Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1969 1
1976 1
1984 2
1989 1
1990 2
1991 1
1993 2
2000 1
2002 1
2003 1
2005 1
2007 2
2008 4
2010 2
2011 2
2012 1
2013 3
2014 2
2016 1
2017 1
2018 5
2019 5
2021 2
2022 6
2023 5
2024 4

Text availability

Article attribute

Article type

Publication date

Search Results

51 results

Results by year

Filters applied: . Clear all
Page 1
Pilot Trial of Midstream Urine Collection Device Versus Transurethral Catheter in Women With Lower Urinary Tract Symptoms: Practicality of Use in a Clinical Setting, Patient Preferences, and Comparison of Laboratory Findings.
High R, Zhang Y, Virani S, Eggleston K, Kuehl TJ, Bird ET, Danford JM. High R, et al. Female Pelvic Med Reconstr Surg. 2021 Jun 1;27(6):371-376. doi: 10.1097/SPV.0000000000000865. Female Pelvic Med Reconstr Surg. 2021. PMID: 32265404
OBJECTIVES: This study aimed to evaluate successful use of a midstream urine collection device in women with lower urinary tract symptoms and to assess specimen contamination. ...There were no detectable differences in microscopic urinalysis. CONCLUSIONS: The …
OBJECTIVES: This study aimed to evaluate successful use of a midstream urine collection device in women with lower urin …
In-flight urine collection device: efficacy, maintenance, and complications in U-2 pilots.
Von Thesling GH, Coffman CB, Hundemer GL, Stuart RP. Von Thesling GH, et al. Aviat Space Environ Med. 2011 Feb;82(2):116-22. doi: 10.3357/asem.2909.2011. Aviat Space Environ Med. 2011. PMID: 21329026
INTRODUCTION: Urine collection systems for in-flight use have gradually improved over the past 50 yr; however, current management of urine evacuation remains suboptimal. This is a cross-sectional survey-based study on the current urine collection device emplo …
INTRODUCTION: Urine collection systems for in-flight use have gradually improved over the past 50 yr; however, current management of urine e …
Human papillomavirus detection in urine: Effect of a first-void urine collection device and timing of collection.
Pattyn J, Van Keer S, Biesmans S, Ieven M, Vanderborght C, Beyers K, Vankerckhoven V, Bruyndonckx R, Van Damme P, Vorsters A. Pattyn J, et al. J Virol Methods. 2019 Feb;264:23-30. doi: 10.1016/j.jviromet.2018.11.008. Epub 2018 Nov 16. J Virol Methods. 2019. PMID: 30452931 Free article.
The aim of this study was to investigate the potential effect of a first generation FV urine collection device on the detection of HPV DNA and to assess if the concentration of HPV DNA varies between FV urine collected in the morning and those collected later …
The aim of this study was to investigate the potential effect of a first generation FV urine collection device on the d …
A Cross-sectional Pilot Cohort Study Comparing Standard Urine Collection to the Peezy Midstream Device for Research Studies Involving Women.
Southworth E, Hochstedler B, Price TK, Joyce C, Wolfe AJ, Mueller ER. Southworth E, et al. Female Pelvic Med Reconstr Surg. 2019 Mar/Apr;25(2):e28-e33. doi: 10.1097/SPV.0000000000000693. Female Pelvic Med Reconstr Surg. 2019. PMID: 30807432 Free PMC article. Clinical Trial.
CONCLUSIONS: Compared with standard clean catch method, the Peezy urine collection device with and without the castile soap wipe resulted in urine with lower bacterial abundance that was distinct from the periurethra. ...
CONCLUSIONS: Compared with standard clean catch method, the Peezy urine collection device with and without the castile …
Evaluation of the 'Colli-Pee', a first-void urine collection device for self-sampling at home for the detection of sexually transmitted infections, versus a routine clinic-based urine collection in a one-to-one comparison study design: efficacy and acceptability among MSM in Belgium.
De Baetselier I, Smet H, Abdellati S, De Deken B, Cuylaerts V, Reyniers T, Vuylsteke B, Crucitti T. De Baetselier I, et al. BMJ Open. 2019 Apr 3;9(4):e028145. doi: 10.1136/bmjopen-2018-028145. BMJ Open. 2019. PMID: 30948618 Free PMC article.
A novel midstream urine-collection device reduces contamination rates in urine cultures amongst women.
Jackson SR, Dryden M, Gillett P, Kearney P, Weatherall R. Jackson SR, et al. BJU Int. 2005 Aug;96(3):360-4. doi: 10.1111/j.1464-410X.2005.05631.x. BJU Int. 2005. PMID: 16042730 Clinical Trial.
OBJECTIVE: To evaluate a novel urine-collection device (UCD) that automatically collects a midstream urine (MSU) sample, and compare contamination rates to those of the conventional MSU sampling method, as the contamination of urine samples for microbiologica …
OBJECTIVE: To evaluate a novel urine-collection device (UCD) that automatically collects a midstream urine (MSU) sample …
An external urine-collection device for women: a clinical trial.
Pieper B, Cleland V. Pieper B, et al. J ET Nurs. 1993 Mar-Apr;20(2):51-5. doi: 10.1097/00152192-199303000-00010. J ET Nurs. 1993. PMID: 8507726 Clinical Trial.
Many types of condom catheters are available for men, but there are few similar devices for women. For the past 10 years, we have been developing an external urine-collection device for women. This device adheres between the labia to surround the urethra. ...
Many types of condom catheters are available for men, but there are few similar devices for women. For the past 10 years, we have been devel …
Reliable laboratory urinalysis results using a new standardised urine collection device.
Roelofs-Thijssen MA, Schreuder MF, Hogeveen M, van Herwaarden AE. Roelofs-Thijssen MA, et al. Clin Biochem. 2013 Sep;46(13-14):1252-6. doi: 10.1016/j.clinbiochem.2013.04.014. Epub 2013 Apr 26. Clin Biochem. 2013. PMID: 23628593
The objective of this study is to evaluate the applicability of the currently used urine collection pads (gauze compresses) and a new urine collection device (Peespot). DESIGN AND METHODS: We tested the reliability of routine (semi-)quantitative urinalysis re …
The objective of this study is to evaluate the applicability of the currently used urine collection pads (gauze compresses) and a new uri
Clinical evaluation of an external urine collection device for nonambulatory incontinent women.
Johnson DE, O'Reilly JL, Warren JW. Johnson DE, et al. J Urol. 1989 Mar;141(3):535-7. doi: 10.1016/s0022-5347(17)40884-6. J Urol. 1989. PMID: 2918586
For management of urinary incontinence in aged, nonambulatory women use of absorbent products may not prevent decubitus ulcers, while chronic use of indwelling urethral catheters results in bacteriuria and its complications. An effective external urine collection
For management of urinary incontinence in aged, nonambulatory women use of absorbent products may not prevent decubitus ulcers, while chroni …
51 results