Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2003 1
2010 1
2011 2
2013 1
2014 1
2016 1
2017 3
2018 7
2019 3
2020 3
2021 4
2022 6
2023 4
2024 3

Text availability

Article attribute

Article type

Publication date

Search Results

34 results

Results by year

Filters applied: . Clear all
Page 1
Did you mean adeva (272 results)?
Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial.
Tan HS, Nagarajan S, Chan JJI, Tan CW, Sultana R, Sia ATH, Sng BL. Tan HS, et al. BMC Anesthesiol. 2023 Jan 26;23(1):33. doi: 10.1186/s12871-023-01992-7. BMC Anesthesiol. 2023. PMID: 36703120 Free PMC article. Clinical Trial.
A novel double intravenous vasopressor automated (DIVA) system reduces hypotension compared to standard care, and was subsequently modified to an advanced-DIVA (ADIVA) system. The primary objective was to compare ADIVA versus DIVA on incidence of hypotension (systol …
A novel double intravenous vasopressor automated (DIVA) system reduces hypotension compared to standard care, and was subsequently modified …
HF etching of CAD/CAM materials: influence of HF concentration and etching time on shear bond strength.
Straface A, Rupp L, Gintaute A, Fischer J, Zitzmann NU, Rohr N. Straface A, et al. Head Face Med. 2019 Aug 8;15(1):21. doi: 10.1186/s13005-019-0206-8. Head Face Med. 2019. PMID: 31395069 Free PMC article.
METHODS: SBS of two adhesive (Panavia V5, Kuraray, [PV5]; Vita Adiva F-Cem, Vita Zahnfabrik, [VAF]) and two self-adhesive (RelyX Unicem 2 Automix, 3 M Espe, [RUN]; Vita Adiva S-Cem, Vita, [VAS]) cements to four different CAD/CAM materials (Vitablocs Mark II, Vita, [ …
METHODS: SBS of two adhesive (Panavia V5, Kuraray, [PV5]; Vita Adiva F-Cem, Vita Zahnfabrik, [VAF]) and two self-adhesive (RelyX Unic …
Fracture load of zirconia implant supported CAD/CAM resin crowns and mechanical properties of restorative material and cement.
Rohr N, Märtin S, Fischer J. Rohr N, et al. J Prosthodont Res. 2021 Oct 15;65(4):502-508. doi: 10.2186/jpr.JPR_D_20_00051. Epub 2021 Apr 9. J Prosthodont Res. 2021. PMID: 33840705 Free article.
Purpose To test if resin CAD/CAM materials should be considered for zirconia implants and how their mechanical properties affect the fracture load.Methods Fracture load of molar crowns of CAD/CAM materials (VITA CAD-Temp [CT], Cerasmart [CS], Lava Ultimate [LU], Pekkton Ivory [PK …
Purpose To test if resin CAD/CAM materials should be considered for zirconia implants and how their mechanical properties affect the fractur …
An advanced double intravenous vasopressor automated system to treat hypotension during spinal anaesthesia for caesarean section: A pilot study.
Nagarajan S, Chan JJI, Tan CW, Al-Hashim ZGA, Sultana R, Sia ATH, Sng BL. Nagarajan S, et al. Eur J Anaesthesiol. 2022 Jan 1;39(1):42-49. doi: 10.1097/EJA.0000000000001496. Eur J Anaesthesiol. 2022. PMID: 33831901
We developed a novel advanced double intravenous vasopressor automated system (ADIVA) by using a continuous blood pressure and heart rate monitor. ...OBJECTIVE: The aim of this pilot study was to investigate the feasibility of the ADIVA algorithm. DESIGN: A prospect …
We developed a novel advanced double intravenous vasopressor automated system (ADIVA) by using a continuous blood pressure and heart …
Chewing simulation of zirconia implant supported restorations.
Rohr N, Balmer M, Müller JA, Märtin S, Fischer J. Rohr N, et al. J Prosthodont Res. 2019 Jul;63(3):361-367. doi: 10.1016/j.jpor.2019.02.002. Epub 2019 Mar 8. J Prosthodont Res. 2019. PMID: 30853580
Monolithic zirconia (Vita YZ [YZ] with RelyX Unicem 2 Automix [RUN], polymer-infiltrated ceramic (Vita Enamic [VE]) with Vita Adiva F-Cem [VAF] and acrylate polymer (CAD Temp [CT]) with RelyX Ultimate [RUL]. ...
Monolithic zirconia (Vita YZ [YZ] with RelyX Unicem 2 Automix [RUN], polymer-infiltrated ceramic (Vita Enamic [VE]) with Vita Adiva F …
Biofilm formation on restorative materials and resin composite cements.
Astasov-Frauenhoffer M, Glauser S, Fischer J, Schmidli F, Waltimo T, Rohr N. Astasov-Frauenhoffer M, et al. Dent Mater. 2018 Nov;34(11):1702-1709. doi: 10.1016/j.dental.2018.08.300. Epub 2018 Sep 13. Dent Mater. 2018. PMID: 30220506
METHODS: Disks made of zirconia (Vita YZ [YZ]), polymer-infiltrated ceramic (Vita Enamic [VE]), acrylate polymer (Vita CAD-Temp [CT]), self-adhesive cement (RelyX Unicem 2 Automix [RUN]) and of two different adhesive cements (RelyX Ulimate [RUL] and Vita Adiva F-Cem [VAF]) …
METHODS: Disks made of zirconia (Vita YZ [YZ]), polymer-infiltrated ceramic (Vita Enamic [VE]), acrylate polymer (Vita CAD-Temp [CT]), self- …
Influence of cement type and ceramic primer on retention of polymer-infiltrated ceramic crowns to a one-piece zirconia implant.
Rohr N, Brunner S, Märtin S, Fischer J. Rohr N, et al. J Prosthet Dent. 2018 Jan;119(1):138-145. doi: 10.1016/j.prosdent.2017.02.002. Epub 2017 Apr 28. J Prosthet Dent. 2018. PMID: 28461047 Free article.
MATERIAL AND METHODS: The retention test was performed using 100 polymer-infiltrated ceramic crowns (Vita Enamic) and zirconia implants (ceramic.implant CI) The crowns were cemented with either interim cement (Harvard Implant semipermanent, Temp Bond), glass-ionomer cement (Ketac …
MATERIAL AND METHODS: The retention test was performed using 100 polymer-infiltrated ceramic crowns (Vita Enamic) and zirconia implants (cer …
Correlations between fracture load of zirconia implant supported single crowns and mechanical properties of restorative material and cement.
Rohr N, Märtin S, Fischer J. Rohr N, et al. Dent Mater J. 2018 Mar 30;37(2):222-228. doi: 10.4012/dmj.2017-111. Epub 2017 Nov 23. Dent Mater J. 2018. PMID: 29176305 Free article.
Purpose of this study was to evaluate the fracture load of different zirconia implant supported monolithic crown materials (zirconia, alumina, lithium disilicate, feldspar ceramic and polymer-infiltrated ceramic) cemented with various cements (Harvard LuteCem SE, Harvard Implant …
Purpose of this study was to evaluate the fracture load of different zirconia implant supported monolithic crown materials (zirconia, alumin …
Influence of Ambient Temperature and Light-curing Moment on Polymerization Shrinkage and Strength of Resin Composite Cements.
Rohr N, Müller JA, Fischer J. Rohr N, et al. Oper Dent. 2018 Nov/Dec;43(6):619-630. doi: 10.2341/17-085-L. Epub 2018 Aug 24. Oper Dent. 2018. PMID: 30142041
METHODS AND MATERIALS: Polymerization shrinkage of seven resin composite cements (Multilink Automix, Multilink Speed Cem, RelyX Ultimate, RelyX Unicem 2 Automix, Panavia V5, Panavia SA plus, VITA Adiva F-Cem) was measured at ambient temperatures of 23C and 37C. ...Highest …
METHODS AND MATERIALS: Polymerization shrinkage of seven resin composite cements (Multilink Automix, Multilink Speed Cem, RelyX Ultimate, Re …
34 results