Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1974 1
1976 2
1977 1
1982 1
1983 1
1987 1
1988 1
1993 1
1995 1
2010 1
2011 2
2012 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

13 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Thickened mitral valve cusp"
Page 1
Abnormal aortic valve echoes in mitral prolapse. Echocardiographic features of floppy aortic valve.
Rodger JC, Morley P. Rodger JC, et al. Br Heart J. 1982 Apr;47(4):337-43. doi: 10.1136/hrt.47.4.337. Br Heart J. 1982. PMID: 7066118 Free PMC article.
The following distinctive combination of M-mode and two dimensional echocardiographic abnormalities of the aortic valve was observed in a group of 12 patients, of whom 11 had mitral valve prolapse. ...It is, therefore, further suggested that the investigation …
The following distinctive combination of M-mode and two dimensional echocardiographic abnormalities of the aortic valve was observed …
Aortic stenosis: echocardiographic cusp separation and surgical description of aortic valve in 22 patients.
Chang S, Clements S, Chang J. Chang S, et al. Am J Cardiol. 1977 Apr;39(4):499-504. doi: 10.1016/s0002-9149(77)80157-4. Am J Cardiol. 1977. PMID: 848433
To test the validity of this index, 22 patients--12 (55 percent) with isolated aortic valve disease and 10 (45 percent) with aortic stenosis associated with mitral or coronary artery disease--underwent M mode echocardiographic examination before aortic valve
To test the validity of this index, 22 patients--12 (55 percent) with isolated aortic valve disease and 10 (45 percent) with aortic s …
Pathological features of hypertrophic obstructive cardiomyopathy.
Davies MJ, Pomerance A, Teare RD. Davies MJ, et al. J Clin Pathol. 1974 Jul;27(7):529-35. doi: 10.1136/jcp.27.7.529. J Clin Pathol. 1974. PMID: 4472994 Free PMC article.
Eighteen of the hearts showed a distinctive band of fibrous thickening below the aortic valve. This was a mirror image of the free edge of the anterior mitral cusp, had the microscopic features of an endocardial friction lesion, and was clearly the mor …
Eighteen of the hearts showed a distinctive band of fibrous thickening below the aortic valve. This was a mirror image of the …
Doppler and echocardiographic features of normal and dysfunctioning bioprosthetic valves.
Alam M, Rosman HS, Lakier JB, Kemp S, Khaja F, Hautamaki K, Magilligan DJ Jr, Stein PD. Alam M, et al. J Am Coll Cardiol. 1987 Oct;10(4):851-8. doi: 10.1016/s0735-1097(87)80280-2. J Am Coll Cardiol. 1987. PMID: 3309005 Free article.
Echocardiographic and Doppler studies were performed on 183 clinically normal and 58 severely dysfunctioning bioprosthetic mitral, aortic and tricuspid valves. The valve dysfunction resulted from spontaneous cusp degeneration in 49 instances and from paravalv …
Echocardiographic and Doppler studies were performed on 183 clinically normal and 58 severely dysfunctioning bioprosthetic mitral, ao …
Upregulation of the 5-lipoxygenase pathway in human aortic valves correlates with severity of stenosis and leads to leukotriene-induced effects on valvular myofibroblasts.
Nagy E, Andersson DC, Caidahl K, Eriksson MJ, Eriksson P, Franco-Cereceda A, Hansson GK, Bäck M. Nagy E, et al. Circulation. 2011 Mar 29;123(12):1316-25. doi: 10.1161/CIRCULATIONAHA.110.966846. Epub 2011 Mar 14. Circulation. 2011. PMID: 21403093
BACKGROUND: The development of aortic valve stenosis is not only associated with calcification and extracellular matrix remodeling, but also with inflammation. ...METHODS AND RESULTS: After macroscopic dissection of surgically removed human aortic valves, RNA was extracted …
BACKGROUND: The development of aortic valve stenosis is not only associated with calcification and extracellular matrix remodeling, b …
Assessment of cardiac valve dysfunction in patients receiving cabergoline treatment for hyperprolactinaemia.
Tan T, Cabrita IZ, Hensman D, Grogono J, Dhillo WS, Baynes KC, Eliahoo J, Meeran K, Robinson S, Nihoyannopoulos P, Martin NM. Tan T, et al. Clin Endocrinol (Oxf). 2010 Sep;73(3):369-74. doi: 10.1111/j.1365-2265.2010.03827.x. Epub 2010 Jun 9. Clin Endocrinol (Oxf). 2010. PMID: 20550538
There was only one case of tricuspid regurgitation, which was mild and observed in a cabergoline-treated patient. Nodular thickening of the right coronary cusp, noncoronary cusp or left coronary cusp of the aortic valve was observed at a similar …
There was only one case of tricuspid regurgitation, which was mild and observed in a cabergoline-treated patient. Nodular thickening
Detection of bioprosthetic valve infection by image fusion of (18)fluorodeoxyglucose-positron emission tomography and computed tomography.
Plank F, Mueller S, Uprimny C, Hangler H, Feuchtner G. Plank F, et al. Interact Cardiovasc Thorac Surg. 2012 Mar;14(3):364-6. doi: 10.1093/icvts/ivr107. Epub 2011 Dec 16. Interact Cardiovasc Thorac Surg. 2012. PMID: 22180605 Free PMC article.
A 63-year old male with prior bioprosthetic mitral valve replacement and coronary artery bypass graft surgery presented with dyspnea. ...There was no tracer-uptake surrounding the leak excluding an abscess. However, an increased (18)FDG-tracer uptake at the thick
A 63-year old male with prior bioprosthetic mitral valve replacement and coronary artery bypass graft surgery presented with d …
Echocardiographic evaluation of porcine bioprosthetic valves: experience with 309 normal and 59 dysfunctioning valves.
Alam M, Lakier JB, Pickard SD, Goldstein S. Alam M, et al. Am J Cardiol. 1983 Aug;52(3):309-15. doi: 10.1016/0002-9149(83)90129-7. Am J Cardiol. 1983. PMID: 6869278
The study includes 309 normal and 59 dysfunctioning valves. Valve dysfunction resulted from spontaneous cusp degeneration in 39 (34 valve regurgitations, 5 stenoses), infective endocarditis in 12, paravalvular regurgitation in 5, regurgitation of redundant cu …
The study includes 309 normal and 59 dysfunctioning valves. Valve dysfunction resulted from spontaneous cusp degeneration in 3 …
Clinical study of 47 patients with reoperation after open mitral commissurotomy.
Isomura T, Hisatomi K, Satoh T, Hirano A, Kosuga K, Ohishi K. Isomura T, et al. J Cardiovasc Surg (Torino). 1993 Aug;34(4):327-31. J Cardiovasc Surg (Torino). 1993. PMID: 8227114
The diagnosis before OMC consisted of pure MS in 38 patients, with mild mitral regurgitation (MR) in 8 and with moderate MR in 1. At OMC the diameter of the mitral orifice was a mean of 1.3 +/- 0.5 cm and a mobile cusp was found in 12 and a thickened
The diagnosis before OMC consisted of pure MS in 38 patients, with mild mitral regurgitation (MR) in 8 and with moderate MR in 1. At …
Cross-sectional echocardiographic localization of sites of left ventricular outflow tract obstruction.
Williams DE, Sahn DJ, Friedman WF. Williams DE, et al. Am J Cardiol. 1976 Feb;37(2):250-5. doi: 10.1016/0002-9149(76)90320-9. Am J Cardiol. 1976. PMID: 942808
In valvular aortic stenosis, echocardiographic diagnostic findings included poststenotic dilatation of the ascending aorta, thickened aortic cusp tissue and increased superior-inferior cusp excursion (doming). ...In patients with discrete subvalvular aortic s …
In valvular aortic stenosis, echocardiographic diagnostic findings included poststenotic dilatation of the ascending aorta, thickened
13 results