Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1987 1
1991 1
1993 3
1995 2
1996 1
1999 5
2000 2
2001 4
2002 3
2003 1
2004 4
2005 3
2006 4
2007 3
2008 5
2009 4
2010 8
2011 6
2012 7
2013 8
2014 6
2015 9
2016 7
2017 12
2018 4
2019 12
2020 3
2021 1
2022 4
2023 6
2024 3

Text availability

Article attribute

Article type

Publication date

Search Results

124 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Nuclear Cataract Grade 2"
Page 1
AI-based diagnosis of nuclear cataract from slit-lamp videos.
Shimizu E, Tanji M, Nakayama S, Ishikawa T, Agata N, Yokoiwa R, Nishimura H, Khemlani RJ, Sato S, Hanyuda A, Sato Y. Shimizu E, et al. Sci Rep. 2023 Dec 12;13(1):22046. doi: 10.1038/s41598-023-49563-7. Sci Rep. 2023. PMID: 38086904 Free PMC article.
Ophthalmologists graded the nuclear cataracts (NUCs) using the cataract grading scale of the World Health Organization. ...The results of individual cataract gradings were: NUC 0: area under the curve (AUC) = 0.967; NUC 1: AUC = 0. …
Ophthalmologists graded the nuclear cataracts (NUCs) using the cataract grading scale of the World Health …
Exome Array Analysis of Nuclear Lens Opacity.
Loomis SJ, Klein AP, Lee KE, Chen F, Bomotti S, Truitt B, Iyengar SK, Klein R, Klein BEK, Duggal P. Loomis SJ, et al. Ophthalmic Epidemiol. 2018 Jun;25(3):215-219. doi: 10.1080/09286586.2017.1406122. Epub 2017 Nov 28. Ophthalmic Epidemiol. 2018. PMID: 29182452 Free PMC article.
PURPOSE: Nuclear cataract is the most common subtype of age-related cataract, the leading cause of blindness worldwide. ...METHODS: We analyzed Illumina Human Exome Array data for 1,488 participants of European ancestry in the Beaver Dam Eye Study who were wi …
PURPOSE: Nuclear cataract is the most common subtype of age-related cataract, the leading cause of blindness worldwide. …
Objective assessment of nuclear cataract: comparison of double-pass and Scheimpflug systems.
Lim SA, Hwang J, Hwang KY, Chung SH. Lim SA, et al. J Cataract Refract Surg. 2014 May;40(5):716-21. doi: 10.1016/j.jcrs.2013.10.032. J Cataract Refract Surg. 2014. PMID: 24767907
PURPOSE: To compare the objective assessment of lens density by 2 systems (double-pass Optical Quality Analysis System and Pentacam Scheimpflug) in eyes with age-related nuclear cataract. ...CONCLUSIONS: The OSI based on the double-pass system was correlated …
PURPOSE: To compare the objective assessment of lens density by 2 systems (double-pass Optical Quality Analysis System and Pentacam S …
Cataract quantification using swept-source optical coherence tomography.
Brás JEG, Sickenberger W, Hirnschall N, Findl O. Brás JEG, et al. J Cataract Refract Surg. 2018 Dec;44(12):1478-1481. doi: 10.1016/j.jcrs.2018.08.009. Epub 2018 Nov 2. J Cataract Refract Surg. 2018. PMID: 30392762
The pixel intensity unit of the lens nucleus (OCT-based cataract quantification system score) was equated to the clinician's subjective nuclear opalescence grading. RESULTS: The study evaluated 186 eyes (113 patients). The correlation between the independent …
The pixel intensity unit of the lens nucleus (OCT-based cataract quantification system score) was equated to the clinician's subjecti …
Quantitating cataract and nuclear brunescence, the Harvard and LOCS systems.
Chylack LT Jr, Wolfe JK, Friend J, Khu PM, Singer DM, McCarthy D, del Carmen J, Rosner B. Chylack LT Jr, et al. Optom Vis Sci. 1993 Nov;70(11):886-95. doi: 10.1097/00006324-199311000-00005. Optom Vis Sci. 1993. PMID: 8302524
The subjective systems are used to classify nuclear color, nuclear opalescence, cortical cataract, and posterior subcapsular cataract. ...The computerized objective system are: (1) fast spectral scanning colorimetry (FSSC) for assessment of nuclear
The subjective systems are used to classify nuclear color, nuclear opalescence, cortical cataract, and posterior subcap …
The prevalence of cataract in a population with and without type 2 diabetes mellitus.
Olafsdottir E, Andersson DK, Stefánsson E. Olafsdottir E, et al. Acta Ophthalmol. 2012 Jun;90(4):334-40. doi: 10.1111/j.1755-3768.2011.02326.x. Epub 2011 Dec 16. Acta Ophthalmol. 2012. PMID: 22176834 Free article.
RESULTS: The prevalence of significant cortical, posterior subcapsular and nuclear cataract was 65.5%, 42.5% and 48.0%, respectively, in the type 2 diabetes population in Laxa. ...In the diabetic population, all types of cataract were likewise strongly …
RESULTS: The prevalence of significant cortical, posterior subcapsular and nuclear cataract was 65.5%, 42.5% and 48.0%, respec …
Myopia and the long-term incidence of cataract and cataract surgery: the Blue Mountains Eye Study.
Kanthan GL, Mitchell P, Rochtchina E, Cumming RG, Wang JJ. Kanthan GL, et al. Clin Exp Ophthalmol. 2014 May-Jun;42(4):347-53. doi: 10.1111/ceo.12206. Epub 2013 Oct 11. Clin Exp Ophthalmol. 2014. PMID: 24024555
Lens photographs were taken at each visit and assessed using the Wisconsin Cataract Grading System. MAIN OUTCOME MEASURES: Long-term incidence of cataract and cataract surgery. ...Either any (odds ratio 1.35, confidence interval 1.08-1.69) or moderate …
Lens photographs were taken at each visit and assessed using the Wisconsin Cataract Grading System. MAIN OUTCOME MEASURES: Lon …
A case report of iridoschisis and cataract: a challenging diagnosis.
Katipoğlu Z, Turan M. Katipoğlu Z, et al. Int Ophthalmol. 2024 Feb 7;44(1):26. doi: 10.1007/s10792-024-03001-3. Int Ophthalmol. 2024. PMID: 38326697
PURPOSE: To report the cataract surgery of a 79-year-old female patient with iridoschisis and senile nuclear cataracts. OBSERVATIONS: Ophthalmologic examination of the 79-year-old female patient who came to our clinic with complaints of decreased vision in th …
PURPOSE: To report the cataract surgery of a 79-year-old female patient with iridoschisis and senile nuclear cataracts. …
Comparing retinal sensitivities on blue-on-yellow and green-on-yellow perimetry in glaucoma suspects.
Pokal U, Swathi N, Rajalakshmi AR, Lokeshmaran A. Pokal U, et al. Indian J Ophthalmol. 2022 Oct;70(10):3550-3555. doi: 10.4103/ijo.IJO_944_22. Indian J Ophthalmol. 2022. PMID: 36190045 Free PMC article.
Twenty-one eyes had clear lens or pseudophakia. Twenty-six eyes had lower grades of nuclear sclerosis (NO2NC2, NO3NC3) and eight eyes had higher grades of cataract (NO4NC4, NO5NC5). ...CONCLUSION: BYP and GYP show good agreement. They are comparable in …
Twenty-one eyes had clear lens or pseudophakia. Twenty-six eyes had lower grades of nuclear sclerosis (NO2NC2, NO3NC3) and eig …
Risk factors for and diagnosis of pseudophakic cystoid macular edema after cataract surgery in diabetic patients.
Yang J, Cai L, Sun Z, Ye H, Fan Q, Zhang K, Lu W, Lu Y. Yang J, et al. J Cataract Refract Surg. 2017 Feb;43(2):207-214. doi: 10.1016/j.jcrs.2016.11.047. J Cataract Refract Surg. 2017. PMID: 28366368
RESULTS: The duration, type of diabetes, stage of diabetic retinopathy, nuclear opalescence grading, glycosylated hemoglobin A(1c) (HbA(1c)), and ultrasound time were correlated with the change in foveal thickness and macular sensitivity after cataract surger …
RESULTS: The duration, type of diabetes, stage of diabetic retinopathy, nuclear opalescence grading, glycosylated hemoglobin A …
124 results