrowski E, Motomura T, Benkowski R. May-Newman K, et al. Artif Organs. 2019 Sep;43(9):834-848. doi: 10.1111/aor.13477. Epub 2019 Jun 9. Artif Organs. 2019. PMID: 31038753
To address this, a "tipless" inflow cannula was designed for the EVAHEART LVAS, and assessed in a mock circulatory loop of the LVAD-supported heart. Customized transparent silicone models of a dilated LV were connected to the EVAHEART LVAS at the apex with a clear p …
To address this, a "tipless" inflow cannula was designed for the EVAHEART LVAS, and assessed in a mock circulatory loop of the LVAD-supporte …
Inadvertent defibrillator lead placement into the left ventricle after MitraClip implantation: A case report.
Santarpia G, Passafaro F, Pasceri E, Mongiardo A, Curcio A, Indolfi C. Santarpia G, et al. Medicine (Baltimore). 2018 May;97(19):e0733. doi: 10.1097/MD.0000000000010733. Medicine (Baltimore). 2018. PMID: 29742737 Free PMC article.
RATIONALE: Inadvertent pacemaker/defibrillator lead placement into the left ventricle is an unusual cardiac device-related complication and its diagnosis is not always easy and often misunderstood. ...A new defibrillator lead was later appropriately positioned in the ap
RATIONALE: Inadvertent pacemaker/defibrillator lead placement into the left ventricle is an unusual cardiac device-related complicati …
Malpositioning of a pacemaker lead to the left ventricle accompanied by posterior mitral leaflet injury.
Seki H, Fukui T, Shimokawa T, Manabe S, Watanabe Y, Chino K, Takanashi S. Seki H, et al. Interact Cardiovasc Thorac Surg. 2009 Feb;8(2):235-7. doi: 10.1510/icvts.2008.190793. Epub 2008 Nov 27. Interact Cardiovasc Thorac Surg. 2009. PMID: 19038982
Herein we report a rare case of a malpositioned pacemaker lead in the left ventricle, which could occur in patients with cardiac structural abnormalities. ...A malpositioned pacemaker lead in the left ventricle is a rare complication that can occur in patient …
Herein we report a rare case of a malpositioned pacemaker lead in the left ventricle, which could occur in patients with cardiac
Inadvertent Left Ventricle Endocardial or Uncomplicated Right Ventricular Pacing: How to Differentiate in the Emergency Department.
Velibey Y, Yaylak B, Guvenc TS, Cinier G, Kalenderoglu K, Guzelburc O, Yildirimturk O. Velibey Y, et al. J Emerg Med. 2018 May;54(5):e91-e95. doi: 10.1016/j.jemermed.2018.01.034. Epub 2018 Mar 6. J Emerg Med. 2018. PMID: 29523425
Diagnostic workup revealed that the lead was inadvertently located in the left ventricular apex. This case illustrates the importance of careful scrutiny of the 12-lead ECG and imaging clues in identifying lead malposition in the emergency department. ...: Because i …
Diagnostic workup revealed that the lead was inadvertently located in the left ventricular apex. This case illustrates the importance …