Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1998 1
2019 1
2021 1
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

4 results

Results by year

Filters applied: . Clear all
Quoted phrase not found in phrase index: "medial proper plantar digital artery of second toe"
Page 1
The modified second toe flap technique based on the dorsal digital artery of the toe in finger pulp reconstruction.
Li J, Wu H, Zhang Y, Jin G, Wang K, Zhang G, Ju J. Li J, et al. Microsurgery. 2023 Sep;43(6):580-587. doi: 10.1002/micr.31073. Epub 2023 Jun 12. Microsurgery. 2023. PMID: 37309237
It mainly carries the proper plantar digital artery and nerve. But the donor site morbidity and arterial injury are common. The report retrospectively evaluated the clinical outcomes of the second toe free medial flap based …
It mainly carries the proper plantar digital artery and nerve. But the donor site morbidity and arterial
Anatomical and Clinical Comparison of Small Free Flaps for Repairing Finger Skin Defects.
He B, Liu J, Pang V, Zhu L, Huang Y, Wang Z, Xu Y, Zhu Z, Wang K. He B, et al. Ann Plast Surg. 2019 Dec;83(6):664-669. doi: 10.1097/SAP.0000000000001933. Ann Plast Surg. 2019. PMID: 31403479
From January 2006 to December 2018, we investigated the number and diameter of proximal digital artery perforators, medial plantar artery perforators, and peroneal proper plantar digital arteries of the hallux by diss …
From January 2006 to December 2018, we investigated the number and diameter of proximal digital artery perforators, medial
Using 320-detector row computed tomography angiography to investigate the arterial anatomy of the toe flaps on living humans.
Nguyen VT, Lam K, Le VD. Nguyen VT, et al. Surg Radiol Anat. 2021 Oct;43(10):1711-1719. doi: 10.1007/s00276-021-02793-8. Epub 2021 Jul 5. Surg Radiol Anat. 2021. PMID: 34226966
PURPOSE: Using 320-detector row computed tomography angiography (320-CTA) to investigate the arterial supply for the toe flaps, namely the anatomical characteristics of the dorsalis pedis artery (DPA), the first dorsal metatarsal artery (FDMA), and the …
PURPOSE: Using 320-detector row computed tomography angiography (320-CTA) to investigate the arterial supply for the toe flaps …
Microarterial anatomy of the lesser toe proximal interphalangeal joints.
Chen YG, Cook PA, McClinton MA, Espinosa RA, Wilgis EF. Chen YG, et al. J Hand Surg Am. 1998 Mar;23(2):256-60. doi: 10.1016/s0363-5023(98)80123-8. J Hand Surg Am. 1998. PMID: 9556265
The diameter of the medial proper digital arteries (range, 1.2-1.26 mm) was larger than the lateral proper digital arteries (range, 0.66-0.99 mm). The proper digital arteries of the lesser toes provide t …
The diameter of the medial proper digital arteries (range, 1.2-1.26 mm) was larger than the lateral proper