Management of Conduction Disturbances Associated With Transcatheter Aortic Valve Replacement: JACC Scientific Expert Panel.
Rodés-Cabau J, Ellenbogen KA, Krahn AD, Latib A, Mack M, Mittal S, Muntané-Carol G, Nazif TM, Sondergaard L, Urena M, Windecker S, Philippon F.
Rodés-Cabau J, et al.
J Am Coll Cardiol. 2019 Aug 27;74(8):1086-1106. doi: 10.1016/j.jacc.2019.07.014.
J Am Coll Cardiol. 2019.
PMID: 31439219
Free article.
Review.
Despite major improvements in transcatheter aortic valve replacement (TAVR) periprocedural complications in recent years, the occurrence of conduction disturbances has not decreased over time and remains the most frequent complication of the procedure. …
Despite major improvements in transcatheter aortic valve replacement (TAVR) periprocedural complications in rece …