Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1991 1
1993 1
2001 1
2003 1
2005 1
2006 4
2007 1
2008 1
2010 2
2011 1
2013 1
2014 1
2017 1
2018 4
2019 4
2021 3
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

24 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Short distal phalanx of finger"
Page 1
Back to basics with distal thumb reconstruction. Easy management of the incomplete amputation.
Losco L, Kaciulyte J, Delia G, Bolletta A, Lo Torto F, Di Taranto G, Ribuffo D, Cigna E. Losco L, et al. J Invest Surg. 2021 Jun;34(6):595-600. doi: 10.1080/08941939.2019.1672840. Epub 2019 Oct 7. J Invest Surg. 2021. PMID: 31590590
The distal thumb was held by a short tissue islet, nor neurovascular bundle, nor dorsal vein was included. ...Partial distal thumb necrosis was observed in six cases (40%); they healed by secondary intention. ...
The distal thumb was held by a short tissue islet, nor neurovascular bundle, nor dorsal vein was included. ...Partial dista
New Developments Are Improving Flexor Tendon Repair.
Tang JB. Tang JB. Plast Reconstr Surg. 2018 Jun;141(6):1427-1437. doi: 10.1097/PRS.0000000000004416. Plast Reconstr Surg. 2018. PMID: 29579022
., the A2 pulley) can be vented partially with an incision over its distal or proximal sheath no longer than 1.5 to 2 cm; the annular pulley over the middle phalanx (i.e., the A4 pulley) can be vented entirely. Surgeons have not observed adverse effects on ha …
., the A2 pulley) can be vented partially with an incision over its distal or proximal sheath no longer than 1.5 to 2 cm; the annular …
Distal unicondylar fractures of the proximal phalanx.
Weiss AP, Hastings H 2nd. Weiss AP, et al. J Hand Surg Am. 1993 Jul;18(4):594-9. doi: 10.1016/0363-5023(93)90297-G. J Hand Surg Am. 1993. PMID: 8349964
The records of 38 consecutive patients (38 fractures) who underwent treatment for distal unicondylar fractures of the proximal phalanx were reviewed to evaluate fracture characteristics, mechanism of injury, treatment options, and functional outcomes. ...Class IV fr …
The records of 38 consecutive patients (38 fractures) who underwent treatment for distal unicondylar fractures of the proximal pha
A molecular and clinical study of Larsen syndrome caused by mutations in FLNB.
Bicknell LS, Farrington-Rock C, Shafeghati Y, Rump P, Alanay Y, Alembik Y, Al-Madani N, Firth H, Karimi-Nejad MH, Kim CA, Leask K, Maisenbacher M, Moran E, Pappas JG, Prontera P, de Ravel T, Fryns JP, Sweeney E, Fryer A, Unger S, Wilson LC, Lachman RS, Rimoin DL, Cohn DH, Krakow D, Robertson SP. Bicknell LS, et al. J Med Genet. 2007 Feb;44(2):89-98. doi: 10.1136/jmg.2006.043687. Epub 2006 Jun 26. J Med Genet. 2007. PMID: 16801345 Free PMC article.
RESULTS AND DISCUSSION: The clinical signs most frequently associated with a FLNB mutation are the presence of supernumerary carpal and tarsal bones and short, broad, spatulate distal phalanges, particularly of the thumb. ...Three mutations are recurrent, wit …
RESULTS AND DISCUSSION: The clinical signs most frequently associated with a FLNB mutation are the presence of supernumerary carpal and tars …
Treatment of proximal phalanx fractures: transarticular pinning the metacarpophalangeal joint or cross pinning from the base of the proximal phalanx-a prospective study.
Saied AR, Sabet Jahromi M. Saied AR, et al. Eur J Trauma Emerg Surg. 2019 Aug;45(4):737-743. doi: 10.1007/s00068-018-0927-6. Epub 2018 Feb 27. Eur J Trauma Emerg Surg. 2019. PMID: 29487957 Clinical Trial.
MATERIALS AND METHODS: This study was a prospective one on patients with proximal phalanx transverse or short oblique fractures. In one of the groups we used parallel pins from metacarpal head through MCP joint to proximal phalanx. In the second, we used two …
MATERIALS AND METHODS: This study was a prospective one on patients with proximal phalanx transverse or short oblique fracture …
Lengths, girths, and diameters of children's fingers from 3 to 10 years of age.
Hohendorff B, Weidermann C, Burkhart KJ, Rommens PM, Prommersberger KJ, Konerding MA. Hohendorff B, et al. Ann Anat. 2010 May 20;192(3):156-61. doi: 10.1016/j.aanat.2010.03.002. Epub 2010 Apr 3. Ann Anat. 2010. PMID: 20399088
A total of 160 children (78 girls, 82 boys) were examined in a cross-sectional investigation. The length of each finger of the right hand of every child was measured, as were the girths of the proximal, middle, and distal phalanges, and of the proximal and …
A total of 160 children (78 girls, 82 boys) were examined in a cross-sectional investigation. The length of each finger of the right …
Comparison of low-profile plate-screw and Kirschner-wire osteosynthesis outcomes in extra-articular unstable proximal phalangeal fractures.
Köse A, Topal M, Engin MÇ, Şencan A, Dinçer R, Baran T. Köse A, et al. Eur J Orthop Surg Traumatol. 2019 Apr;29(3):597-604. doi: 10.1007/s00590-018-2342-4. Epub 2018 Nov 13. Eur J Orthop Surg Traumatol. 2019. PMID: 30426217
Active and passive metacarpophalangeal joint and interphalangeal joint range of motions, total joint range of motion, measurement of grip strength for fractured and healthy hands, visual analog scoring, disabilities of the arm, shoulder, and hand scores, measurement of dis …
Active and passive metacarpophalangeal joint and interphalangeal joint range of motions, total joint range of motion, measurement of grip st …
Use of a relative motion flexion orthosis with dorsal hood to protect a middle phalanx finger fracture and zone III extensor tendon repair, while correcting a secondary fixed flexion proximal interphalangeal joint flexion contracture: A case report.
Johnson C, Manolopoulos K. Johnson C, et al. J Hand Ther. 2023 Apr-Jun;36(2):448-455. doi: 10.1016/j.jht.2022.12.005. Epub 2023 Apr 27. J Hand Ther. 2023. PMID: 37117068
PURPOSE: A case report to examine the effectiveness of using single orthosis to treat an index finger following a combined zone III extension tendon repair, surgically stabilized second phalanx fracture and PIPJ flexion contracture. ...RESULTS: At 20 weeks post init …
PURPOSE: A case report to examine the effectiveness of using single orthosis to treat an index finger following a combined zone III e …
Pyrolytic carbon resurfacing arthroplasty for osteoarthritis of the proximal interphalangeal joint of the finger.
Sweets TM, Stern PJ. Sweets TM, et al. J Bone Joint Surg Am. 2011 Aug 3;93(15):1417-25. doi: 10.2106/JBJS.J.00832. J Bone Joint Surg Am. 2011. PMID: 21915547
Data from the Michigan Hand Outcomes Questionnaire were compared for the involved and noninvolved hands of the fifteen patients who received implants unilaterally. Significant deficits were observed in the total outcome score, activities of daily living, function, a …
Data from the Michigan Hand Outcomes Questionnaire were compared for the involved and noninvolved hands of the fifteen patients who received …
K-wire fixation for extraarticular transverse/short oblique fractures of the shaft of the middle phalanx associated with extensor tendon injury.
Al-Qattan MM. Al-Qattan MM. J Hand Surg Eur Vol. 2008 Oct;33(5):561-5. doi: 10.1177/1753193408090147. Epub 2008 Jun 25. J Hand Surg Eur Vol. 2008. PMID: 18579625
In a prospective study, 22 cases of extraarticular transverse/short oblique fractures of the shaft of the middle phalanx associated with extensor tendon injury had fixation of the fracture as well as immobilisation of the distal interphalangeal joint using a …
In a prospective study, 22 cases of extraarticular transverse/short oblique fractures of the shaft of the middle phalanx assoc …
24 results