Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1975 1
1979 1
1985 2
1986 3
1989 1
1990 3
1991 1
1994 2
1996 2
1998 1
1999 1
2001 6
2002 3
2003 1
2004 3
2005 4
2006 2
2007 4
2008 10
2009 6
2010 11
2011 7
2012 5
2013 15
2014 9
2015 4
2016 13
2017 11
2018 7
2019 8
2020 10
2021 15
2022 7
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

157 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "Titanium metallic discoloration"
Page 1
Metallic discoloration on the right shin caused by titanium alloy prostheses in a patient with right total knee replacement.
Park JY, Shin DH, Choi JS, Kim KH. Park JY, et al. Ann Dermatol. 2013 Aug;25(3):356-9. doi: 10.5021/ad.2013.25.3.356. Epub 2013 Aug 13. Ann Dermatol. 2013. PMID: 24003281 Free PMC article.
The differential diagnosis of bluish-gray pigmentation of the skin includes dermal melanocytosis, malignant melanoma and metallic discoloration. Of these disorders, metallic discoloration, which develops from deposits of fine metallic particles …
The differential diagnosis of bluish-gray pigmentation of the skin includes dermal melanocytosis, malignant melanoma and metallic
Optical Efficacy of Titanium Nitride-Coated Abutment Material on Soft Tissue Discoloration: A Spectrophotometric In Vitro Analysis.
Gehrke P, Zimmermann KP, Weinhold O, Dhom G, Fischer C, Sader R. Gehrke P, et al. Int J Oral Maxillofac Implants. 2021 Jul-Aug;36(4):e91-e96. doi: 10.11607/jomi.8537. Int J Oral Maxillofac Implants. 2021. PMID: 34411214
PURPOSE: The objective of this investigation was to assess the extent of mucosal discoloration caused by different CAD/CAM abutment materials and to determine the influence of mucosa thickness on the subsequent color, with a particular focus on titanium nitride. ... …
PURPOSE: The objective of this investigation was to assess the extent of mucosal discoloration caused by different CAD/CAM abutment m …
Present status of titanium removable dentures--a review of the literature.
Ohkubo C, Hanatani S, Hosoi T. Ohkubo C, et al. J Oral Rehabil. 2008 Sep;35(9):706-14. doi: 10.1111/j.1365-2842.2007.01821.x. J Oral Rehabil. 2008. PMID: 18793355 Review.
However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of clasp retention, tendency for plaque to adhere to the surface, detachment of the denture base resin, and severe wear of titanium teeth, …
However, the clinical problems, such as discoloration of the titanium surfaces, unpleasant metal taste, decrease of cla …
Discoloration of titanium alloy in acidic saline solutions with peroxide.
Takemoto S, Hattori M, Yoshinari M, Kawada E, Oda Y. Takemoto S, et al. Dent Mater J. 2013;32(1):19-24. doi: 10.4012/dmj.2012-194. Dent Mater J. 2013. PMID: 23370866 Free article.
Seven types of titanium alloy were immersed in saline solutions with varying levels of pH and hydrogen peroxide content, and resulting differences in color and release of metallic elements determined in each alloy. ...The formation of a thick oxide film was observed …
Seven types of titanium alloy were immersed in saline solutions with varying levels of pH and hydrogen peroxide content, and resultin …
Discoloration of the Peri-implant Mucosa Caused by Zirconia and Titanium Implants.
Thoma DS, Ioannidis A, Cathomen E, Hämmerle CH, Hüsler J, Jung RE. Thoma DS, et al. Int J Periodontics Restorative Dent. 2016 Jan-Feb;36(1):39-45. doi: 10.11607/prd.2663. Int J Periodontics Restorative Dent. 2016. PMID: 26697552
The aim of the present study was to assess the discoloration of the peri-implant mucosa caused by zirconia (Zr) and titanium (Ti) dental implants with and without soft tissue grafting (STG). ...In conjunction with a STG, deltaE values amounted to 5.31 3.50 (Ti) and …
The aim of the present study was to assess the discoloration of the peri-implant mucosa caused by zirconia (Zr) and titanium ( …
Discoloration and dissolution of titanium and titanium alloys with immersion in peroxide- or fluoride-containing solutions.
Noguchi T, Takemoto S, Hattori M, Yoshinari M, Kawada E, Oda Y. Noguchi T, et al. Dent Mater J. 2008 Jan;27(1):117-23. doi: 10.4012/dmj.27.117. Dent Mater J. 2008. PMID: 18309620 Free article.
This study compared differences in discoloration and dissolution in several titanium alloys with immersion in peroxide- or fluoride-containing solution. Commercially pure titanium (CP-Ti) and six titanium-based alloys were used: Ti-0.15Pd, Ti-6Al-4V, T …
This study compared differences in discoloration and dissolution in several titanium alloys with immersion in peroxide- or flu …
Mechanical and biological complications after implantoplasty-A systematic review.
Stavropoulos A, Bertl K, Eren S, Gotfredsen K. Stavropoulos A, et al. Clin Oral Implants Res. 2019 Sep;30(9):833-848. doi: 10.1111/clr.13499. Epub 2019 Jul 17. Clin Oral Implants Res. 2019. PMID: 31254417 Review.
Laboratory studies have shown that implantoplasty does not result in temperature increase, provided proper cooling is used, but leads in reduced implant strength in "standard" dimension implants; further, preclinical studies have shown titanium particle deposition in the s …
Laboratory studies have shown that implantoplasty does not result in temperature increase, provided proper cooling is used, but leads in red …
The role of bacterial corrosion on recolonization of titanium implant surfaces: An in vitro study.
Weller J, Vasudevan P, Kreikemeyer B, Ekat K, Jackszis M, Springer A, Chatzivasileiou K, Lang H. Weller J, et al. Clin Implant Dent Relat Res. 2022 Oct;24(5):664-675. doi: 10.1111/cid.13114. Epub 2022 Jun 16. Clin Implant Dent Relat Res. 2022. PMID: 35709098

RESULTS: S. sanguinis and P. gingivalis formed stable biofilms on the titanium samples. Bacterial corrosion led to a significant increase in titanium ion release from these titanium plates (p < 0.01), which was significantly higher under aerobic conditions

RESULTS: S. sanguinis and P. gingivalis formed stable biofilms on the titanium samples. Bacterial corrosion led to a significant incr …
Future prospects of zirconia for oral implants -A review.
Yoshinari M. Yoshinari M. Dent Mater J. 2020 Jan 31;39(1):37-45. doi: 10.4012/dmj.2019-151. Epub 2019 Oct 30. Dent Mater J. 2020. PMID: 31666487 Free article. Review.
Zirconia have been applied to dental implants as well as fixed dental prostheses due to their mechanical, esthetic and biocompatible performance. Moreover, they offer an advantage over titanium (Ti) implants, in that there is no risk of discoloration or hypersensiti …
Zirconia have been applied to dental implants as well as fixed dental prostheses due to their mechanical, esthetic and biocompatible perform …
Nonalloyed titanium as a bioinert metal--a review.
Tschernitschek H, Borchers L, Geurtsen W. Tschernitschek H, et al. Quintessence Int. 2005 Jul-Aug;36(7-8):523-30. Quintessence Int. 2005. PMID: 15997933 Review.
A thorough review of the medical and dental literature reveals, however, that titanium can also cause chemical-biological interactions. Tissue discoloration and allergic reactions in patients who have come in contact with titanium have been reported. The bios …
A thorough review of the medical and dental literature reveals, however, that titanium can also cause chemical-biological interaction …
157 results