Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1949 1
1950 3
1951 2
1952 1
1953 2
1954 1
1955 1
1956 1
1958 1
1959 1
1961 1
1962 3
1963 1
1964 2
1966 1
1967 2
1968 8
1969 2
1971 5
1972 6
1973 7
1974 3
1975 12
1976 13
1977 13
1978 18
1979 12
1980 13
1981 25
1982 10
1983 31
1984 35
1985 30
1986 36
1987 32
1988 35
1989 49
1990 60
1991 64
1992 72
1993 61
1994 81
1995 65
1996 93
1997 97
1998 75
1999 92
2000 104
2001 116
2002 118
2003 102
2004 90
2005 130
2006 121
2007 125
2008 94
2009 102
2010 113
2011 109
2012 112
2013 152
2014 143
2015 120
2016 118
2017 174
2018 157
2019 167
2020 213
2021 211
2022 186
2023 145
2024 67

Text availability

Article attribute

Article type

Publication date

Search Results

4,088 results

Results by year

Filters applied: . Clear all
Page 1
Nebulizer systems: a new frontier for therapeutics and targeted delivery.
Khairnar SV, Jain DD, Tambe SM, Chavan YR, Amin PD. Khairnar SV, et al. Ther Deliv. 2022 Jan;13(1):31-49. doi: 10.4155/tde-2021-0070. Epub 2021 Nov 12. Ther Deliv. 2022. PMID: 34766509 Review.
Drug delivery via the pulmonary route is a cornerstone in the pharmaceutical sector as an alternative to oral and parenteral administration. Nebulizer inhalation treatment offers multiple drug administration, easily employed with tidal breathing, suitable for children and …
Drug delivery via the pulmonary route is a cornerstone in the pharmaceutical sector as an alternative to oral and parenteral administration. …
Consensus guidance of nebulizer therapy for acute rhinosinusitis.
Ohki M, Hyo Y, Yoshiyama Y, Takano H, Takahata J, Suzuki M, Takeno S, Ogoshi T, Suzuki K, Takeuchi K, Naito K, Haruna S, Fujisawa T, Yamaguchi S, Hotomi M, Kawauchi H, Kurono Y; working group of the Japan Society for Infection and Aerosol in Otorhinolaryngology. Ohki M, et al. Auris Nasus Larynx. 2020 Feb;47(1):18-24. doi: 10.1016/j.anl.2019.08.007. Epub 2019 Aug 31. Auris Nasus Larynx. 2020. PMID: 31477344
The guidance deals with the recommended applications, procedures, and safety management of nebulizer therapy for acute rhinosinusitis. In Japan, nebulizer therapy for sinusitis has been covered by public health insurance since 1958 and has been commonly carried out …
The guidance deals with the recommended applications, procedures, and safety management of nebulizer therapy for acute rhinosinusitis …
Assessing nebulizer performance.
Dolovich MB. Dolovich MB. Respir Care. 2002 Nov;47(11):1290-301; discussion 1301-4. Respir Care. 2002. PMID: 12425744 Review.
The quality of the aerosol generated by a nebulizer system is a function of its design, operating parameters, and the drug formulation to be aerosolized. ...Breath monitors that capture and feed actual patient breathing patterns into the simulator to mimic nebulizer
The quality of the aerosol generated by a nebulizer system is a function of its design, operating parameters, and the drug formulatio …
Nebulizer Care and Inhalation Technique in Children with Cystic Fibrosis.
Petrocheilou A, Kaditis AG, Troupi E, Loukou I. Petrocheilou A, et al. Children (Basel). 2020 Sep 27;7(10):E153. doi: 10.3390/children7100153. Children (Basel). 2020. PMID: 32992472 Free PMC article.
Nebulizer disinfection/maintenance score was excellent in only 31.48%. Most families kept the nebulizer clean and used appropriate disinfection method, but only half of them replaced the nebulizer and nebulizer cup at the recommended time intervals. ..
Nebulizer disinfection/maintenance score was excellent in only 31.48%. Most families kept the nebulizer clean and used appropr
Nebulizer Use by Black and Latinx Adults with Moderate to Severe Asthma.
Apter A, Carroll JK, Cardet JC, Cohen R, Colon-Moya AD, Ericson B, Forth VE, Gaefke C, Maher N, Morales-Cosme W, Rodriguez-Louis J, Tulchinsky A, Israel E. Apter A, et al. J Allergy Clin Immunol Pract. 2022 Feb;10(2):517-524.e2. doi: 10.1016/j.jaip.2021.10.016. Epub 2021 Oct 18. J Allergy Clin Immunol Pract. 2022. PMID: 34673286 Free PMC article.
Nearly all participants reported a longstanding history of nebulizer use. Participants tended to use their nebulizer at home, and some shared it with others in the home. ...The extent to which cost affected nebulizer use varied among participants. CONCLUSIONS …
Nearly all participants reported a longstanding history of nebulizer use. Participants tended to use their nebulizer at home, …
lloprost delivered via the BREELIB(TM) nebulizer: a review of the clinical evidence for efficacy and safety.
Gessler T. Gessler T. Ther Adv Respir Dis. 2019 Jan-Dec;13:1753466619835497. doi: 10.1177/1753466619835497. Ther Adv Respir Dis. 2019. PMID: 30874487 Free PMC article. Review.
The I-Neb(TM) AAD(TM), introduced in 2006, is the most commonly used nebulizer for delivering iloprost, requiring at least 6.5 min for an inhaled dose of 5 g. In order to reduce inhalation time, a portable nebulizer based on modern-device technology was developed. T …
The I-Neb(TM) AAD(TM), introduced in 2006, is the most commonly used nebulizer for delivering iloprost, requiring at least 6.5 min fo …
Preservatives in nebulizer solutions: risks without benefit.
Beasley R, Fishwick D, Miles JF, Hendeles L. Beasley R, et al. Pharmacotherapy. 1998 Jan-Feb;18(1):130-9. Pharmacotherapy. 1998. PMID: 9469687 Review.
Edetate disodium (EDTA) and benzalkonium chloride (BAC) are often present as preservative or stabilizing agents in nebulizer solutions used to treat asthma and chronic obstructive pulmonary disease. ...Inclusion of BAC (together with EDTA) in the ipratropium bromide (Atrov …
Edetate disodium (EDTA) and benzalkonium chloride (BAC) are often present as preservative or stabilizing agents in nebulizer solution …
Not all nebulizers are created equal: Considerations in choosing a nebulizer for aerosol delivery during mechanical ventilation.
MacLoughlin R, Martin-Loeches I. MacLoughlin R, et al. Expert Rev Respir Med. 2023 Feb;17(2):131-142. doi: 10.1080/17476348.2023.2183194. Epub 2023 Feb 27. Expert Rev Respir Med. 2023. PMID: 36803134 Review.
Jet nebulizers (JN) and vibrating mesh nebulizers (VMN) are the most common nebulizer types, however, despite VMN's well established superior performance, JN use remains the most commonly used of the two. In this review, we describe the key differentiators between nebul
Jet nebulizers (JN) and vibrating mesh nebulizers (VMN) are the most common nebulizer types, however, despite VMN's well established …
Nebulizer Cleaning Practices and Adherence to Nebulized Therapies in People With Cystic Fibrosis When Traveling.
O'Doherty M, O'Neill D, Rendall JC, Moore JE, Millar BC. O'Doherty M, et al. Respir Care. 2022 Jul 26:respcare.09582. doi: 10.4187/respcare.09582. Online ahead of print. Respir Care. 2022. PMID: 35882472
When traveling, 38% (25/66) of respondents indicated that nebulized therapy was not performed during travel. The most common method of nebulizer maintenance while traveling was washing with soap and water (43%), followed by boiling water (18%), as well as the employment of …
When traveling, 38% (25/66) of respondents indicated that nebulized therapy was not performed during travel. The most common method of ne
An Automated Jet Nebulizer with Dynamic Flow Regulation.
Dampage U, Ariyasinghe M, Pulleperuma S. Dampage U, et al. J Pharm Innov. 2022;17(3):725-735. doi: 10.1007/s12247-021-09557-2. Epub 2021 Apr 7. J Pharm Innov. 2022. PMID: 33841586 Free PMC article.
PURPOSE: The present study is focused on designing an automated jet nebulizer that possesses the capability of dynamic flow regulation. ...RESULTS: A laminar flow was obtained from the outlet of the compressor towards the nebulizer tubing, and a turbulent flow was o …
PURPOSE: The present study is focused on designing an automated jet nebulizer that possesses the capability of dynamic flow regulatio …
4,088 results