Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2004 1
2005 1
2015 2
2016 1
2019 1
2021 1
2022 4
2023 4
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

14 results

Results by year

Filters applied: . Clear all
Page 1
Association between sick sinus syndrome and atrial fibrillation: A systematic review and meta-analysis.
Liu Y, Zheng Y, Tse G, Bazoukis G, Letsas K, Goudis C, Korantzopoulos P, Li G, Liu T. Liu Y, et al. Int J Cardiol. 2023 Jun 15;381:20-36. doi: 10.1016/j.ijcard.2023.03.066. Epub 2023 Apr 5. Int J Cardiol. 2023. PMID: 37023861
AIMS: Sick sinus syndrome (SSS) and atrial fibrillation (AF) frequently coexist and show a bidirectional relationship. ...
AIMS: Sick sinus syndrome (SSS) and atrial fibrillation (AF) frequently coexist and show a bidirectional relationship. …
Dual-chamber pacemakers for treating symptomatic bradycardia due to sick sinus syndrome without atrioventricular block: a systematic review and economic evaluation.
Edwards SJ, Karner C, Trevor N, Wakefield V, Salih F. Edwards SJ, et al. Health Technol Assess. 2015 Aug;19(65):1-210. doi: 10.3310/hta19650. Health Technol Assess. 2015. PMID: 26293406 Free PMC article. Review.
BACKGROUND: Bradycardia [resting heart rate below 60 beats per minute (b.p.m.)] can be caused by conditions affecting the natural pacemakers of the heart, such as sick sinus syndrome (SSS) and atrioventricular (AV) blocks. People suffering from bradycardia ma …
BACKGROUND: Bradycardia [resting heart rate below 60 beats per minute (b.p.m.)] can be caused by conditions affecting the natural pacemakers …
The effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber pacemakers for bradycardia due to atrioventricular block or sick sinus syndrome: systematic review and economic evaluation.
Castelnuovo E, Stein K, Pitt M, Garside R, Payne E. Castelnuovo E, et al. Health Technol Assess. 2005 Nov;9(43):iii, xi-xiii, 1-246. doi: 10.3310/hta9430. Health Technol Assess. 2005. PMID: 16266560 Free article. Review.
OBJECTIVES: To estimate the effectiveness and cost-effectiveness of dual-chamber pacemakers versus single-chamber atrial or single-chamber ventricular pacemakers in the treatment of bradycardia due to sick sinus syndrome (SSS) or atrioventricular block (AVB). …
OBJECTIVES: To estimate the effectiveness and cost-effectiveness of dual-chamber pacemakers versus single-chamber atrial or single-chamber v …
Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.
Dretzke J, Toff WD, Lip GY, Raftery J, Fry-Smith A, Taylor R. Dretzke J, et al. Cochrane Database Syst Rev. 2004;2004(2):CD003710. doi: 10.1002/14651858.CD003710.pub2. Cochrane Database Syst Rev. 2004. PMID: 15106214 Free PMC article. Review.
OBJECTIVES: The objective of this review was to assess the short- and long-term clinical effectiveness of dual chamber pacemakers compared to single chamber ventricular pacemakers in adults with AV block, sick sinus syndrome or both. An additional objective w …
OBJECTIVES: The objective of this review was to assess the short- and long-term clinical effectiveness of dual chamber pacemakers compared t …
Chronic Arrhythmias in the Setting of Heterotaxy: Differences between Right and Left Isomerism.
Loomba RS, Willes RJ, Kovach JR, Anderson RH. Loomba RS, et al. Congenit Heart Dis. 2016 Jan-Feb;11(1):7-18. doi: 10.1111/chd.12288. Epub 2015 Jul 29. Congenit Heart Dis. 2016. PMID: 26219620 Review.
Those with left isomerism were more likely to have atrioventricular block, intraventricular conduction delay, sick sinus syndrome, and atrioventricular nodal reentry tachycardia. ...
Those with left isomerism were more likely to have atrioventricular block, intraventricular conduction delay, sick sinus sy
Tricuspid regurgitation associated with implantable electrical device insertion: A systematic review and meta-analysis.
Tatum R, Maynes EJ, Wood CT, Deb AK, Austin MA, O'Malley TJ, Choi JH, Massey HT, Morris RJ, Pavri BB, Tchantchaleishvili V. Tatum R, et al. Pacing Clin Electrophysiol. 2021 Aug;44(8):1297-1302. doi: 10.1111/pace.14287. Epub 2021 Jul 1. Pacing Clin Electrophysiol. 2021. PMID: 34081789
Devices implanted included ICD in 57% [95%CI: 43-70] and PPM in 41% [95%CI: 31-52]. The most common indications for pacemaker implantation were sick sinus syndrome in 22% [95% CI: 22-37] and AV block in 21% [95%CI:12-34. ...
Devices implanted included ICD in 57% [95%CI: 43-70] and PPM in 41% [95%CI: 31-52]. The most common indications for pacemaker implantation w …
14 results