Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1966 1
1967 1
1968 1
1971 1
1975 8
1976 12
1977 10
1978 4
1979 9
1980 6
1981 11
1982 8
1983 15
1984 11
1985 25
1986 17
1987 25
1988 15
1989 24
1990 21
1991 21
1992 18
1993 22
1994 22
1995 16
1996 22
1997 19
1998 28
1999 28
2000 37
2001 57
2002 40
2003 57
2004 55
2005 64
2006 46
2007 39
2008 43
2009 55
2010 39
2011 51
2012 45
2013 57
2014 44
2015 56
2016 33
2017 26
2018 31
2019 40
2020 42
2021 50
2022 33
2023 24
2024 4

Text availability

Article attribute

Article type

Publication date

Search Results

1,378 results

Results by year

Filters applied: . Clear all
Page 1
Showing results for u ergs
Your search for u-ergo retrieved no results
Novel estrogen-responsive genes (ERGs) for the evaluation of estrogenic activity.
Nishi K, Fu W, Kiyama R. Nishi K, et al. PLoS One. 2022 Aug 17;17(8):e0273164. doi: 10.1371/journal.pone.0273164. eCollection 2022. PLoS One. 2022. PMID: 35976950 Free PMC article.
Estrogen action is mediated by various genes, including estrogen-responsive genes (ERGs). ERGs have been used as reporter-genes and markers for gene expression. ...However, the quality of ERGs has not been extensively examined. Here, we obtained a set of 300 …
Estrogen action is mediated by various genes, including estrogen-responsive genes (ERGs). ERGs have been used as reporter-gene …
Modulation of flash ERGs by dynamic backgrounds.
Kremers J, Aher AJ, Huchzermeyer C. Kremers J, et al. Doc Ophthalmol. 2023 Feb;146(1):33-51. doi: 10.1007/s10633-022-09902-x. Epub 2022 Oct 20. Doc Ophthalmol. 2023. PMID: 36266494 Free PMC article.
We studied the influence of sinusoidally modulating backgrounds on flash ERGs and the relationship between the ERG components' amplitudes and the momentary Weber fraction of the flash stimulus. ...RESULTS: The flash ERGs were strongly modulated by the backgrounds pa …
We studied the influence of sinusoidally modulating backgrounds on flash ERGs and the relationship between the ERG components' amplit …
Combining single-cell sequencing and spatial transcriptome sequencing to identify exosome-related features of glioblastoma and constructing a prognostic model to identify BARD1 as a potential therapeutic target for GBM patients.
Zhao S, Wang Q, Ni K, Zhang P, Liu Y, Xie J, Ji W, Cheng C, Zhou Q. Zhao S, et al. Front Immunol. 2023 Aug 31;14:1263329. doi: 10.3389/fimmu.2023.1263329. eCollection 2023. Front Immunol. 2023. PMID: 37727789 Free PMC article.
After data integration, cell clustering, and annotation, five algorithms were used to calculate scores for exosome-related genes(ERGs). Cell trajectory analysis and intercellular communication analysis were performed to explore exosome-related communication patterns. ...Sp …
After data integration, cell clustering, and annotation, five algorithms were used to calculate scores for exosome-related genes(ERGs
Occult macular dystrophy.
Miyake Y, Tsunoda K. Miyake Y, et al. Jpn J Ophthalmol. 2015 Mar;59(2):71-80. doi: 10.1007/s10384-015-0371-7. Epub 2015 Feb 10. Jpn J Ophthalmol. 2015. PMID: 25665791 Review.
Patients with OMD are characterized by a progressive decrease of visual acuity but have normal fundus and fluorescein angiograms with both the rod and cone components of the full-field electroretinograms (ERGs) essentially normal. However, the focal macular ERGs and …
Patients with OMD are characterized by a progressive decrease of visual acuity but have normal fundus and fluorescein angiograms with both t …
The spatial distribution of ERGs reflecting luminance and L-/M-cone-opponent signals.
Vidal KS, Aher AJ, Ventura DF, Kremers J. Vidal KS, et al. Doc Ophthalmol. 2021 Jun;142(3):329-342. doi: 10.1007/s10633-020-09807-7. Epub 2021 Jan 28. Doc Ophthalmol. 2021. PMID: 33506285 Free PMC article.
Two temporal frequencies of the stimuli were employed: 12 Hz to record ERGs that reflect L-/M-cone-opponent signal and 36 Hz for recording ERG signals sensitive to stimulus luminance. ...CONCLUSIONS: In the present study, it was found that retinal eccentricity and directio …
Two temporal frequencies of the stimuli were employed: 12 Hz to record ERGs that reflect L-/M-cone-opponent signal and 36 Hz for reco …
Qualitative and quantitative comparison of ERGs with contact lens and adhesive skin electrodes.
Chen D, Greenstein VC, Brodie SE. Chen D, et al. Doc Ophthalmol. 2022 Jun;144(3):203-215. doi: 10.1007/s10633-022-09868-w. Epub 2022 Mar 18. Doc Ophthalmol. 2022. PMID: 35304683
PURPOSE: Traditional ERGs recorded using corneal electrodes can be difficult for some patients to tolerate. ...METHODS: 89 subjects were included; all were referred for full-field ERG testing for multiple indications. ERGs (obtained according to ISCEV standards) wer …
PURPOSE: Traditional ERGs recorded using corneal electrodes can be difficult for some patients to tolerate. ...METHODS: 89 subjects w …
Temporal Properties of Flicker ERGs in Rabbit Model of Retinitis Pigmentosa.
Okado S, Ueno S, Kominami T, Nakanishi A, Inooka D, Sayo A, Kondo M, Terasaki H. Okado S, et al. Invest Ophthalmol Vis Sci. 2017 Oct 1;58(12):5518-5525. doi: 10.1167/iovs.17-22332. Invest Ophthalmol Vis Sci. 2017. PMID: 29075762
PURPOSE: We determined the effects of a remodeled inner retina on the flicker electroretinograms (ERGs) in a rabbit eye at an advanced stage of inherited retinal degeneration. ...Evaluations of the flicker ERGs in RP eyes must be done with careful considerations of …
PURPOSE: We determined the effects of a remodeled inner retina on the flicker electroretinograms (ERGs) in a rabbit eye at an advance …
Multifocal rod electroretinograms.
Hood DC, Wladis EJ, Shady S, Holopigian K, Li J, Seiple W. Hood DC, et al. Invest Ophthalmol Vis Sci. 1998 Jun;39(7):1152-62. Invest Ophthalmol Vis Sci. 1998. PMID: 9620074
PURPOSE: To assess the feasibility of obtaining reliable multifocal rod electroretinograms (ERGS) and to compare them to full-field ERGs. METHODS: Multifocal rod ERGs were recorded using a stimulus array of 61 hexagons. ...Flash intensities varied from -1 to …
PURPOSE: To assess the feasibility of obtaining reliable multifocal rod electroretinograms (ERGS) and to compare them to full-field …
Pattern Onset ERGs and VEPs Produced by Patterns Arising From Light Increment and Decrement.
Fritsch DM, Sowden JC, Thompson DA. Fritsch DM, et al. Invest Ophthalmol Vis Sci. 2018 Jan 1;59(1):94-99. doi: 10.1167/iovs.17-22984. Invest Ophthalmol Vis Sci. 2018. PMID: 29332121 Free article.
PURPOSE: Our aim was to elaborate how on and off signals contribute to pattern ERGs and pattern visual evoked potentials (VEPs) by using pedestal patterns arising from incremental and decremental onset stimulation. ...CONCLUSIONS: In healthy individuals, the early componen …
PURPOSE: Our aim was to elaborate how on and off signals contribute to pattern ERGs and pattern visual evoked potentials (VEPs) by us …
Supernormal Flicker ERGs in Eyes With Central Retinal Vein Occlusion: Clinical Characteristics, Prognosis, and Effects of Anti-VEGF Agent.
Miyata R, Kondo M, Kato K, Sugimoto M, Matsubara H, Ikesugi K, Ueno S, Yasuda S, Terasaki H. Miyata R, et al. Invest Ophthalmol Vis Sci. 2018 Dec 3;59(15):5854-5861. doi: 10.1167/iovs.18-25087. Invest Ophthalmol Vis Sci. 2018. PMID: 30550616
METHODS: Forty-eight eyes of 48 patients with a CRVO were studied. Flicker ERGs were recorded from fully dilated eyes with the RETeval system. ...The CRVO eyes with supernormal flicker ERGs had a significant amplitude reduction after a single injection of an anti-VE …
METHODS: Forty-eight eyes of 48 patients with a CRVO were studied. Flicker ERGs were recorded from fully dilated eyes with the RETeva …
1,378 results