Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1902 1
1908 1
1909 1
1920 1
1952 1
1955 1
1957 1
1983 1
1990 1
1991 1
1992 1
1993 1
1996 3
1997 3
1999 3
2000 4
2001 3
2002 4
2003 4
2004 4
2005 5
2006 5
2007 5
2008 7
2009 4
2010 2
2011 8
2012 3
2013 3
2014 11
2015 6
2016 2
2017 3
2018 5
2019 1
2020 2
2021 7
2022 1
2023 3
2024 2

Text availability

Article attribute

Article type

Publication date

Search Results

113 results

Results by year

Filters applied: . Clear all
Page 1
Risk Factors Associated With Femoral Ring Allograft Breakage in ALIF.
Philipp T, Radoslovich SS, Yoo JU. Philipp T, et al. Global Spine J. 2021 Jan;11(1):57-62. doi: 10.1177/2192568219890294. Epub 2019 Nov 22. Global Spine J. 2021. PMID: 32875836 Free PMC article.
OBJECTIVES: To identify the incidence of, and variables correlated with, femoral ring allograft (FRA) fracture following anterior lumbar interbody fusion (ALIF). ...
OBJECTIVES: To identify the incidence of, and variables correlated with, femoral ring allograft (FRA) fracture following anter …
Femoral ring versus fibular strut allografts in anterior lumbar interbody arthrodesis. A biomechanical analysis.
Siff TE, Kamaric E, Noble PC, Esses SI. Siff TE, et al. Spine (Phila Pa 1976). 1999 Apr 1;24(7):659-65. doi: 10.1097/00007632-199904010-00009. Spine (Phila Pa 1976). 1999. PMID: 10209794
STUDY DESIGN: A comparison between femoral ring and fibular strut allografts in anterior lumbar interbody arthrodesis, as assessed by biomechanical analysis. OBJECTIVES: To assess the difference in stability and rigidity provided by the femoral ring al …
STUDY DESIGN: A comparison between femoral ring and fibular strut allografts in anterior lumbar interbody arthrodesis, as asse …
[Femoral hernias: repair techniques].
Mathonnet M, Mehinto D. Mathonnet M, et al. J Chir (Paris). 2007 Sep-Oct;144 Spec No 4:5S15-8. J Chir (Paris). 2007. PMID: 18065913 Review. French.
This is predominantly a female disorder. Given the configuration of the femoral ring itself, these hernias are difficult to diagnose and carry a high risk of strangulation (risk multiplied by 10) and visceral pain. ...
This is predominantly a female disorder. Given the configuration of the femoral ring itself, these hernias are difficult to di …
Biological cages.
Janssen ME, Nguyen C, Beckham R, Larson A. Janssen ME, et al. Eur Spine J. 2000 Feb;9 Suppl 1(Suppl 1):S102-9. doi: 10.1007/pl00008315. Eur Spine J. 2000. PMID: 10766065 Free PMC article. Clinical Trial.
The ability to radiographically assess the "biology" of bone incorporation in these mechanical (metal) spacers is an inherent limitation. The femoral ring allograft (FRA) and posterior lumbar interbody fusion (PLIF) spacers have been developed as biological cages th …
The ability to radiographically assess the "biology" of bone incorporation in these mechanical (metal) spacers is an inherent limitation. Th …
Femoral ring allograft for anterior cervical interbody fusion: technical note.
Shapiro S, Bindal R. Shapiro S, et al. Neurosurgery. 2000 Dec;47(6):1457-9. Neurosurgery. 2000. PMID: 11126920
With the knowledge that cortically dense allografts collapse less with time, new machined femoral ring allografts were developed for anterior cervical fusion after anterior cervical discectomy. We describe the system and the technique for placement. METHODS: The …
With the knowledge that cortically dense allografts collapse less with time, new machined femoral ring allografts were develop …
Use of allograft femoral rings for spinal deformity in adults.
Kleinstueck FS, Hu SS, Bradford DS. Kleinstueck FS, et al. Clin Orthop Relat Res. 2002 Jan;(394):84-91. doi: 10.1097/00003086-200201000-00010. Clin Orthop Relat Res. 2002. PMID: 11795755 Review.
The literature and the authors' experience support the use of femoral ring allograft as a structural and biologic compatible implant to reconstruct anterior column defects. ...No long-term studies exist that show that cages are superior in correction of deformity. …
The literature and the authors' experience support the use of femoral ring allograft as a structural and biologic compatible i …
Preperitoneal femoral hernioplasty: an "umbrella" technique.
Kang JS, Qiao F, Nie L, Wang Y, He SW, Wu B. Kang JS, et al. Hernia. 2015 Oct;19(5):805-8. doi: 10.1007/s10029-014-1273-1. Epub 2014 Jun 14. Hernia. 2015. PMID: 24927966
., the myopectineal orifice, with the plug flattened like an "umbrella", above the femoral ring but not to fill the femoral ring. RESULTS: All cases receiving preperitoneal tension-free hernioplasty had a smooth recovery. ...
., the myopectineal orifice, with the plug flattened like an "umbrella", above the femoral ring but not to fill the femoral
The need for structural allograft biomechanical guidelines.
Kawaguchi S, Hart RA. Kawaguchi S, et al. J Am Acad Orthop Surg. 2015 Feb;23(2):119-25. doi: 10.5435/JAAOS-D-14-00263. J Am Acad Orthop Surg. 2015. PMID: 25624364 Review.
Given the relative lack of data on which to base reasonable screening standards, we undertook basic biomechanical evaluation of one source of structural bone allograft, the femoral ring. Of our tested parameters, the minimum and maximum cortical wall thicknesses of …
Given the relative lack of data on which to base reasonable screening standards, we undertook basic biomechanical evaluation of one source o …
Preperitoneal approach for femoral hernia repair.
Družijanić N, Sršen D, Pogorelić Z, Mijaljica G, Juričić J, Perko Z, Kraljević D, Krnić D, Bilan K. Družijanić N, et al. Hepatogastroenterology. 2011 Sep-Oct;58(110-111):1450-4. doi: 10.5754/hge10117. Hepatogastroenterology. 2011. PMID: 22086683
Once the peritoneum is sutured, the iliopubic tract and Cooper's ligament are bridged with two or three sutures in the medial portion of the femoral ring. RESULTS: From 1998 to 2008, 94 patients were treated for femoral hernia using the preperitoneal approach. ...
Once the peritoneum is sutured, the iliopubic tract and Cooper's ligament are bridged with two or three sutures in the medial portion of the …
Role of femoral ring allograft in anterior interbody fusion of the spine.
Chotivichit A, Fujita T, Wong TH, Kostuik JP, Sieber AN. Chotivichit A, et al. J Orthop Surg (Hong Kong). 2001 Dec;9(2):1-5. doi: 10.1177/230949900100900202. J Orthop Surg (Hong Kong). 2001. PMID: 12118123 Free article.
A review was carried out on 59 patients (10 males and 49 females) who had anterior interbody fusion performed with femoral ring allograft packed with autograft bone chips with a minimum follow up of 2 years. ...Three patients had persistence of radiolucent line at o …
A review was carried out on 59 patients (10 males and 49 females) who had anterior interbody fusion performed with femoral ring
113 results