Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1979 1
1984 1
1987 1
1989 1
1990 1
1992 1
1993 3
1995 2
1996 6
1997 5
1998 3
1999 9
2000 1
2001 5
2002 5
2003 5
2004 9
2005 10
2006 13
2007 7
2008 11
2009 8
2010 8
2011 12
2012 17
2013 20
2014 15
2015 13
2016 15
2017 21
2018 16
2019 18
2020 22
2021 24
2022 18
2023 14
2024 6

Text availability

Article attribute

Article type

Publication date

Search Results

295 results

Results by year

Filters applied: . Clear all
The following terms were ignored: %, %, %, %
The following terms were not found in PubMed: 22Space, 5BMeSH
Page 1
Low-Concentration Atropine for Myopia Progression (LAMP) Study: A Randomized, Double-Blinded, Placebo-Controlled Trial of 0.05%, 0.025%, and 0.01% Atropine Eye Drops in Myopia Control.
Yam JC, Jiang Y, Tang SM, Law AKP, Chan JJ, Wong E, Ko ST, Young AL, Tham CC, Chen LJ, Pang CP. Yam JC, et al. Ophthalmology. 2019 Jan;126(1):113-124. doi: 10.1016/j.ophtha.2018.05.029. Epub 2018 Jul 6. Ophthalmology. 2019. PMID: 30514630 Clinical Trial.

RESULTS: After 1 year, the mean SE change was -0.270.61 D, -0.460.45 D, -0.590.61 D, and -0.810.53 D in the 0.05%, 0.025%, and 0.01% atropine groups, and placebo groups, respectively (P < 0.001), with a respective mean increase in AL of 0.200.25 mm, 0.290.20 mm, 0.360.29 mm, a

RESULTS: After 1 year, the mean SE change was -0.270.61 D, -0.460.45 D, -0.590.61 D, and -0.810.53 D in the 0.05%, 0.025%, and 0.01% atropin …
Lens induced aniso-accommodation.
Marran L, Schor CM. Marran L, et al. Vision Res. 1998 Nov;38(22):3601-19. doi: 10.1016/s0042-6989(98)00064-9. Vision Res. 1998. PMID: 9893793 Free article.
Recent developments in the intraocular lens formulae: An update.
Kothari SS, Reddy JC. Kothari SS, et al. Semin Ophthalmol. 2023 Feb;38(2):143-150. doi: 10.1080/08820538.2022.2094712. Epub 2022 Jul 1. Semin Ophthalmol. 2023. PMID: 35776680 Review.
They were compared according to the reported median absolute error, mean absolute error and percentage of eyes within 0.5D. CONCLUSION: The Kane formula and Barrett Universal-II formula performed better than other formulas over the entire axial length (AL) spectrum. In the …
They were compared according to the reported median absolute error, mean absolute error and percentage of eyes within 0.5D. CONCLUSIO …
Developing dynamic defocus curve for evaluating dynamic vision accommodative function.
Wu T, Wang Y, Wei S, Guo Y, Li X. Wu T, et al. BMC Ophthalmol. 2022 Mar 5;22(1):106. doi: 10.1186/s12886-022-02335-9. BMC Ophthalmol. 2022. PMID: 35248018 Free PMC article.
Meanwhile, DVA was positively correlated with PRA at 0D, -1.0D, -1.5D, -2.5D and -3.0D (p<0.05) and with NRA-PRA at 0D, -1.0D, -1.5D, -2.0D and -2.5D (p<0.05). Multiple factor regression analysis indicated that CDVAc (0D ~ -3.5D) and SVA ( …
Meanwhile, DVA was positively correlated with PRA at 0D, -1.0D, -1.5D, -2.5D and -3.0D (p<0.05) and with NRA-PRA at 0D, -1. …
Perceptual impact of astigmatism induction in presbyopes.
Benedi-Garcia C, Velasco-Ocana M, Dorronsoro C, Pascual D, Hernandez M, Marin G, Marcos S. Benedi-Garcia C, et al. Vision Res. 2019 Dec;165:143-151. doi: 10.1016/j.visres.2019.10.008. Epub 2019 Nov 18. Vision Res. 2019. PMID: 31751899 Free article.
Measurements were performed using a custom-developed Adaptive Optics system, which allowed correction of high order aberrations and induction of astigmatism (0.5, 1, 1.5 and 2.0 D; axis: 180, 45 and 22.5). Upon induction of astigmatism, best focus shifted towards negative …
Measurements were performed using a custom-developed Adaptive Optics system, which allowed correction of high order aberrations and inductio …
Is Peripheral Motion Detection Affected by Myopia?
Wei J, Kong D, Yu X, Wei L, Xiong Y, Yang A, Drobe B, Bao J, Zhou J, Gao Y, He Z. Wei J, et al. Front Neurosci. 2021 Jun 7;15:683153. doi: 10.3389/fnins.2021.683153. eCollection 2021. Front Neurosci. 2021. PMID: 34163327 Free PMC article.
PURPOSE: The current study was to investigate whether myopia affected peripheral motion detection and whether the potential effect interacted with spatial frequency, motion speed, or eccentricity. METHODS: Seventeen young adults aged 22-26 years participated in the study. …
PURPOSE: The current study was to investigate whether myopia affected peripheral motion detection and whether the potential effect interacte …
Comparing New York Heart Association Class and Patient-Reported Outcomes Among Patients Hospitalized for Heart Failure.
Cosiano MF, Vista A, Sun JL, Alhanti B, Harrington J, Butler J, Starling RC, Mentz RJ, Greene SJ. Cosiano MF, et al. Circ Heart Fail. 2023 Jan;16(1):e010107. doi: 10.1161/CIRCHEARTFAILURE.122.010107. Epub 2022 Oct 31. Circ Heart Fail. 2023. PMID: 36314126 Free article. Clinical Trial.
RESULTS: Among 5741 patients, concordance, minor discordance, and moderate-severe discordance between NYHA class and EQ-5D utility index occurred in 22%, 40%, and 38% of patients, respectively. For NYHA class and EQ-5D visual analog scale, this categorization …
RESULTS: Among 5741 patients, concordance, minor discordance, and moderate-severe discordance between NYHA class and EQ-5D utility in …
First trans-diagnostic experiences with a novel micro-choice based concentrated group rehabilitation for patients with low back pain, long COVID, and type 2 diabetes: a pilot study.
Kvale G, Søfteland E, Jürgensen M, Wilhelmsen-Langeland A, Haugstvedt A, Hystad SW, Ødegaard-Olsen ØT, Aarli BB, Rykken S, Frisk B. Kvale G, et al. BMC Med. 2024 Jan 11;22(1):12. doi: 10.1186/s12916-023-03237-3. BMC Med. 2024. PMID: 38200486 Free PMC article. Clinical Trial.
Client Satisfaction Questionnaire (CSQ-8)) (1 week), Work and Social Adjustment Scale (WSAS), Brief Illness Perception Questionnaire (BIPQ), and self-rated health status (EQ-5D-5L) were registered at baseline and 3-month follow-up. ...WSAS improved significantly fro …
Client Satisfaction Questionnaire (CSQ-8)) (1 week), Work and Social Adjustment Scale (WSAS), Brief Illness Perception Questionnaire …
Four-year visual outcomes and optical quality of SMILE and implantable collamer lens V4c (EVO-ICL) implantation for high myopia: a retrospective study.
Luo W, Aruma A, Li M, Wang J, Xie J, Xiao X, Shen Y, Niu L, Wang X, Zhou X. Luo W, et al. BMC Ophthalmol. 2023 Jul 31;23(1):341. doi: 10.1186/s12886-023-03050-9. BMC Ophthalmol. 2023. PMID: 37525155 Free PMC article.
All patients were then prospectively examined at a four-year follow-up for routine postoperative examinations, higher-order ocular aberrations, retinal image quality and a questionnaire. RESULTS: The safety indexes were 1.15 0.14 and 1.22 0.21 (P = 0.36) for the SMILE and …
All patients were then prospectively examined at a four-year follow-up for routine postoperative examinations, higher-order ocular aberratio …
Sensory Profiles in Patients with Low Back Pain with and Without Radiculopathy.
Reimer M, Witthöft J, Greinacher J, Sachau J, Forstenpointner J, Hüllemann P, Binder A, Gierthmühlen J, Baron R. Reimer M, et al. Pain Med. 2023 Mar 1;24(3):306-315. doi: 10.1093/pm/pnac129. Pain Med. 2023. PMID: 36111863
METHODS: Patients with LBP (n = 54) were assessed with quantitative sensory testing in the area of LBP and, in cases of RAD, additionally in the area of projecting pain. Questionnaires (PainDETECT, EuroQol-5D, Medical Outcomes Study Sleep Scale, Hannover Functional Ability …
METHODS: Patients with LBP (n = 54) were assessed with quantitative sensory testing in the area of LBP and, in cases of RAD, additionally in …
295 results